MCCB UL 489 M2N 250 A Frame Size 10 kA @ 480 Vac 250A 1P Lug Line/Load Side
M2N250T1L
Out of stock441 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 30A 3-Pole 35kA @ 480VAC · 150A Frame with Line/Load Lugs · Noark Electrical M1S30T3L
M1S30T3L
3 In Ontario Factory Warehouse As Of Sep 3rd 2026346 – Loyalty RewardsMolded Case Circuit Breaker · 60A 3-Pole 35kA @ 480VAC · 150A Frame with Line/Load Lugs · Noark Electric M1S60T3L
M1S60T3L
Available For Back-Order346 – Loyalty RewardsMolded Case Circuit Breaker · 100A, 3-Pole, 35kA @ 480VAC · Line/Load Lugs, Adjustable Thermal Trip · Noark Electrical M1S100T3L
M1S100T3L
Available For Back-Order346 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 150A 3-Pole 35kA @ 480VAC · Thermal-Magnetic with Line/Load Lugs · Noark Electric M1S150T3L
M1S150T3L
16 In Ontario Factory Warehouse As Of Sep 3rd 2026508 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 175A 3-Pole 35kA at 480Vac · 250A M2 Frame with Line/Load Lugs · Noark Electrical M2S175T3L
M2S175T3L
5 In Ontario Factory Warehouse As Of Sep 3rd 2026789 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 200A 3-Pole 250A Frame 35kA at 480V AC · Line and Load Lugs · Noark Electrical M2S200T3L
M2S200T3L
3 In Ontario Factory Warehouse As Of Sep 3rd 2026789 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 225A 3-Pole 35kA at 480VAC · Line and Load Lugs Included · Noark Electric M2S225T3L
M2S225T3L
45 In Ontario Factory Warehouse As Of Sep 3rd 2026789 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 250A, 3-Pole, 35kA @ 480Vac · Line/Load Lugs · Noark Electric M2S250T3L
M2S250T3L
29 In Ontario Factory Warehouse As Of Sep 3rd 2026910 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 300A 3-Pole · 42kA @ 480VAC · Lug Line/Load Noark Electric M3S300T3L
M3S300T3L
6 In Ontario Factory Warehouse As Of Sep 3rd 20261153 – Loyalty RewardsMolded Case Circuit Breaker · 350A 3P 400A Frame · 42kA @ 480Vac with Lug Line/Load · Noark Electrical M3S350T3L
M3S350T3L
Available For Back-Order1153 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 400A 3-Pole 42kA at 480Vac · Thermal-Magnetic with Line/Load Lugs · Noark Electrical M3S400T3L
M3S400T3L
9 In Ontario Factory Warehouse As Of Sep 3rd 20261153 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 400A 3-Pole 600A Frame · 42kA @ 480V AC with Line/Load Lugs · Noark Electrical M4S400T3L
M4S400T3L
3 In Ontario Factory Warehouse As Of Sep 3rd 20262692 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 500A, 3-Pole, 600A Frame, 42kA @ 480VAC, Line/Load Lugs · Noark Electric M4S500T3L
M4S500T3L
2 In Ontario Factory Warehouse As Of Sep 3rd 20262692 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 600A 3-Pole 42kA @ 480VAC · Lug Line/Load Side, Thermal-Magnetic Trip · Noark Electrical M4S600T3L
M4S600T3L
7 In Ontario Factory Warehouse As Of Sep 3rd 20262692 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 30A, 3-Pole, 65kA @ 480VAC · Lug Line/Load Side · Noark Electric M1N30T3L
M1N30T3L
37 In Ontario Factory Warehouse As Of Sep 3rd 2026384 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 60A 3-Pole 65kA @ 480V AC · Lug Line/Load Side, 150A Frame · Noark Electrical M1N60T3L
M1N60T3L
140 In Ontario Factory Warehouse As Of Sep 3rd 2026384 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 100A · 3-Pole · 65kA at 480VAC · Line/Load Lugs · Noark Electric M1N100T3L
M1N100T3L
80 In Ontario Factory Warehouse As Of Sep 3rd 2026384 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 150A 3-Pole · 65kA at 480VAC with Lug Line/Load · Noark Electric M1N150T3L
M1N150T3L
86 In Ontario Factory Warehouse As Of Sep 3rd 2026581 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 175A 3-Pole 250A Frame 65kA @ 480VAC · Line/Load Lugs · Noark Electric M2N175T3L
M2N175T3L
8 In Ontario Factory Warehouse As Of Sep 3rd 2026855 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 200A, 3-Pole, 250A Frame, 65kA @ 480V AC, Lug Line/Load · Noark Electric M2N200T3L
M2N200T3L
