- Stock in Calgary
- 535 In Calgary Warehouse As Of June 5th, 202613 – Loyalty Rewards
- Stock in Calgary
1150 Lumens 12 Watts T8 3FT Ballast Bypass Fluorescent To LED Retrofit Lamp 30/35/40/50/65K Eiko Lighting L12WT8/36/BSDG/FCCT
L12WT8/36/BSDG/FCCT
679 In Calgary Warehouse As Of June 5th, 202613 – Loyalty Rewards- Stock in Calgary
1450 Lumens 12 Watts T8 3FT Ballast Bypass Fluorescent To LED Retrofit Lamp 40K Eiko Lighting L12WT8/36/BSDG/840
L12WT8/36/BSDG/840
526 In Calgary Warehouse As Of June 5th, 202612 – Loyalty Rewards- Stock in Calgary
1650 Lumens 9.5 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 35K Eiko Lighting L9.5WT8/48/BSDG/835
L9.5WT8/48/BSDG/835
525 In Calgary Warehouse As Of June 5th, 202610 – Loyalty Rewards- Stock in Calgary
1650 Lumens 9.5 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 40K Eiko Lighting L9.5WT8/48/BSDG/840
L9.5WT8/48/BSDG/840
216 In Calgary Warehouse As Of June 5th, 202610 – Loyalty Rewards- Edmonton Stock: 1
- 3% off trade
1800 Lumens 18 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 4K NaturaLED LED15T8/FR18/840G1
LED15T8/FR18/840G1
Out of stock6 – Loyalty Rewards- Stock in Calgary
1800 Lumens 12 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 40K Eiko Lighting L12WT8/48/BSDG/840
L12WT8/48/BSDG/840
1920 In Calgary Warehouse As Of June 5th, 20268 – Loyalty Rewards- Stock in Calgary
1800 lm T8 LED Tube · 12W 4 ft 3500K · Ballast Bypass Single/Double-Ended Glass · Eiko L12WT8/48/BSDG/835
L12WT8/48/BSDG/835
166 In Calgary Warehouse As Of June 5th, 202610 – Loyalty Rewards- Stock in Calgary
1800 Lumens 15 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 50K Eiko Lighting L15WT8/48/BSG/850
L15WT8/48/BSG/850
345 In Calgary Warehouse As Of June 5th, 202610 – Loyalty Rewards- Stock in Calgary
1800 Lumens 12 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 50K Eiko Lighting L12WT8/48/BSDG/850
L12WT8/48/BSDG/850
4541 In Calgary Warehouse As Of June 5th, 20268 – Loyalty Rewards- Stock in Calgary
1800 Lumens 14 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 30/35/40/50/65K Eiko Lighting L14WT8/48/BSDG/FCCT
L14WT8/48/BSDG/FCCT
7325 In Calgary Warehouse As Of June 5th, 20269 – Loyalty Rewards- Stock in Calgary
1800 Lumens 15 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 40K Eiko Lighting L15WT8/48/BSG/840
L15WT8/48/BSG/840
2604 In Calgary Warehouse As Of June 5th, 202610 – Loyalty Rewards- Stock in Calgary
1900 Lumens 14.5 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 40K Eiko Lighting LED14.5WT8/48/840-DT-PET-G9D
LED14.5WT8/48/840-DT-PET-G9D
185 In Calgary Warehouse As Of June 5th, 202617 – Loyalty Rewards- Stock in Calgary
2100 Lumens 14.5 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 30/35/40/50/65K Eiko Lighting L14.5WT8-48-BDP-840
L14.5WT8-48-BDP-840
500 In Calgary Warehouse As Of June 5th, 202610 – Loyalty Rewards- Stock in Calgary
2100 Lumens 14.5 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 30/35/40/50/65K Eiko Lighting L14.5WT8-48-BDP-850
L14.5WT8-48-BDP-850
50 In Calgary Warehouse As Of June 5th, 202610 – Loyalty Rewards2200 Lumens 15 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 5K Votatec SYHU-T8GABBEUL1215PM-50
SYHU-T8GABBEUL1215PM-50
