Important Payment Update: Please remit all payments to Evolt Supply Inc. Payments previously made to Lite-scape Lighting Inc. should now be made to Evolt Supply Inc.
:

Clear
Clear
w0408ml1125-40 siemens, buy siemens w0408ml1125-40 electrical spa packs, siemens electrical spa p...

        Spa Panel Package · 40A 2-Pole GFCI · 4-Space/8-Circuit 125A Main Lug Outdoor NEMA 3R · Siemens W0408ML1125-40

        SKU: W0408ML1125-40
        Outdoor spa panel package with factory-installed 40A 2-pole GFCI breaker in a 125A main lug, 4-space/8-circuit loadcentre. Commonly used for 120/240V single-phase hot tub and spa installations where an outdoor-rated disconnect and GFCI solution is required.
        Siemens Breakers
        386   – Loyalty Rewards
         
        • $386.18
        Available to Order | Typically Arrives in 1 - 3 Weeks Ships From Western Canada Warehouse

        What this product is for

        This Siemens spa panel package is used to supply and protect outdoor hot tubs, spas, and similar equipment requiring a 40A 2-pole GFCI breaker. It combines a 125A main lug loadcentre with a factory-installed GFCI breaker in one outdoor-rated enclosure.

        Use for

        Use for 120/240V AC, single-phase, 3-wire spa and hot tub installations, pool-related equipment where permitted by design, and outdoor branch-circuit distribution needing a NEMA 3R enclosure. The 4-space/8-circuit interior can also provide room for additional accessory circuits where the installation design requires them.

        Avoid for

        Avoid for indoor-only locations, corrosive environments unless additional protection is specified, or applications that require a different breaker size, enclosure type, or service-entrance configuration. Do not assume suitability for every spa pack replacement without confirming voltage, load, breaker type, and local code requirements.

        Best for

        Best for electricians replacing or installing an outdoor spa disconnect with integrated GFCI protection, especially where a compact weather-resistant panel with extra circuit capacity is preferred.

        Installed in

        Typically installed outdoors near residential hot tubs and spas, on exterior walls, service areas, or equipment pads. Enclosure dimensions are approximately 12.25 in H x 6 in W x 4.25 in D (312 x 155 x 108 mm).

        Why this product exists

        This package simplifies spa installations by combining the disconnecting means and required GFCI protection in one assembly. For many hot tub applications, this reduces field assembly time compared with sourcing a separate outdoor loadcentre and breaker.

        Typical buying guidance: a 40A spa panel is commonly selected for hot tubs whose manufacturer calls for a 40A GFCI-protected feeder or branch circuit. Actual suitability depends on the spa nameplate, heater load, pump load, conductor sizing, installation conditions, and local electrical code.

        Compared with similar products

        Compared with a bare outdoor loadcentre, this package includes the factory-matched 40A 2-pole GFCI breaker. Compared with larger spa packs, it is intended for installations that specifically call for 40A protection rather than 50A or 60A. The 125A bus and 4-space/8-circuit layout also provide more flexibility than a simple disconnect-only enclosure.

        Specifications

        • Manufacturer part number: W0408ML1125-40
        • Brand: Siemens
        • Product type: Spa panel package / spa pack
        • Included breaker: 40A, 2-pole GFCI
        • Loadcentre rating: 125A main lug
        • Spaces/Circuits: 4 spaces / 8 circuits
        • Voltage: 120/240V AC
        • Phase: Single-phase
        • Wiring: 3-wire
        • Enclosure type: NEMA 3R outdoor, weather-resistant
        • Construction: Steel enclosure
        • Interrupt rating: 10 kA for included spa panel package listing; base loadcentre references also show 100 kA bus/loadcentre data depending on component context, so verify project submittal requirements before ordering
        • Approximate dimensions: 12.25 x 6 x 4.25 in (312 x 155 x 108 mm)
        • Certification: CSA listed / approved per distributor listings

        Actual performance depends on installation conditions, conductor selection, equipment load, and local electrical code.