19 In Ontario Factory Warehouse As Of Sep 3rd 2026855 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 225A 3-Pole 250A Frame 65kA @ 480VAC · Line/Load Lugs · Noark Electric M2N225T3L
M2N225T3L
37 In Ontario Factory Warehouse As Of Sep 3rd 2026855 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 300A 3-Pole 65kA @ 480V AC · 400A Frame with Lug Terminals · Noark Electric M3N300T3L
M3N300T3L
7 In Ontario Factory Warehouse As Of Sep 3rd 20261267 – Loyalty Rewards- Factory Stock in Ontario
Moulded Case Circuit Breaker · 350A, 3-Pole, 400A Frame, 65kA @ 480Vac, Lug Line/Load · Noark Electric M3N350T3L
M3N350T3L
20 In Ontario Factory Warehouse As Of Sep 3rd 20261267 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 400A 3-Pole 65kA @ 480VAC · Line/Load Lugs, Adjustable Thermal-Magnetic Trip · Noark Electrical M3N400T3L
M3N400T3L
88 In Ontario Factory Warehouse As Of Sep 3rd 20261267 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 400A, 3-Pole, 65kA @ 480VAC · Line/Load Lugs, Thermal-Magnetic Trip · Noark Electric M4N400T3L
M4N400T3L
1 In Ontario Factory Warehouse As Of Sep 3rd 20262928 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 250A 3-Pole · 65kA at 480VAC · Line/Load Lugs · Noark Electrical M2N250T3L
M2N250T3L
42 In Ontario Factory Warehouse As Of Sep 3rd 20261069 – Loyalty RewardsMolded Case Circuit Breaker · 500A 3-Pole 65kA @ 480VAC · Lug Line/Load Side · Noark Electric M4N500T3L
M4N500T3L
Available For Back-Order2928 – Loyalty Rewards- Factory Stock in Ontario
Moulded Case Circuit Breaker · 600A, 3-Pole, 65kA @ 480VAC · Line/Load Lugs, Adjustable Thermal-Magnetic Trip · Noark M4N600T3L
M4N600T3L
4 In Ontario Factory Warehouse As Of Sep 3rd 20262928 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 30A · 3-Pole · 100kA at 480Vac · 150A Frame · Lug Line/Load · Noark Electric M1H30T3L
M1H30T3L
5 In Ontario Factory Warehouse As Of Sep 3rd 2026498 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 150A 3-Pole 100kA at 480VAC · Lug Line/Load, Adjustable Thermal-Magnetic · Noark M1H150T3L
M1H150T3L
27 In Ontario Factory Warehouse As Of Sep 3rd 2026728 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 100A, 3-Pole, 100 kA @ 480 Vac · Lug Line/Load, 150A Frame · Noark Electrical M1H100T3L
M1H100T3L
30 In Ontario Factory Warehouse As Of Sep 3rd 2026498 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 60A 3-Pole · 150A Frame, 100kA @ 480VAC, Line/Load Lugs · Noark Electrical M1H60T3L
M1H60T3L
31 In Ontario Factory Warehouse As Of Sep 3rd 2026498 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 175A 3-Pole 250A Frame · 100kA at 480Vac with Line/Load Lugs · Noark Electric M2H175T3L
M2H175T3L
1 In Ontario Factory Warehouse As Of Sep 3rd 20261112 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 200A 3-Pole 250A Frame · 100kA at 480V AC with Line and Load Lugs · Noark Electric M2H200T3L
M2H200T3L
9 In Ontario Factory Warehouse As Of Sep 3rd 20261112 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 225A 3-Pole · 250A Frame with Line/Load Lugs · Noark Electrical M2H225T3L
M2H225T3L
3 In Ontario Factory Warehouse As Of Sep 3rd 20261112 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 250A 3P 100kA @ 480VAC · Line/Load Lugs · Noark M2H250T3L
M2H250T3L
9 In Ontario Factory Warehouse As Of Sep 3rd 20261336 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 400A, 3-Pole, 100kA @ 480VAC · Lug Line/Load Side, 400A Frame · Noark Electrical M3H400T3L
M3H400T3L
6 In Ontario Factory Warehouse As Of Sep 3rd 20261646 – Loyalty RewardsMolded Case Circuit Breaker · 400A 3P 600A Frame · 100kA @ 480Vac Thermal-Magnetic · Noark Electrical M4H400T3L
M4H400T3L
Available For Back-Order3807 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 600A, 3P, 100kA @ 480Vac · Thermal-Magnetic Trip with Lug Terminals · Noark Electric M4H600T3L
M4H600T3L
3 In Ontario Factory Warehouse As Of Sep 3rd 20263807 – Loyalty Rewards
Quick Decision Summary
- Choose molded case circuit breakers for enclosure kits when you need branch, feeder, or equipment protection in a dedicated enclosure rather than a full panelboard.
