- Out of stock1719 – Loyalty Rewards
MCCB UL 489 M2N 250 A Frame Size 10 kA @ 480 Vac 200A 1P Lug Line/Load Side
M2N200T1L
Out of stock353 – Loyalty Rewards- Factory Stock in Ontario
MCCB UL 489 M2S 250 A Frame Size 35 kA @ 480 Vac 150A 2P Lug Line/Load Side
M2S150T22L
Out of stock419 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 200A 2-Pole · 35 kA at 480 Vac UL 489 · Noark Electric M2S200T22L
M2S200T22L
12 In Ontario Factory Warehouse As Of Nov 18th 2026419 – Loyalty RewardsMolded Case Circuit Breaker · 250A, 2-Pole, 35 kA @ 480 Vac, Lug Line/Load · UL 489 Listed · Noark M2S250T22L
M2S250T22L
Available For Factory Direct Order483 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 175A, 2-Pole, 35 kA @ 480 Vac, 250A Frame · Lug Line/Load, UL 489 · Noark Electric M2S175T22L
M2S175T22L
26 In Ontario Factory Warehouse As Of Nov 18th 2026419 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 125A, 2-Pole, 35 kA @ 480 VAC · UL 489, Lug Line/Load · Noark Electric M2S125T22L
M2S125T22L
18 In Ontario Factory Warehouse As Of Nov 18th 2026419 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 125A, 3-Pole, 35kA @ 480VAC, Lug Line/Load · Noark Electric M2S125T3L
M2S125T3L
1 In Ontario Factory Warehouse As Of Nov 18th 2026789 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 150A 3-Pole · 100kA at 480V AC Interrupting · Noark M2H150T3L
M2H150T3L
10 In Ontario Factory Warehouse As Of Nov 18th 20261112 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 150A 3-Pole · 35 kA at 480 VAC, Lug Line/Load · Noark Electric M2S150T3L
M2S150T3L
14 In Ontario Factory Warehouse As Of Nov 18th 2026789 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 225A 2-Pole 250AF · 35 kA at 480 Vac UL 489 Lug Line/Load Side · Noark M2S225T22L
M2S225T22L
8 In Ontario Factory Warehouse As Of Nov 18th 2026419 – Loyalty Rewards- Factory Stock in Ontario
Molded case circuit breaker · 125A, 3-pole, 65kA at 480V AC · 250A frame with line/load lugs · Noark M2N125T3L
M2N125T3L
2 In Ontario Factory Warehouse As Of Nov 18th 2026855 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 200A, 2-Pole, 250A Frame, 65 kA @ 480 Vac · Thermal-Magnetic, Lug Line/Load · Noark Electric M2N200T22L
M2N200T22L
4 In Ontario Factory Warehouse As Of Nov 18th 2026585 – Loyalty Rewards- Factory Stock in Ontario
Molded case circuit breaker · 100A, 3-pole, 35 kA at 480 VAC · Lug line/load side · Noark Electric M2S100T3L
M2S100T3L
2 In Ontario Factory Warehouse As Of Nov 18th 2026789 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 150A, 3-Pole, 250A Frame · 65kA @ 480VAC, Lug Line/Load · Noark M2N150T3L
M2N150T3L
13 In Ontario Factory Warehouse As Of Nov 18th 2026855 – Loyalty Rewards- Factory Stock in Ontario
Molded Case Circuit Breaker · 100A · 3-Pole · 65kA at 480VAC · Lug Line/Load · Noark Electric M2N100T3L
M2N100T3L
10 In Ontario Factory Warehouse As Of Nov 18th 2026855 – Loyalty Rewards- Factory Stock in Ontario
Ground fault molded case circuit breaker · 100A · 100kA at 480VAC · 3-pole lug line/load · Noark Electric M2GH100T3L
M2GH100T3L
1 In Ontario Factory Warehouse As Of Nov 18th 20261719 – Loyalty Rewards- Factory Stock in Ontario
Ground Fault Protection Molded Case Circuit Breaker · 200A · 100kA at 480Vac · Line and Load Lugs · Noark M2GH200T3L
M2GH200T3L
1 In Ontario Factory Warehouse As Of Nov 18th 20261719 – Loyalty Rewards- Factory Stock in Ontario
Ground fault molded case circuit breaker · 200A, 35kA at 480Vac, 3-pole, line/load lugs · UL 489 M2 frame · Noark Electric M2GS200T3L
M2GS200T3L
1 In Ontario Factory Warehouse As Of Nov 18th 20261219 – Loyalty Rewards- Factory Stock in Ontario
Ground fault protection molded case circuit breaker · 100A · 35kA at 480Vac · Line/load lugs · Noark Electric M2GS100T3L
M2GS100T3L
1 In Ontario Factory Warehouse As Of Nov 18th 20261219 – Loyalty Rewards
Quick Decision Summary
- M2 Series molded case breakers are typically chosen for feeder, distribution, and equipment protection where higher interrupting capacity and adjustable trip options may be needed beyond a small branch breaker.
