          Low Voltage Thermostat Wire · 18 AWG 2 Conductor · Brown 75 m Cut-to-Length · Various Mfg. LVT2C18-75
          LVT2C18-75
          1   – Loyalty Rewards
          • $1.17
          Available to Order | Typically Arrives in 1 - 3 Weeks Ships From Western Canada Warehouse
          Click the image to back order this item from the product page

        Quick Decision Summary

        • LVT wire is generally used for low-voltage control, signal, annunciation, and similar light-duty circuit wiring rather than branch circuit power distribution.
        • Choose by voltage rating, conductor size, stranding, insulation type, temperature rating, and whether the wire will be installed in panels, raceways, or equipment assemblies.
        • For control work, stranded conductors are often easier to terminate and route than solid conductors, especially in tighter enclosures.
        • Confirm compatibility with the equipment, terminal type, and installation method before ordering, especially where multiple conductors share a raceway or enclosure.
        • Wire selection and installation must follow the Canadian Electrical Code, local inspection requirements, and the equipment manufacturer's instructions.

        LVT wire is commonly specified for low-voltage control and signal applications where electricians, panel builders, maintenance teams, and OEM buyers need compact conductors for reliable terminations and orderly routing. In practice, buyers usually care less about the label alone and more about whether the wire suits the control voltage, enclosure conditions, flexibility needs, and termination method. When you are comparing options, the practical questions are conductor size, stranded versus solid construction, insulation toughness, temperature rating, and whether the wire is intended for internal equipment wiring, control panels, or raceway-based field wiring.

        What Are LVT Wire?

        LVT wire generally refers to low-voltage thermoplastic insulated wire used for control, signal, annunciation, and similar circuits where the electrical load is modest and the wiring needs are more about dependable signalling than carrying significant power. Depending on the exact product, it may be used in control cabinets, relay logic, instrumentation-related circuits, HVAC controls, security interfaces, or other low-energy wiring tasks. Because naming conventions can vary by manufacturer and market segment, buyers should verify the actual listing, insulation type, conductor material, and intended application instead of relying on the abbreviation alone.

        Where Are LVT Wire Used?

        LVT wire is typically used in control panels, machine wiring, building control systems, alarm and signal circuits, and other low-voltage applications where compact wiring and clear identification matter. It may also be used in equipment interconnections, terminal strip wiring, contactor and relay control circuits, and low-current switching loops. In commercial and industrial settings, it is often selected where installers need neat panel layout, manageable bend radius, and straightforward termination on small control devices. It is generally not the first choice for standard building branch circuit wiring, feeder work, or applications requiring a cable assembly such as armoured cable or NMD90.

        How To Choose LVT Wire

        Start with the actual circuit function. If the wire is for dry-contact control, signalling, PLC I/O, relay logic, or similar low-current work, focus on conductor size, flexibility, and insulation suitability. Check the required voltage rating and temperature rating against the equipment and environment. For panel work, stranded wire is often preferred because it routes more cleanly and reduces stress at terminals during servicing. For repetitive machine motion or vibration, finer stranding may be more suitable than basic building-style conductors. Also confirm whether colour coding matters for troubleshooting, whether ferrules will be used, and whether the wire must fit crowded wireways, ducts, or small terminal blocks. If the installation leaves the enclosure and enters a raceway or field wiring path, verify that the selected wire type is acceptable for that use and not limited to internal equipment wiring only.

        Trade Rules Of Thumb

        For many control applications, smaller conductors are chosen to save panel space, but the wire still needs enough mechanical strength for stripping, termination, and future maintenance. As a rule of thumb, stranded conductors are usually easier to work with in control cabinets and on devices with compact terminals. Another practical rule is to leave room for identification and service loops rather than packing wireways completely full. Where low-voltage circuits run near power conductors, separation and routing discipline help reduce noise and troubleshooting issues. These are practical trade habits, not code substitutes, and final selection should always match the equipment documentation and applicable Canadian requirements.