- Start with the actual enclosure kit and bus or mounting arrangement first. Mechanical fit, line and load termination style, and accessory compatibility matter as much as amp rating.
- Check poles, voltage class, interrupting rating, trip unit type, and available fault current before ordering. A breaker that fits physically may still be wrong electrically.
- Noark is a practical option for many standard commercial and industrial builds, especially where a complete matched assembly is preferred.
- For replacements or retrofit work, matching the installed system family is often the safest path. Do not assume one MCCB line is interchangeable with another.
Molded case circuit breakers for enclosure kits are used where you need a compact overcurrent protective device in a standalone enclosure, control assembly, disconnect arrangement, or custom distribution build. For electricians, maintenance teams, OEM panels, and facility upgrades, the real buying decision is usually not just breaker amperage. It is whether the breaker matches the enclosure kit, available fault current, conductor size, system voltage, and the service conditions of the installation. This category is most useful when you are building or servicing enclosed breaker assemblies and need a practical way to compare fit, protection level, and brand family.
What Are Molded Case Circuit Breakers (for Enclosure Kits)?
Molded case circuit breakers, often called MCCBs, are resettable overcurrent devices housed in a molded insulating case. In enclosure kit applications, they are mounted into a dedicated enclosure or breaker kit rather than installed as a plug-in branch breaker in a residential loadcentre. They are commonly used for feeder protection, equipment isolation with overcurrent protection, motor and machinery supply, HVAC distribution, pump panels, service sub-distribution, and custom control assemblies. Depending on the product family, they may be available in thermal-magnetic or electronic trip versions, with different frame sizes, interrupting ratings, lug options, shunt trips, auxiliary contacts, and handle mechanisms.
Where Are Molded Case Circuit Breakers (for Enclosure Kits) Used?
These breakers are commonly used in commercial buildings, light industrial facilities, agricultural service buildings, mechanical rooms, rooftop equipment feeds, pump and irrigation systems, generator accessory assemblies, and OEM equipment packages. They are also common where a contractor needs a simple enclosed breaker rather than a larger panelboard section. In maintenance work, enclosure-kit MCCBs are often selected for replacing damaged enclosed breakers, adding local disconnecting means with overcurrent protection, or building a compact feeder takeoff. In industrial settings, they are often chosen where a fusible switch is not required and where resettable protection and accessory options are useful.
How To Choose Molded Case Circuit Breakers (for Enclosure Kits)
Start with the enclosure kit and the exact breaker family it is designed to accept. Then confirm the required amp rating, number of poles, system voltage, and interrupting rating. After that, review conductor range, lug type, line-side and load-side access, and whether field-installed accessories are needed. If the breaker will feed motors, HVAC equipment, compressors, welders, or other loads with higher inrush, check that the trip characteristics suit the application. For service and retrofit work, verify the available fault current and the assembly listing requirements. If the breaker is part of a custom build, also consider door hardware, rotary handle requirements, lockout needs, and whether shunt trip or auxiliary indication is required for controls integration.
Trade Rules Of Thumb
As a practical rule, choose the enclosure family first and the breaker second, because enclosure compatibility is often the limiting factor. For feeder and equipment protection, many buyers work backward from the conductor ampacity and the actual load profile, then confirm the breaker trip style is suitable. Where available fault current is uncertain, do not guess - obtain the fault study, utility data, or engineering basis before selecting interrupting rating. For motor and compressor loads, nuisance tripping can occur if a standard thermal-magnetic breaker is selected too simplistically, so review starting current and equipment instructions. For retrofit work, if the existing installation is built around a specific manufacturer family, staying within that family is often faster and lower risk than attempting a cross-brand substitution.
Sizing Guidelines
Typical sizing starts with the calculated load, conductor size, ambient conditions, duty cycle, and the type of connected equipment. For continuous loads, electricians commonly review whether the circuit should be sized above the actual running current rather than matching it exactly. For feeder applications, confirm the breaker rating works with the conductor ampacity and the equipment termination ratings. For motor-related loads, breaker sizing may differ from conductor sizing because starting current and protective device rules are not the same as simple resistive loads. Interrupting rating must be equal to or greater than the available fault current at the point of installation. These are general buying guidelines only - final sizing and protection selection must follow the Canadian Electrical Code, equipment markings, and the authority having jurisdiction.
