Conduit Hanger · 2 in Trade Size · For EMT/IMC/Rigid Support · Global UH200
UH200
1 – Loyalty RewardsP-Clamp · 1/2 in EMT/Rigid Trade Size · 1-Piece Adjustable Saddle Clamp for Strut · Allyco Supply SSC-05
SSC-05
Available to Order | Typically Arrives in 1 - 3 Weeks3 – Loyalty RewardsP-Clamp · 3/4 in EMT/Rigid Trade Size · For Strut Mounting · Allyco Supply SSC-07
SSC-07
Available to Order | Typically Arrives in 1 - 3 Weeks3 – Loyalty RewardsP-Clamp · 1 in EMT/Strut Size · For Conduit Support on Strut · Allyco Supply SSC-10
SSC-10
Available to Order | Typically Arrives in 1 - 3 Weeks3 – Loyalty RewardsP-Clamp · 1-1/4 in EMT Size · For Strut and EMT Support · Allyco Supply SSC-12
SSC-12
Available to Order | Typically Arrives in 1 - 3 Weeks3 – Loyalty RewardsP-Clamp · 1-1/2 in EMT/Strut Size · One-Piece Saddle Style · Allyco Supply SSC-15
SSC-15
Available to Order | Typically Arrives in 1 - 3 Weeks4 – Loyalty RewardsStrut Clamp · 2 in EMT · Steel Electrogalvanized · Allyco Supply SSC-20
SSC-20
Available to Order | Typically Arrives in 1 - 3 Weeks5 – Loyalty Rewards
Quick Decision Summary
- Choose conduit clamps by conduit trade size, mounting surface, indoor or outdoor exposure, and whether you need a one-hole or two-hole style.
- For straight EMT runs on walls and structure, installers often choose simple support straps or clamps that match the conduit size exactly.
- Two-fastener styles generally give better alignment and holding strength on longer runs or where vibration is a concern.
- Material and finish matter. Dry indoor work may use standard steel, while damp, corrosive, or washdown areas may need better corrosion resistance.
- Always confirm support spacing, securement, and installation method to the applicable Canadian Electrical Code, local authority requirements, and site conditions.
Conduit clamps are small parts, but they affect how cleanly an EMT installation goes in, how well the raceway stays aligned, and how much rework shows up at inspection. For electricians, maintenance teams, and contractors, the right clamp choice comes down to fit, fastening method, finish, and the realities of the mounting surface. On EMT jobs, a clamp that installs quickly but still holds the run straight can save time across an entire floor, mechanical room, or retrofit package.
What Are Conduit Clamps?
Conduit clamps are support and fastening components used to secure EMT to walls, ceilings, strut, framing, masonry, or equipment structure. In trade use, the term can include one-hole straps, two-hole straps, snap-on supports, and other clamp styles intended to hold conduit in position without crushing or distorting the raceway. For EMT, the clamp must match the conduit trade size and should allow a firm hold while keeping the tubing round and properly aligned for couplings, connectors, and box entries.
Where Are Conduit Clamps Used?
Conduit clamps are used anywhere EMT needs to be supported and secured as part of a complete raceway installation. Common applications include commercial tenant fit-outs, retail spaces, schools, warehouses, service rooms, plant maintenance work, and light industrial areas. They are also common in retrofit work where conduit is being added to block, concrete, steel, or finished surfaces. In exposed work, clamp selection affects not only support but also appearance, because uneven clamp spacing or the wrong style can make an otherwise good conduit run look rough.
How To Choose Conduit Clamps
Start with conduit type and trade size. EMT clamps are sized to the raceway, and a poor fit can lead to movement, deformation, or a run that does not sit flat. Next, look at the mounting surface. Wood, steel, concrete, and masonry all change the fastener choice and sometimes the clamp style. Then consider environment. Dry indoor spaces may allow standard plated steel, while damp or corrosive areas may call for a more protective finish or a different support approach. Also think about labour. A one-hole style can be quick for short runs and touch-up work, while a two-hole style often helps keep longer runs straighter. If the area has vibration, repeated access, or mechanical activity, choose a support method that resists loosening and keeps the conduit stable over time.
Trade Rules Of Thumb
As a practical rule of thumb, conduit clamps should fit the EMT snugly without forcing the tubing out of round. For exposed work where appearance matters, many electricians keep clamp spacing visually consistent even when code allows wider intervals. Two-fastener supports are often preferred on larger EMT sizes, longer straight runs, or where the conduit may be bumped. On retrofit jobs, it is usually worth checking the actual outside condition of the wall or structure before choosing fasteners, because uneven block, old concrete, or thin sheet metal can change what clamp and anchor combination works best. These are installation practices, not code substitutes, and final support spacing and securement must follow the applicable code and local inspection requirements.