- Key buying factors are frame size, ampere rating, poles, interrupting rating, trip unit type, mounting format, and accessory requirements such as auxiliary contacts, shunt trips, or undervoltage release.
- For replacement work, confirm the exact panelboard or switchboard compatibility, terminal range, and available fault current before ordering.
- For new work, MCCB selection should match the system voltage, conductor sizing, coordination goals, and the actual load profile rather than only the nameplate amperage.
- Noark is commonly considered where buyers want a practical MCCB option for standard commercial and industrial applications, but matching an existing installed platform may still be the better choice on service and retrofit jobs.
The Noark M2 Series Molded Case Breaker category is aimed at contractors, panel builders, maintenance teams, and purchasing staff who need dependable overcurrent protection for distribution and equipment circuits. In most projects, the real decision is not simply breaker amperage. It is whether the breaker fits the available fault current, enclosure or gear arrangement, trip characteristics, and accessory package needed for the job. For retrofit and service work in Canada, always verify equipment approval, mounting details, and application suitability before substituting any breaker platform.
What Are M2 Series Molded Case Breakers?
M2 Series molded case breakers are MCCBs used to protect conductors, feeders, panels, machinery, and other electrical equipment from overloads and short circuits. Compared with small residential plug-in breakers, MCCBs are generally used where the system is larger, the available fault current is higher, or the application needs more selection flexibility. Depending on the exact model, an MCCB platform may offer thermal-magnetic or electronic trip behaviour, multiple frame sizes, and field-installed accessories for control and indication. In practical trade use, these breakers are often specified for commercial services, distribution sections, motor-related equipment, HVAC assemblies, and OEM control panels.
Where Are M2 Series Molded Case Breakers Used?
These breakers are commonly used in commercial buildings, light industrial facilities, agricultural service equipment, mechanical rooms, pump systems, rooftop units, distribution panels, and machinery disconnecting means. They are a common fit where a branch circuit breaker is not enough, but a full power breaker or larger switchgear solution is unnecessary. Typical use cases include feeder protection to subpanels, protection for larger HVAC loads, panelboard mains, equipment disconnect sections, and OEM assemblies. In maintenance environments, they are also used as replacement breakers where the original design already uses an MCCB format and the replacement has been properly confirmed for the equipment.
How To Choose M2 Series Molded Case Breakers
Start with the electrical basics: system voltage, frequency, number of poles, and required ampere rating. Then check the available fault current at the installation point and make sure the breaker interrupting rating is adequate. After that, review the trip style needed for the load. Standard thermal-magnetic protection may suit many feeder and equipment applications, while more adjustable trip behaviour may be preferred where coordination or load characteristics are more demanding. Also confirm the frame size, terminal conductor range, line and load connection style, and whether the job needs accessories such as auxiliary contacts, alarm contacts, shunt trip, undervoltage release, rotary handle, or door-coupling hardware. For replacement work, physical fit alone is not enough. The breaker must be suitable for the specific equipment and application.