Common Installation Practices
In enclosure kit assemblies, common practice is to verify the breaker catalog family, mounting hardware, handle mechanism, and lug kit before arriving on site. Installers typically confirm conductor bend space, wire entry direction, and whether the enclosure allows practical torque access. Line and load orientation should follow the manufacturer instructions for the specific breaker and enclosure combination. Torque values should be taken from the breaker or lug documentation, not from memory. In custom assemblies, labelling, lockout provisions, and clear identification of source and load are especially important. Where accessories such as shunt trip, undervoltage release, or auxiliary contacts are used, control wiring should be checked against the exact accessory diagram for that breaker family.
Common Mistakes
A common mistake is assuming any MCCB with the same amp rating will fit the same enclosure kit. Another is focusing on amperage while overlooking interrupting rating, voltage class, or accessory compatibility. Buyers also sometimes miss lug range and conductor material compatibility, especially when larger copper or aluminium conductors are involved. In retrofit work, one of the biggest errors is treating a different brand as a direct substitute without confirming listing, fit, and performance. On the installation side, insufficient bend space, poor handle alignment, and failure to torque terminations correctly are recurring problems. For equipment loads, nuisance tripping is often caused by selecting a breaker on nameplate current alone without considering inrush or duty.
Brand Comparisons
Noark is commonly considered by buyers looking for a practical MCCB solution for new assemblies, standard commercial work, and value-conscious industrial projects. It can be a sensible choice when you want a matched breaker and enclosure approach and do not need to stay within an existing installed legacy family. Square D, Eaton, Siemens, and ABB are widely recognized in the broader market and are often preferred where a facility standard already exists, where maintenance teams stock that family, or where a direct match to installed gear reduces downtime and approval risk. Homeline is better known in residential loadcentre contexts than in the heavier MCCB enclosure category, so it is usually cross-shopped less directly here. In general, if you are building new and the enclosure kit is designed around Noark, Noark may be a good fit for many standard applications. If you are replacing within an existing branded system, matching the installed manufacturer is often the better decision.
Related Products
Related products often include breaker enclosures, enclosure kits, rotary handles, flange handles, shunt trip accessories, auxiliary contacts, undervoltage releases, mechanical interlocks, power distribution blocks, feeder conductors, compression lugs, grounding hardware, and control transformers where accessory circuits are required. Depending on the build, buyers may also need wireway, DIN rail components, terminal blocks, surge protection, contactors, and disconnect accessories. For field installation, proper labels, lockout hardware, and conductor identification materials are also commonly purchased with enclosed breaker assemblies.
Frequently Asked Questions
Can I use any molded case circuit breaker in any enclosure kit?
No. Enclosure kits are usually designed around specific breaker families, frame sizes, mounting patterns, and handle mechanisms. Always confirm the exact compatibility before ordering.
What matters more, amp rating or interrupting rating?
Both matter, but interrupting rating is a critical safety and compliance issue. The breaker amp rating must suit the load and conductors, while the interrupting rating must be adequate for the available fault current at the installation point.
Is Noark a reasonable choice for new enclosure-kit builds?
Yes, for many standard commercial and industrial applications it can be a practical choice, especially when the enclosure kit and accessories are intended for that breaker family. It is less suitable as a casual substitute into another manufacturer's assembly without proper confirmation.
Can I replace a Square D, Eaton, Siemens, or ABB breaker with Noark if the amperage matches?
Not automatically. Matching amperage alone does not confirm mechanical fit, listing, interrupting rating, trip behaviour, or accessory compatibility. Replacement decisions should be based on the exact assembly and approved application.
Do I need a thermal-magnetic or electronic trip breaker?
That depends on the application. Thermal-magnetic breakers are common for many straightforward feeder and equipment circuits, while electronic trip options may be preferred where adjustability, coordination, or more detailed protection settings are needed.
Are these breakers suitable for motor loads?
They can be, but motor circuits need more careful review than simple resistive loads. Starting current, overload protection method, and equipment instructions all affect the correct selection.
What should I verify before ordering for a retrofit job?
Verify the existing enclosure or assembly brand, breaker family, frame size, poles, voltage, interrupting rating, lug requirements, handle style, and any accessories. Retrofit delays often come from missing one of these details.