Available to Order | Typically Arrives in 1 - 3 Weeks Ships From Ontario Importer Warehouse37 – Loyalty Rewards- Stock in Calgary
2200 Lumens 15 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 50K Eiko Lighting L15WT8/48/BSDG/850
L15WT8/48/BSDG/850
3258 In Calgary Warehouse As Of June 5th, 20269 – Loyalty Rewards- Stock in Calgary
2200 Lumens 15 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 40K Eiko Lighting L15WT8/48/BSDG/840
L15WT8/48/BSDG/840
5500 In Calgary Warehouse As Of June 5th, 20269 – Loyalty Rewards- Stock in Calgary
2200 Lumens 15 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 35K Eiko Lighting L15WT8/48/BSDG/835
L15WT8/48/BSDG/835
479 In Calgary Warehouse As Of June 5th, 20269 – Loyalty Rewards- Stock in Calgary
2600 Lumens 18.5 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 40K Eiko Lighting LED18.5WT8/48/840-G8D
LED18.5WT8/48/840-G8D
167 In Calgary Warehouse As Of June 5th, 202621 – Loyalty Rewards- Stock in Calgary
2600 Lumens 18.5 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 50K Eiko Lighting LED18.5WT8/48/850-G8D
LED18.5WT8/48/850-G8D
375 In Calgary Warehouse As Of June 5th, 202621 – Loyalty Rewards- Stock in Calgary
2850 Lumens 20 Watts T8 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 50K Eiko Lighting LED20WT8/48/850-NPC-G9D
LED20WT8/48/850-NPC-G9D
767 In Calgary Warehouse As Of June 5th, 20269 – Loyalty Rewards- Stock in Calgary
3500 Lumens 24 Watts T8 8FT Ballast Bypass Fluorescent To LED Retrofit Lamp 50K Eiko Lighting LED24WT8/96/850-FA8-G9D
LED24WT8/96/850-FA8-G9D
32 In Calgary Warehouse As Of June 5th, 202640 – Loyalty Rewards4200 Lumens 30 Watts T8 6FT Ballast Bypass Fluorescent To LED Retrofit Lamp 65K Eiko Lighting LED30WT8/72/865-DS-G8
LED30WT8/72/865-DS-G8
Contact Us For Delivery ETA39 – Loyalty Rewards- Edmonton Stock: 40
- 2% off trade
- Edmonton Stock: 2
- Stock in Calgary
5500 lm T8 LED Tube · 40W · 8 ft Ballast Bypass Double-Ended R17D 4000K · EiKO LED40WT8/96/840-R17D-G9D
LED40WT8/96/840-R17D-G9D
7 In Calgary Warehouse As Of June 5th, 202640 – Loyalty Rewards5500 Lumens 40 Watts T8 8FT Ballast Bypass Fluorescent To LED Retrofit Lamp 50K Eiko Lighting LED40WT8/96/850-FA8-G9D
LED40WT8/96/850-FA8-G9D
Contact Us For Delivery ETA40 – Loyalty Rewards- Stock in Calgary
5800 lm LED T8 Sign Tube · 42W 9 ft · Double-Sided Ballast Bypass, 6500K, R17d · EiKO LED42WT8/108/865-DS-G8
LED42WT8/108/865-DS-G8
40 In Calgary Warehouse As Of June 5th, 202636 – Loyalty Rewards- Stock in Calgary
1000 Lumens 7 Watts T5 2FT Ballast Bypass Fluorescent To LED Retrofit Lamp 4K Eiko Lighting LED7WT5HE/22/840-G9D
LED7WT5HE/22/840-G9D
60 In Calgary Warehouse As Of June 5th, 202614 – Loyalty Rewards- Stock in Calgary
1740 lm T5 LED Retrofit Tube · 12W 4000K 3 ft Ballast Bypass · G5 Base · EiKO LED12WT5HE/34/840-G9D
LED12WT5HE/34/840-G9D
25 In Calgary Warehouse As Of June 5th, 202617 – Loyalty Rewards- Stock in Calgary
1800 Lumens 15 Watts T5 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 35K Eiko Lighting LED15WT5HE/46/835-G9D
LED15WT5HE/46/835-G9D
500 In Calgary Warehouse As Of June 5th, 202615 – Loyalty Rewards- Stock in Calgary
1900 Lumens 15 Watts T5 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 50K Eiko Lighting LED15WT5HE/46/850-G9D