Sizing Guidelines
Conduit clamps are normally selected by the same trade size as the EMT being installed, such as 1/2 in, 3/4 in, 1 in, and larger. Do not assume all clamp profiles are interchangeable across brands or styles. A clamp that is technically the right nominal size may still sit differently depending on shape, material thickness, and intended use. For buying and planning, match the clamp to the conduit trade size first, then confirm the mounting hole pattern, fastener size, and clearance around couplings, bends, and box offsets. On larger conduit or where multiple parallel runs are being installed, check that the clamp width and screw placement leave enough room for tools and proper alignment. If the installation is engineered or subject to project-specific support details, follow the drawings and approved submittals.
Common Installation Practices
Installers typically lay out box locations, bends, and couplings first, then place conduit clamps so the run stays straight and supported without fighting the natural line of the tubing. On masonry or concrete, pre-planning anchor locations helps avoid drilling conflicts and uneven spacing. On steel or strut, keeping clamp centres consistent improves both appearance and serviceability. It is also common practice to avoid over-tightening clamps, especially on EMT, because excessive force can flatten the raceway and create problems at connectors or couplings. In damp or washdown-adjacent spaces, crews often pay closer attention to finish compatibility, fastener corrosion resistance, and whether the support method will trap moisture or debris.
Common Mistakes
One common mistake is treating all conduit clamps as generic hardware. A clamp that is close enough in size can still fit poorly and lead to movement or a crooked run. Another is choosing the clamp without considering the mounting surface, then losing time on site because the fastener or anchor method does not suit the substrate. Over-tightening is also common and can damage EMT. In exposed work, inconsistent clamp spacing and mixed clamp styles can make the installation look patched together. Buyers also sometimes focus only on unit price and overlook labour impact. A clamp that installs faster, aligns better, or reduces call-backs may be the better value on commercial and maintenance work.
Brand Comparisons
Bridgeport is a well-known choice for fittings and support hardware and is commonly selected when contractors want dependable fit and familiar installation across standard EMT work. In the broader market, Wheatland and Atkore are strongly associated with raceway systems, while T&B is widely recognized across fittings, connectors, and support products. In practice, many buyers match the installed system, project spec, or contractor preference rather than chasing a single brand across every job. Bridgeport is a sensible option for many standard EMT clamp applications, especially when consistency with other Bridgeport fittings matters. If a project already standardizes on another approved brand, matching that system may still be the right call for submittal acceptance, appearance, or maintenance consistency.
Related Products
Conduit clamps are usually purchased alongside EMT connectors, couplings, straps, locknuts, bushings, strut channel, strut straps, beam clamps, anchors, screws, and boxes. On retrofit and exposed work, fastener selection is often just as important as the clamp itself. Buyers may also need masonry anchors, self-drilling screws, channel nuts, or support accessories depending on whether the conduit is being mounted to concrete, steel, wood, or existing framing. For complete raceway planning, it also helps to review conduit bodies, box offsets, and support hardware so the full run can be installed cleanly and serviced later.
Frequently Asked Questions
Are conduit clamps and conduit straps the same thing?
In everyday trade language, they are often used interchangeably. The exact product style can differ, but both terms usually refer to hardware used to secure conduit to a surface or support structure.
Do I need to match the clamp size exactly to the EMT size?
Yes. As a normal buying and installation practice, the clamp should match the EMT trade size. Using a near match can lead to poor support, movement, or conduit deformation.
When should I use a two-hole clamp instead of a one-hole style?
Two-hole styles are often preferred where better alignment, stronger hold, or improved stability is needed, such as on longer runs, larger conduit, or areas with vibration or frequent contact.
Can standard steel conduit clamps be used outdoors?
Not always. Outdoor or damp-location use depends on the clamp material, finish, fasteners, and the overall installation environment. Check the product suitability and project requirements before ordering.
Do conduit clamps determine code compliance by themselves?
No. The clamp is only one part of the support system. Compliance depends on the complete installation, including clamp type, spacing, fastening method, raceway type, and the applicable Canadian Electrical Code and local authority requirements.
Is Bridgeport a good choice for EMT conduit clamps?
Bridgeport is commonly chosen for EMT fittings and support hardware and is a practical option for many standard commercial and maintenance applications. Final selection should still be based on fit, finish, project spec, and site conditions.