Authorized ABB Power Distribution Wholesaler for British Columbia | Qualified Contractors May Be Eligible for Additional ABB Pricing Programs
Products: 121 of 21
    • Stock in Calgary
        Click the image to back order this item from the product page
        • Stock in Calgary
            Click the image to back order this item from the product page
            • Stock in Calgary
                Click the image to back order this item from the product page
                • Stock in Calgary
                    Click the image to back order this item from the product page
                    • Stock in Calgary
                        Click the image to back order this item from the product page
                        • Stock in Calgary
                            Click the image to back order this item from the product page
                            • Stock in Calgary
                                Click the image to back order this item from the product page
                                • Stock in Calgary
                                    Click the image to back order this item from the product page
                                    • Stock in Calgary
                                        Click the image to back order this item from the product page
                                        • Stock in Calgary
                                            Click the image to back order this item from the product page
                                            • Stock in Calgary
                                                Click the image to back order this item from the product page
                                                • Stock in Calgary
                                                    Click the image to back order this item from the product page
                                                    • Stock in Calgary
                                                        Click the image to back order this item from the product page
                                                        • Stock in Calgary
                                                            Click the image to back order this item from the product page
                                                            • Stock in Calgary
                                                                Click the image to back order this item from the product page
                                                                • Stock in Calgary
                                                                    Click the image to back order this item from the product page
                                                                    • Stock in Calgary
                                                                        Click the image to back order this item from the product page
                                                                        • Stock in Calgary
                                                                            Click the image to back order this item from the product page
                                                                            • Stock in Calgary
                                                                                Click the image to back order this item from the product page
                                                                                • Stock in Calgary
                                                                                    Click the image to back order this item from the product page
                                                                                    • Stock in Calgary
                                                                                        Click the image to back order this item from the product page

                                                                                      Quick Decision Summary

                                                                                      • Check the base first. PL lamps are not all interchangeable, and pin configuration must match the fixture or retrofit plan.
                                                                                      • For LED retrofit work, confirm whether the lamp is ballast compatible, ballast bypass, or universal before ordering.
                                                                                      • Match colour temperature and light output to the space so relamping does not create uneven appearance across a site.
                                                                                      • For maintenance-heavy buildings, LED PL replacements can reduce lamp change frequency compared with CFL.
                                                                                      • For existing fluorescent installations, verify fixture condition, ballast age, and local retrofit practice before choosing lamp-only replacement.

                                                                                      LED PL/CFL lamps are commonly used in commercial downlights, wall fixtures, corridor lighting, washrooms, offices, and other compact fluorescent applications where space is limited and service access may be awkward. For electricians, maintenance teams, and purchasing staff, the main buying issues are usually base compatibility, ballast strategy, light level, colour match, and whether the job calls for a quick relamp or a more permanent LED conversion. This category covers both traditional CFL style lamps and LED replacement options used in the same general fixture families.

                                                                                      What Are LED PL/CFL Lamps?

                                                                                      LED PL/CFL lamps are compact lamps designed for fixtures that use plug-in or compact fluorescent form factors rather than standard screw-base lamps. Traditional CFL PL lamps use fluorescent technology and typically require a compatible ballast. LED PL replacements are built to fit many of the same fixture types but may operate in different ways depending on design. Some run from an existing compatible ballast, some require ballast bypass and direct line voltage wiring, and some are intended to work in more than one configuration. In practice, this category is often used when maintaining older commercial lighting systems or upgrading them without replacing every fixture body.

                                                                                      Where Are LED PL/CFL Lamps Used?

                                                                                      These lamps are widely used in commercial and institutional spaces such as offices, apartment common areas, schools, healthcare support spaces, retail back rooms, washrooms, stairwells, and hospitality properties. They are especially common in recessed downlights, compact wall sconces, and ceiling fixtures originally designed around CFL technology. LED PL replacements are often chosen where fixture replacement would be disruptive, where ceiling access is limited, or where a site has many identical fixtures and wants to reduce maintenance calls. They can also be useful in phased retrofit projects where a full fixture change is not yet budgeted.

                                                                                      How To Choose LED PL/CFL Lamps

                                                                                      Start with the existing lamp code, base style, and pin count. A lamp that looks similar may still be electrically or mechanically incompatible. Next, decide whether the project is staying with CFL or moving to LED. If moving to LED, determine the retrofit method: ballast compatible for faster relamping where approved and practical, or ballast bypass where the goal is to remove a future ballast failure point. Then compare nominal wattage, light output, colour temperature, and orientation. In downlights and horizontal fixtures, lamp geometry matters because some LED replacements distribute light differently than CFL. Also check enclosed fixture suitability, operating temperature range, and whether the site needs consistent appearance across multiple rooms or floors. For larger maintenance programs, standardising one colour temperature and one retrofit method can simplify future service.

                                                                                      Trade Rules Of Thumb

                                                                                      For relamping projects, a practical rule of thumb is to inspect ballast age before choosing ballast compatible LED lamps. If ballasts are already near the end of service life, bypass retrofits may reduce repeat maintenance. Another common rule is to keep colour temperature consistent within a visible area, since mixing 3000K, 3500K, and 4000K lamps in corridors or open office areas is usually noticeable. In commercial interiors, 3000K is often used for warmer hospitality or residential common areas, while 3500K and 4000K are common in offices, washrooms, and utility spaces. For maintenance stock, it is usually better to carry fewer lamp families with clearly labelled base and wiring type than many near-matches that increase service call errors. These are practical guidelines only and not a substitute for manufacturer instructions or applicable electrical requirements.