LED15WT5HE/46/850-G9D
150 In Calgary Warehouse As Of June 5th, 202615 – Loyalty Rewards- Stock in Calgary
1900 lm T5 LED retrofit tube · 15W 4 ft 4000K 120-277V ballast bypass · glass double-ended Type B · Eiko Lighting LED15WT5HE/46/840-G9D
LED15WT5HE/46/840-G9D
230 In Calgary Warehouse As Of June 5th, 202615 – Loyalty Rewards3200 Lumens T5 LED Retrofit Tube · 24W 4 ft 4000K · Type A+B ballast compatible/bypass · Votatec PVT5-4FT-24WAB-40K
PVT5-4FT-24WAB-40K
Available to Order | Typically Arrives in 1 - 3 Weeks Ships From Ontario Importer Warehouse45 – Loyalty Rewards3200 Lumens 24 Watts T5 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 5K Votatec PVT5-4FT-24WAB-50K
PVT5-4FT-24WAB-50K
Available to Order | Typically Arrives in 1 - 3 Weeks Ships From Ontario Importer Warehouse45 – Loyalty Rewards- Stock in Calgary
3300 Lumens 24 Watts T5 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 35K Eiko Lighting LED24WT5HO/46/835-G9D
LED24WT5HO/46/835-G9D
75 In Calgary Warehouse As Of June 5th, 202617 – Loyalty Rewards- Stock in Calgary
3375 Lumens 25 Watts T5 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 40K Eiko Lighting LED25WT5HO/46/840-G8D-347V
LED25WT5HO/46/840-G8D-347V
189 In Calgary Warehouse As Of June 5th, 202618 – Loyalty Rewards3500 Lumens 24 Watts T5 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 40K Eiko Lighting LED24WT5HO/46/840-G9D
LED24WT5HO/46/840-G9D
Contact Us For Delivery ETA17 – Loyalty Rewards- Stock in Calgary
3500 Lumens 24 Watts T5 4FT Ballast Bypass Fluorescent To LED Retrofit Lamp 50K Eiko Lighting LED24WT5HO/46/850-G9D
LED24WT5HO/46/850-G9D
45 In Calgary Warehouse As Of June 5th, 202617 – Loyalty Rewards
Quick Decision Summary
- LED tube ballast bypass lamps are direct-wire replacement lamps that run on line voltage after the fluorescent ballast is removed or disconnected.
- They are commonly chosen to eliminate ballast failures, reduce maintenance calls, and simplify future lamp replacement in older fluorescent fixtures.
- Before ordering, confirm tube length, lamp type, input voltage, single-end or double-end wiring, base style, and whether existing lampholders are shunted or non-shunted.
- Ballast bypass retrofits change fixture wiring, so installation should be done by qualified personnel and verified against the applicable Canadian Electrical Code requirements and local authority interpretation.
LED tube ballast bypass lamps are a practical retrofit choice for commercial, institutional, light industrial, and property maintenance work where fluorescent T8 or T12 fixtures are still in service but ballast reliability has become a problem. For electricians and facility teams, the main buying decision is not just lamp wattage or colour temperature. The real issues are wiring method, lampholder compatibility, fixture condition, voltage, and whether the site wants the lowest first cost or the simplest long-term maintenance approach. In many retrofit programs, direct-wire tubes make sense when the fixture body is still usable and the goal is to keep labour predictable while removing the ballast as a future failure point.
What Are LED Tube Ballast Bypass?