          • SKU
            W0408ML1125-40
          • Weight
            2 lbs
        • Brand
          Siemens Breakers
        • Warranty
          5 year
        • Electrical
          • Poles
            2 Pole
          • Amps
            40A
        • Physical
          • Mounting
            Bolt On
          • Breaker Type
            Ground Fault

        Minimum Order $20

        We accept the following payment methods:

        Accepted payment methods

        Credit Card can offer cardholders convenience, security, rewards, and the opportunity to build a healthy credit history.

        Click here for Contractor Cash Account


        Trade Credit is a standard financing option for contractors and construction companies to obtain supplies and keep their projects moving. We offer 30-day credit terms to trade contractors on approved applications only. 

        Click here for Contractor Credit Account 


        Standard Shipping-Free on orders over $500 in Metropolitan Areas / Subject to $750 in Rural Areas.


        Minimum Order Is $20

        Freight Surcharge Apply To Oversized/Over-Weight Items(Not Limited To):
         

        • PVC and EMT Pipe 
        • Wire and Cable 
        • Items over 48 inches in length 

        Surcharges are applied to items on an individual basis regardless if the rest of the order meets prepaid levels. If a freight line appears at the time of check out it only applies to the Items carrying a surcharge and not the entire basket of goods.

        Shipping Options:

        • A courier can deliver to your home, office, or your job site
        • Pick up at local depot near you (applies to the following locations)

        Edmonton Warehouse 8135 Roper Rd Edmonton, T6E 6S4, AB 

        Orders are typically delivered within two to eleven business days. The transit time begins the first full shipping day after your order leaves our warehouse. Please allow an additional 2-5 days for delivery to remote locations, additional fees may apply.

        THE FOLLOWING APPLIES TO STANDARD SHIPPING OPTIONS

        • We cannot deliver to P.O. boxes.
        • A signature may be required for shipments over $500.
        • No weekend delivery.
        • Wire & cable, EMT or PVC conduit, tube lamps 4ft or greater, and 10ft ground rods & mast pipes have special conditions.

        Standard Shipping cost on orders less than $499

        Total shipping cost = "Per Shipment" cost + "Per Item" cost.  The "per item" cost is listed in terms of price per pound.

         

        Product Group

        Per Shipment*

        Per Item

        Boxes

        $6.99

        $1.49/lb

        Conduit & Raceway

        $149.99

        $2.49/lb

        Connectors & Fittings

        $5.99

        $1.19/lb

        Data & Structured Home

        $5.99

        $1.19/lb

        Distribution Equipment

        $5.99

        $1.19/lb

        Emergency Lighting

        $6.99

        $1.49/lb

        Heating & Ventilation

        $6.99

        $1.49/lb

        Lighting Controls

        $5.99

        $1.19/lb

        Lighting Indoor

        $6.99

        $1.49/lb

        Lighting Outdoor

        $6.99

        $1.49/lb

        Tools

        $4.99

        $.99/lb

        Wire & Cable

        $49.99

        $2.29/lb

        Wiring Devices

        $5.99

        $1.19/lb

        Any combination of the above items

        Highest applicable per-shipment charge

        As above

        Effective Date: August, 15, 1998(Updated August 2026)

        At Evolt Electrical Supply, customer satisfaction is our top priority. Please review our return policy below:

        Returns

        Defective Items:

        • If you receive a defective item, you may return it for a replacement or refund within 30 days of purchase.
        • To initiate a return, please contact our customer service team with your order number and a description of the defect.

        Non-Defective Items:

        • We do not accept returns for non-defective items. All sales are final once the product is shipped or ordered from the manufacturer. In certain circumstances we may amend this so feel free to contact our customer service team.

        Return Process

        Authorization:

        • Before returning any items, you must obtain a Return Merchandise Authorization (RMA) number from our customer service team. Returns without an RMA number will not be accepted.
        • Backordered items can not be cancelled if the item is in transit from the manufacturer, contact us to review.

        Shipping:

        • Customers are responsible for the return shipping costs. We recommend using a trackable shipping service or purchasing shipping insurance.

        Condition:

        • Returned items must be in their original packaging and condition. Any items returned damaged due to improper packaging or misuse will not be eligible for a refund or replacement.

        Refunds

        • Once we receive and inspect your returned item, we will notify you of the approval or rejection of your refund.
        • Approved refunds will be processed within [7] business days and a credit will automatically be applied to your original method of payment.

        Related products

        Footer navigation