                                                                                      Sizing Guidelines

                                                                                      When replacing CFL with LED PL lamps, do not size by wattage alone. Compare approximate delivered light level, beam pattern or distribution, and fixture performance. A lower wattage LED lamp may still provide acceptable or better usable light, but this depends on the fixture optics and lamp orientation. For corridor and washroom relamps, matching the existing perceived brightness is often more important than matching nameplate wattage. In downlights, verify that the lamp length and body shape fit the housing and do not interfere with trim or reflector components. If the fixture is part of an emergency lighting circuit, switching control system, or sensor-controlled installation, confirm compatibility before ordering in volume. All sizing and retrofit decisions should be checked against the lamp and fixture documentation and local code requirements.

                                                                                      Common Installation Practices

                                                                                      On service calls, technicians usually begin by identifying the existing lamp family, base, and ballast arrangement before selecting a replacement. For CFL-to-CFL relamping, the normal practice is to replace failed lamps with the same type and confirm ballast condition if failures are frequent. For LED retrofit work, common practice is either to use a listed ballast compatible lamp with a known compatible ballast, or to disconnect and remove or bypass the ballast in accordance with the lamp instructions and site standards. Many contractors label retrofitted fixtures to show the new lamp type and wiring method, which helps future maintenance. It is also common to relamp by area rather than one lamp at a time so colour shift and uneven ageing are less visible. Always de-energise equipment and follow manufacturer instructions and applicable Canadian electrical requirements.

                                                                                      Common Mistakes

                                                                                      One common mistake is assuming all PL lamps with similar shapes use the same base. Another is ordering LED replacements without confirming whether the existing ballast is compatible, still present, or already failed. Buyers also sometimes focus only on wattage and overlook colour temperature, lamp orientation, or physical clearance inside the fixture. In multi-fixture spaces, mixing different lamp brands or colour temperatures can create visible inconsistency. Another frequent issue is using a quick lamp retrofit in fixtures that are already degraded, yellowed, or mechanically damaged, where full fixture replacement may be the better long-term choice. For maintenance departments, poor labelling after ballast bypass work can create confusion and unsafe assumptions during future service.

                                                                                      Brand Comparisons

                                                                                      Osram is widely recognised and often selected where buyers want a familiar commercial lighting brand with broad retrofit acceptance and consistent specification support. Satco is commonly cross-shopped for breadth of lamp offerings and practical replacement options across many everyday maintenance applications. Eiko is often considered for service and replacement work where maintenance teams need a broad lamp catalogue and dependable access to common formats. Plurite can be a suitable option for standard relamping and retrofit needs where value and availability are important. In many projects, the right brand choice depends less on name alone and more on whether the exact lamp type, base, ballast strategy, and colour match the installed condition. Where a building already uses one brand across many fixtures, staying with the same family may simplify appearance and maintenance, but an equivalent alternative may also be suitable if compatibility and output are confirmed.

                                                                                      Related Products

                                                                                      Related products often include electronic ballasts, lampholders, retrofit labels, downlight trims, occupancy sensors, emergency lighting components, and complete LED fixture replacements. For larger upgrade work, buyers may also compare integrated LED downlights or panel fixtures instead of continuing with lamp-based maintenance. If repeated lamp or ballast failures are occurring, it may be worth reviewing the fixture condition, switching frequency, ambient temperature, and branch circuit arrangement rather than replacing lamps alone.

                                                                                      Frequently Asked Questions

                                                                                      Can I replace any CFL PL lamp with an LED PL lamp?

                                                                                      No. You need to confirm the base type, pin configuration, physical fit, and electrical method. Some LED PL lamps need a compatible ballast, while others require ballast bypass and direct wiring.

                                                                                      Is ballast compatible or ballast bypass better?

                                                                                      It depends on the job. Ballast compatible lamps can speed up relamping when the existing ballast is approved and in good condition. Ballast bypass can reduce future ballast-related maintenance, but it requires fixture rewiring in accordance with the lamp instructions.

                                                                                      Should I keep using CFL lamps in older fixtures?

                                                                                      That can still make sense for short-term maintenance, small one-off repairs, or sites standardised around existing fluorescent stock. For buildings with frequent service calls, LED retrofit often makes more sense because lamp replacement intervals are usually longer.

                                                                                      What colour temperature should I choose for commercial spaces?

                                                                                      3000K is often used where a warmer appearance is preferred, such as residential common areas or hospitality spaces. 3500K and 4000K are common in offices, corridors, washrooms, and utility areas. Match existing areas where visual consistency matters.

                                                                                      Do I need to replace all lamps in an area at once?

                                                                                      For visible public or tenant-facing spaces, that is often the better practice. Group relamping helps avoid mismatched colour, uneven light levels, and patchy appearance caused by mixing old and new lamps.

                                                                                      What should I verify before ordering LED PL lamps for a large site?

                                                                                      Check the existing lamp code, base, pin count, ballast type, fixture condition, colour temperature target, and whether the site wants ballast compatible or bypass retrofits. A small field test on representative fixtures can prevent ordering errors.

                                                                                      LED PL/CFL Lamps

                                                                                      :

                                                                                      Clear
                                                                                      Clear

                                                                                      Footer navigation