LED tube ballast bypass lamps are linear LED replacement lamps designed to operate without a fluorescent ballast. They are often called direct-wire LED tubes or line-voltage LED tubes. Instead of feeding the lamp through the existing ballast, the installer rewires the fixture so the lamp receives the required supply directly. Depending on lamp design, power may be fed to one end of the lamp only or split across both ends. This matters because the correct lampholder type and wiring layout must match the lamp instructions. These products are commonly used to replace fluorescent T8 and some T12 systems where the fixture housing and reflector are still serviceable but the owner wants lower maintenance and improved energy use.
Where Are LED Tube Ballast Bypass Used?
These lamps are widely used in offices, schools, retail back rooms, warehouses, utility corridors, apartment common areas, parking support spaces, workshops, and maintenance facilities. They are especially useful in buildings with a large installed base of older strip fixtures, wrap fixtures, and troffers where ballast failures are frequent. They are also common in staged retrofit work where a full fixture replacement is not yet in budget. For property managers and maintenance departments, ballast bypass tubes can reduce repeat service calls caused by aging fluorescent gear. For contractors, they are often a practical option when the fixture is mechanically sound, lensing is acceptable, and the customer wants a straightforward lamp-and-rewire retrofit rather than a full luminaire changeout.
How To Choose LED Tube Ballast Bypass
Start with the fixture and existing lamp format. Confirm whether you are replacing 4 ft T8, 8 ft, T12, U-bend, or another linear format. Next, verify the lamp wiring style. Single-end power lamps usually require non-shunted lampholders and careful polarity placement at one end. Double-end power lamps are often simpler for retrofit crews because line and neutral are landed on opposite ends, but the exact method still depends on the lamp instructions. Check supply voltage, especially in commercial buildings where 120V and 347V may both exist. Then choose light output and colour temperature based on the space. A maintenance corridor may accept lower output and cooler colour, while offices, classrooms, and tenant areas often need more controlled light levels and a more neutral appearance. Also consider frosted versus clear lens style, DLC or rebate relevance where applicable, and whether the customer wants to standardise on one lamp family across multiple buildings.
Trade Rules Of Thumb
As a typical rule of thumb, ballast bypass tubes are most attractive when the fixture body is still worth keeping but the ballast is near end of life or already failing. In maintenance-heavy sites, removing the ballast often reduces nuisance failures and simplifies troubleshooting because future lamp issues are no longer mixed with ballast issues. For buying decisions, double-end powered lamps are often preferred where crews want familiar fixture rewiring and broad compatibility, while single-end powered lamps may be chosen when the lamp design or project standard calls for it. Another practical rule is to inspect lampholders before quoting. Brittle tombstones, heat damage, cracked sockets, and poor grounding can turn a simple lamp retrofit into a fixture repair. Light level matching should be treated as approximate. Do not assume every fluorescent lamp can be replaced one-for-one by wattage alone. Compare lumen output, beam distribution, lens condition, and room reflectance.
Sizing Guidelines
For linear LED retrofits, sizing usually means matching lamp length, base type, voltage, and light output to the existing application rather than doing conductor sizing. As an approximate lighting rule, storage and utility areas may need modest light levels, while offices, classrooms, and task-oriented spaces usually need higher delivered lumens. When replacing older fluorescent systems, many buyers compare the existing lamp count and nominal fluorescent type first, then select an LED tube with similar or slightly improved delivered light. If the fixture has yellowed lenses, dirty reflectors, or poor optics, a higher-output lamp may be needed to maintain acceptable results. For multi-lamp troffers, also consider whether all lamps need replacement or whether a lower lamp count retrofit is acceptable. Any fixture rewiring, branch circuit work, or voltage verification should be completed by qualified personnel, and final suitability should be confirmed for the specific fixture and installation conditions.
