Authorized ABB Power Distribution Wholesaler for British Columbia | Qualified Contractors May Be Eligible for Additional ABB Pricing Programs
Products: 114 of 14
        • Ortech
          Wall Mount Occupancy Sensor Switch · 120V AC · 800W Tungsten / 800VA Ballast · Ortech DWOS
          DWOS
          29   – Loyalty Rewards
          • $29.85
          Available to Order | Typically Arrives in 1 - 3 Weeks
          Click the image to back order this item from the product page
          • Edmonton Stock: 3
              Click the image to back order this item from the product page
              • Edmonton Stock: 1
                  Click the image to back order this item from the product page
                  • Edmonton Stock: 2
                      Click the image to back order this item from the product page
                      • Stock in BC
                          Satco Lighting
                          Add-On Motion Sensor · 120V · LED Rated, White · Satco Lighting 86-500
                          86-500
                          27   – Loyalty Rewards
                          • $27.44
                          7 Stocked In Coquitlam As of May 26, 2026
                          Click the image to back order this item from the product page
                              • Intermatic
                                Occupancy Sensor Switch · 120V · PIR 150° Coverage, No Neutral Required, White · Intermatic IOS-DPBIMF-WH
                                IOS-DPBIMF-WH
                                50   – Loyalty Rewards
                                • $50.55
                                Available to Order | Typically Arrives in 1 - 3 Weeks From Ontario Factory Warehouse
                                Click the image to back order this item from the product page
                                    • Intermatic
                                      Occupancy/Vacancy Sensor · 180° Coverage · Dual Technology PIR/Ultrasonic · Intermatic IOS-DOV-DT-WH
                                      IOS-DOV-DT-WH
                                      286   – Loyalty Rewards
                                      • $286.78
                                      Available to Order | Typically Arrives in 1 - 3 Weeks From Ontario Factory Warehouse
                                      Click the image to back order this item from the product page
                                          • Intermatic
                                            In-Wall Vacancy Sensor · 120V · PIR 180° 1200 sq ft Coverage · No Neutral Required · Intermatic IOS-DOV-WH
                                            IOS-DOV-WH
                                            83   – Loyalty Rewards
                                            • $83.51
                                            Available to Order | Typically Arrives in 1 - 3 Weeks From Ontario Factory Warehouse
                                            Click the image to back order this item from the product page
                                                • Intermatic
                                                  High-Bay Occupancy Sensor · 120/277V · PIR 360° Coverage · Intermatic IOS-HB-U
                                                  IOS-HB-U
                                                  172   – Loyalty Rewards
                                                  • $172.83
                                                  Available to Order | Typically Arrives in 1 - 3 Weeks From Ontario Factory Warehouse
                                                  Click the image to back order this item from the product page
                                                      • Intermatic
                                                        Ceiling Mount Occupancy Sensor · 24 VDC Low Voltage · 360° PIR Coverage · Intermatic IOS-CMP-LV
                                                        IOS-CMP-LV
                                                        148   – Loyalty Rewards
                                                        • $148.17
                                                        Available to Order | Typically Arrives in 1 - 3 Weeks From Ontario Factory Warehouse
                                                        Click the image to back order this item from the product page
                                                            • Intermatic
                                                              Low-Voltage Power Pack · 120-277 VAC Input, 24 VDC Output · Powers Up to 6 Sensors · Intermatic IOS-PP24
                                                              IOS-PP24
                                                              123   – Loyalty Rewards
                                                              • $123.47
                                                              Available to Order | Typically Arrives in 1 - 3 Weeks From Ontario Factory Warehouse
                                                              Click the image to back order this item from the product page
                                                                  • Click the image to back order this item from the product page
                                                                        • Click the image to back order this item from the product page
                                                                          • Stock in Calgary
                                                                              Click the image to back order this item from the product page

                                                                            Quick Decision Summary

                                                                            • Choose occupancy sensors when automatic-on operation is acceptable and vacancy sensors when manual-on is preferred for energy savings and nuisance reduction.
                                                                            • Match the sensor to the space: wall switch sensors for small rooms, ceiling sensors for open areas, and daylight sensors where perimeter daylight harvesting is part of the control strategy.
                                                                            • Check load type before ordering. LED drivers, electronic ballasts, relay packs, low-voltage systems, and line-voltage switching all affect compatibility.
                                                                            • PIR works well in spaces with clear line of sight, while dual-technology sensors are often a safer choice in washrooms, classrooms, and irregular rooms where false-off complaints matter.
                                                                            • For retrofit work, matching the installed control family or brand can reduce commissioning time and callback risk.