        Sizing Guidelines

        LVT wire sizing is usually driven by three things: current, voltage drop, and terminal compatibility. In short control runs inside a panel, current and terminal size often matter more than voltage drop. In longer low-voltage runs, especially where control voltage is modest, voltage drop can become a real issue even at low current. As a typical buying approach, choose a conductor size that the terminal is designed to accept, then confirm the circuit current and run length are still appropriate. If multiple conductors are grouped in a warm enclosure, temperature and bundling effects may also influence selection. Exact conductor sizing, ampacity, and installation allowances must be verified against the Canadian Electrical Code, product approvals, and the equipment manufacturer's instructions.

        Common Installation Practices

        Good installation practice for LVT wire includes consistent colour coding, clear wire marking, proper stripping length, and secure routing in wire duct or along defined panel paths. Many electricians and panel builders use ferrules on fine-stranded conductors where terminal design and manufacturer instructions support them, because this can improve termination consistency. Keep low-voltage control wiring organized away from higher-noise power wiring where practical, and avoid sharp bends or excessive tie-wrap tension that can damage insulation over time. Before energizing, verify terminal torque, conductor identification, and continuity. If the wire exits equipment or enters a raceway system, confirm the installation method is permitted for that specific wire type and listing.

        Common Mistakes

        One common mistake is assuming all low-voltage wire is interchangeable. In reality, control wire, communication cable, thermostat cable, and internal appliance or equipment wire can have very different approvals and permitted uses. Another mistake is choosing the smallest possible conductor without considering voltage drop, terminal grip, or future servicing. Installers also run into problems when they mix solid and stranded conductors on terminals not suited to both, or when they use wire with insulation that is too stiff for compact panel work. A further issue is using a wire type outside its intended environment, such as exposing an internal wiring product to field conditions, moisture, abrasion, or unsupported runs it was not designed for.

        Brand Comparisons

        Brand selection in LVT wire is often less about name recognition alone and more about availability, listing clarity, conductor consistency, insulation quality, and whether the product line matches the job. Some buyers prefer to match an existing installed brand in OEM panels or facility standards to simplify maintenance and documentation. Others will cross-shop based on lead time, colour availability, spool length, and whether the insulation strips cleanly without nicking strands. Where no specific brand standard exists, a comparable approved alternative may be suitable for many standard control applications, provided the ratings and intended use match the job requirements. For replacement work, matching the existing wire style and identification scheme is often more important than changing brands.

        Related Products

        Products commonly purchased alongside LVT wire include wire ferrules, ring and fork terminals, butt splices, terminal blocks, wire markers, cable ties, wire duct, control transformers, relays, contactors, panel accessories, and test instruments. Depending on the application, buyers may also need flexible conduit, raceway fittings, control enclosures, DIN rail components, and low-voltage overcurrent protection. If the project involves field-installed control circuits rather than only internal panel wiring, review whether a different cable or conductor type is more appropriate for the run conditions and installation method.

        Frequently Asked Questions

        Is LVT wire the same as building wire?

        No. LVT wire is generally associated with low-voltage control or signal applications, while building wire types such as NMD90, RW90, or other power wiring products are selected for different installation methods and circuit duties. Always confirm the exact wire type and approval before substituting.

        Can LVT wire be used for 120V or 347V branch circuits?

        It should not be assumed suitable. The answer depends on the specific product rating, approval, and intended use. Many low-voltage control wires are not meant to replace standard branch circuit wiring methods. Check the product markings and applicable code rules before use.

        Should I choose stranded or solid LVT wire?

        For most control panel and equipment wiring, stranded wire is often preferred because it is easier to route and terminate in tight spaces. Solid conductors may be acceptable in some applications, but they are generally less forgiving during servicing and repeated movement.

        What matters most when selecting conductor size for LVT wire?

        The main factors are circuit current, voltage drop, terminal compatibility, and mechanical practicality. In short panel runs, terminal fit and handling may drive the choice. In longer low-voltage runs, voltage drop can become the limiting factor.

        Can I run LVT wire in the same pathway as power conductors?

        That depends on the wire type, circuit classification, equipment design, and applicable code rules. Even where permitted, many installers separate sensitive control wiring from power conductors where practical to reduce electrical noise and simplify troubleshooting.

        Is colour coding important for LVT wire?

        Yes. Consistent colour coding helps commissioning, maintenance, and fault finding. Many shops and facilities follow internal standards for DC control, AC control, commons, interlocks, and safety-related circuits, but those conventions should be documented and applied consistently.