Common Installation Practices
Typical ballast bypass practice starts with isolating power, opening the fixture, identifying supply voltage, and removing or permanently disconnecting the ballast in accordance with the lamp instructions and site standards. Installers then verify lampholder type, replace damaged tombstones as needed, and rewire the fixture for the selected single-end or double-end lamp configuration. Many contractors label the fixture internally to show that it has been converted from fluorescent ballast operation to direct-wire LED operation. It is also common to replace questionable lampholders during the same visit rather than risk a callback. In larger retrofit programs, crews often standardise one wiring method, one colour temperature, and one approved lamp family to reduce confusion during future maintenance. Because this is a fixture modification, product instructions, local inspection requirements, and applicable Canadian code interpretation should always be followed.
Common Mistakes
One of the most common mistakes is ordering lamps before confirming whether the fixture uses shunted or non-shunted lampholders. Another is assuming all direct-wire tubes wire the same way. They do not. Mixing single-end and double-end assumptions can create unsafe or non-working installations. Buyers also sometimes overlook voltage range, especially in mixed-voltage commercial properties. Another frequent issue is trying to save labour by leaving damaged tombstones in place, which often leads to intermittent lamp operation later. On the lighting side, replacing fluorescent lamps by wattage only can produce disappointing results if lumen output, lens losses, and room use are not considered. Finally, some retrofits should not be lamp-only projects at all. If the fixture is rusted, poorly grounded, mechanically damaged, or optically inefficient, a full fixture replacement may be the better long-term decision.
Brand Comparisons
Osram, Plurite, Satco, and Eiko are all commonly cross-shopped in LED tube retrofit work, but the right choice depends on project priorities more than brand name alone. Osram is often considered when buyers want a widely recognised lighting brand and a familiar commercial retrofit option. Satco is commonly evaluated for broad lamp selection and practical coverage across many everyday replacement applications. Eiko is frequently chosen in maintenance and replacement channels where buyers want dependable access to common lamp formats. Plurite may be a suitable option for standard retrofit work where value and straightforward replacement are the main goals. For contractors maintaining an existing site standard, matching the installed lamp family may be the best choice for consistency in colour, appearance, and future stocking. For bid work, it is often smarter to compare wiring style, voltage compatibility, warranty support, and availability rather than assuming one brand is automatically superior in every fixture type.
Related Products
LED tube ballast bypass projects are often purchased alongside replacement lampholders or tombstones, wire connectors, fixture labels, branch-rated disconnecting means where required by project scope, and test instruments for voltage verification. Buyers may also compare ballast-compatible LED tubes, universal LED tubes, full LED strip fixtures, LED wrap fixtures, and LED panel retrofits when deciding whether to relamp, rewire, or replace the entire luminaire. In older fluorescent systems, it is also common to inspect lenses, reflectors, and fixture grounding hardware during the same visit. For larger maintenance programs, standardising related consumables and replacement parts can reduce truck stock complexity and speed up future service calls.
Frequently Asked Questions
What does ballast bypass mean on an LED tube?
It means the fluorescent ballast is removed or disconnected and the LED tube is powered directly from the supply wiring according to the lamp's specified wiring method.
Are ballast bypass LED tubes better than ballast-compatible tubes?
They are often better for long-term maintenance because the ballast is no longer a failure point. Ballast-compatible tubes can reduce initial labour, but they still depend on ballast condition and compatibility.
Do I need shunted or non-shunted tombstones?
That depends on the lamp design. Many single-end powered lamps require non-shunted lampholders, while double-end powered lamps may use a different arrangement. Always verify against the lamp instructions before ordering or installing.
Can I use ballast bypass LED tubes in T12 fixtures?
Often yes, provided the lamp is intended for that application and the fixture can be rewired correctly. Base type, physical fit, voltage, and lampholder condition still need to be checked.
Is a ballast bypass retrofit a full fixture replacement?
No. It is usually a fixture modification that keeps the existing housing and rewires it for direct-wire LED lamps. If the fixture is in poor condition, a full replacement may be the better option.
What should I confirm before buying LED tube ballast bypass lamps?
Confirm lamp length, tube type, input voltage, colour temperature, lumen output, wiring style, base compatibility, and whether the fixture's lampholders are suitable for the intended retrofit.










