                                                                            Sensors are the working part of many lighting control systems. They detect occupancy, vacancy, motion, ambient light level, or time-based conditions and trigger switching or dimming responses. For electricians, contractors, and facility teams, the right sensor choice is less about marketing language and more about coverage pattern, mounting method, control logic, load compatibility, and how much setup the site can realistically support. In commercial and institutional projects across Canada, sensor selection often affects energy performance, user complaints, and commissioning time just as much as fixture selection does.

                                                                            What Are Sensors?

                                                                            In this category, sensors are lighting control devices used to detect people or environmental conditions and then signal a lighting system to switch or dim. Common types include occupancy sensors, vacancy sensors, motion sensors, ceiling sensors, wall switch sensors, corner-mount sensors, high-bay sensors, and photocells or daylight sensors. Some are self-contained line-voltage devices that replace a wall switch. Others are low-voltage devices tied into power packs, room controllers, or networked control systems. The main job is simple: turn lights on when needed, turn them off when not needed, or adjust output based on available daylight.

                                                                            Where Are Sensors Used?

                                                                            Sensors are used in offices, classrooms, corridors, washrooms, lunchrooms, storage rooms, utility spaces, warehouses, parking areas, and perimeter zones with daylight exposure. Small enclosed rooms often use wall switch occupancy or vacancy sensors because they are easy to retrofit. Open offices and classrooms commonly use ceiling sensors for broader coverage. Warehouses and gymnasiums may use high-mount sensors designed for higher ceilings and larger motion patterns. Daylight sensors are commonly applied near windows, curtain walls, skylights, and atriums where electric light can be reduced when natural light is available. In multi-space commercial projects, different sensor types are often mixed to suit each room rather than using one device everywhere.

                                                                            How To Choose Sensors

                                                                            Start with the control intent. Decide whether the space needs automatic-on, manual-on, partial-on, auto-off, daylight dimming, or simple scheduled shutoff support. Then match the sensing technology to the room. Passive infrared, or PIR, is usually a good fit where occupants move across the field of view and line of sight is clear. Ultrasonic or dual-technology sensors are often chosen where minor motion detection matters, such as private offices, washrooms, and some classrooms. Next, confirm mounting style, ceiling height, coverage shape, and whether partitions, shelving, doors, or stalls will block detection. Finally, verify electrical details: line voltage or low voltage, switching rating, relay pack requirements, neutral requirement, dimming compatibility, and whether the sensor must integrate with an existing control platform from Watt Stopper, Lutron, Leviton, or Intermatic.

                                                                            Trade Rules Of Thumb

                                                                            As a typical rule of thumb, wall switch sensors are most practical in enclosed rooms where the switch location gives a reasonable view of the occupied area. Ceiling sensors are usually a better choice when the room is larger, furniture layout may change, or the switch location does not provide reliable coverage. PIR sensors generally perform best when occupants move across the detection zones rather than directly toward the sensor. Dual-technology sensors are often worth the extra cost in spaces where false-off complaints are expensive to fix. For daylighting, perimeter zones are commonly controlled separately from interior zones so the whole room does not dim based on window light at one side. Time delay settings are usually chosen to balance energy savings against nuisance shutoff, but they should be treated as application settings rather than fixed rules. These are practical guidelines only and not a substitute for manufacturer instructions, project documents, or applicable Canadian electrical and energy code requirements.

                                                                            Sizing Guidelines

                                                                            Sensor sizing is mostly about coverage and load compatibility rather than conductor ampacity. For coverage, check the stated mounting height and pattern type, such as major motion, minor motion, circular, rectangular, aisleway, or high-bay. A sensor that covers an open 8 ft to 10 ft office ceiling may not perform properly in a 20 ft warehouse or a washroom with partitions. For switching, confirm the connected load type and total load. LED lighting can create compatibility issues if the sensor relay or switch rating is not suited to electronic drivers or inrush current. In low-voltage systems, also confirm the number of sensors, power packs, and controlled zones. For daylight sensors, size by control zone and daylight contribution, not just room size. If the project includes dimming, verify whether the sensor provides on-off control only or supports 0-10V, digital, or system-specific dimming. Final selection should follow the control drawings, manufacturer ratings, and local code requirements.

                                                                            Common Installation Practices

                                                                            Install sensors where they can actually see or detect the occupied area they are meant to control. Avoid placing PIR sensors where doors, tall shelving, partitions, or millwork block the field of view. Keep sensors away from HVAC diffusers, moving air sources, and heat sources when those conditions may affect performance. In washrooms, stalls and partitions often require more careful placement or a different sensing technology than a simple open-room layout. For daylight sensors, avoid aiming them so they read direct sun or fixture output in a way that causes hunting. During retrofit work, label controlled circuits clearly and verify whether the existing box has a neutral if the replacement sensor requires one. After installation, walk-test the coverage, confirm timeout settings, and check operation under normal occupancy conditions rather than relying only on bench assumptions.

                                                                            Common Mistakes

                                                                            One common mistake is choosing a sensor by room size alone without considering partitions, shelving, workstation height, or occupant motion type. Another is assuming any occupancy sensor can switch any LED load. Load type, inrush, and control method still matter. Contractors also run into trouble when they replace a simple switch with a sensor that needs a neutral in a box where no neutral is present. In daylighting applications, poor zoning is a frequent issue; if perimeter and interior fixtures are tied together, the control result is often unsatisfactory. Another avoidable problem is using automatic-on in spaces where users expect manual control or where nuisance activation is likely, such as storage rooms visible from corridors. Finally, many callbacks come from skipped commissioning steps. Even a good sensor can perform badly if timeout, sensitivity, and daylight setpoints are left at unsuitable defaults.

                                                                            Brand Comparisons

                                                                            Watt Stopper is widely specified in commercial lighting control work and is often a strong choice when the project needs a broad sensor range, room control options, and familiar commercial commissioning workflows. Lutron is commonly preferred where sensor control ties into a larger dimming or architectural lighting control system, especially when consistency with an existing Lutron platform matters. Leviton is frequently cross-shopped for practical wallbox devices, room controls, and retrofit-friendly solutions in commercial and light institutional spaces. Intermatic is often considered for straightforward control applications, timing functions, and selected occupancy or photocontrol needs where a simpler approach is suitable. In many jobs, the right brand is the one that matches the installed ecosystem, replacement form factor, and commissioning expectations. If the site already uses one family of sensors and controllers, staying within that family may reduce labour and troubleshooting. If it is a new standalone room or small retrofit, a comparable alternative from another major brand may be perfectly suitable if ratings and control logic align.

                                                                            Related Products

                                                                            Sensor projects are commonly ordered with wall plates, power packs, room controllers, photocells, timers, dimmers, relays, contactors, low-voltage cable, junction boxes, and compatible lighting control accessories. Depending on the application, you may also need ceiling mount adaptors, corner brackets, override switches, emergency bypass components, or network interfaces. For daylight harvesting and dimming projects, confirm compatibility with the fixture driver and any 0-10V or digital control hardware before ordering. On retrofit jobs, it is also worth checking whether replacement face style, colour, and device depth matter for the existing installation.

                                                                            Frequently Asked Questions

                                                                            What is the difference between an occupancy sensor and a vacancy sensor?

                                                                            An occupancy sensor typically turns lights on automatically when it detects presence and turns them off after the timeout period. A vacancy sensor usually requires manual-on operation and then turns lights off automatically when the space is empty. Vacancy control is often chosen where energy savings and nuisance reduction are priorities.

                                                                            When should I use PIR instead of dual-technology sensing?

                                                                            PIR is often suitable for straightforward rooms with clear sight lines and predictable movement. Dual-technology sensing is commonly chosen when the room layout is more difficult, minor motion detection matters, or false-off complaints would be disruptive. Private offices, washrooms, and classrooms are common examples where dual-technology may be worth considering.

                                                                            Do lighting control sensors work with LED fixtures?

                                                                            Many do, but not all combinations are equal. Always verify the sensor's switching or control rating for LED drivers, electronic loads, and any dimming method used. On larger LED circuits, inrush current and control interface details can matter as much as steady-state wattage.

                                                                            Can I replace a regular wall switch with a sensor?

                                                                            Often yes, but check box fill, conductor arrangement, grounding, and whether the new device requires a neutral. Also confirm the connected load type and whether the application calls for occupancy or vacancy logic. Retrofit success depends on both wiring conditions and user expectations.

                                                                            How do I choose a sensor for a washroom or partitioned room?

                                                                            Do not assume an open-room coverage pattern will work once partitions or stalls are present. Review the sensor coverage diagram, mounting height, and technology type carefully. In many partitioned spaces, ceiling placement and dual-technology sensing provide more reliable operation than a basic wall switch sensor.

                                                                            Are daylight sensors only for large commercial buildings?

                                                                            No. They are also useful in smaller perimeter offices, classrooms, lobbies, and retail areas with strong natural light. The key is proper zoning and setup. If the daylight sensor controls fixtures that are not meaningfully affected by window light, the result is usually poor regardless of building size.

                                                                            Sensors

                                                                            :

                                                                            Clear
                                                                            Clear

                                                                            Footer navigation