Trade Rules Of Thumb
As a typical rule of thumb, MCCBs are often selected when the job moves beyond small final branch circuits and into feeder, distribution, or equipment protection with higher available fault current or accessory needs. Another practical rule is to treat interrupting rating as a first-pass filter, not an afterthought. If the fault duty is wrong, the rest of the selection does not matter. For motor and equipment loads, do not assume a breaker sized close to running current will always be suitable, because startup current and inrush can change the trip behaviour significantly. For retrofit jobs, if the site already uses a specific breaker family from Square D, Eaton, Siemens, or ABB, matching the installed platform may reduce field issues, spare parts confusion, and approval questions. These are practical buying rules only, not code requirements.
Sizing Guidelines
Breaker sizing should be based on the actual load calculation, conductor ampacity, equipment nameplate data, and the protection method required by the applicable Canadian code and equipment documentation. As a general guide, feeder breakers are often selected to protect the conductor and downstream equipment together, while equipment breakers may be chosen around the manufacturer-stated maximum overcurrent protection or recommended protective device range. For motor-related applications, running current is only one part of the picture because starting current can be several times higher. For distribution applications, also consider future expansion and coordination with upstream and downstream devices. Always verify conductor temperature rating, lug suitability for copper or aluminium, and enclosure heat conditions before finalising the breaker size.
Common Installation Practices
Common practice is to confirm the breaker catalogue number, trip rating, accessory kit numbers, and mounting arrangement before the gear is shut down. Installers typically verify torque values from the manufacturer instructions, conductor size range, wire type, and whether the lugs are rated for copper, aluminium, or both. In panel and switchboard work, clear labelling of the protected load and any control accessories helps future maintenance. Where shunt trip or undervoltage release is used, control voltage must be checked carefully to avoid nuisance operation or non-operation. After installation, many teams perform insulation checks, mechanical operation checks, and functional trip testing as appropriate to the equipment and site procedures. Installation and commissioning should always follow the manufacturer documentation and local code requirements.
Common Mistakes
One common mistake is choosing by amperage only and overlooking interrupting rating, trip curve behaviour, or accessory compatibility. Another is assuming one MCCB family can be freely substituted for another because the frame looks similar. In retrofit work, that can create approval, fit, or safety problems. Buyers also sometimes miss conductor lug range, especially when larger aluminium conductors are involved. On equipment jobs, a frequent error is ignoring inrush or motor starting current and then dealing with nuisance tripping after startup. Another issue is ordering the breaker but forgetting the handle mechanism, auxiliary contacts, or shunt trip needed to complete the assembly. For service replacements, always confirm the exact application rather than relying on visual similarity or informal cross-reference habits.
Brand Comparisons
Noark is commonly cross-shopped against established names such as Square D, Eaton, Siemens, and ABB in the broader MCCB market. In many standard commercial and industrial applications, Noark may be a practical option when the required ratings, approvals, and accessory set align with the job. Square D and Eaton are often preferred where the site already standardises on those ecosystems or where maintenance teams want continuity with existing installed gear. Siemens and ABB are also common in industrial and OEM environments where matching the existing platform can simplify service and spare management. Homeline is better known as a residential loadcentre line and is generally not the direct comparison point for many MCCB applications. The right choice depends on compatibility, support expectations, installed base, and the exact protection requirement, not just brand familiarity.
Related Products
Products commonly purchased alongside M2 Series molded case breakers include MCCB accessories, shunt trips, undervoltage releases, auxiliary and alarm contacts, rotary handles, enclosure hardware, panelboard and switchboard components, lugs, power distribution blocks, DIN rail control parts, and wire termination products. Depending on the application, buyers may also need control transformers, contactors, overload relays, disconnect switches, surge protection, and labelling supplies. For panel building and service work, it is often worth reviewing the complete assembly bill of material before ordering so the breaker, accessories, and mounting hardware arrive together.
Frequently Asked Questions
What is the difference between an MCCB and a small branch circuit breaker?
An MCCB is generally used for larger or more demanding applications. It often offers higher ampere ranges, higher interrupting ratings, more accessory options, and in some cases more adjustable trip behaviour than a small branch breaker used in light residential panels.
Can I replace another brand of molded case breaker with a Noark M2 breaker?
Not automatically. Replacement suitability depends on the equipment listing, mounting arrangement, electrical ratings, and application details. A breaker should not be substituted only because it appears physically similar.
How do I know what interrupting rating I need?
You need to know the available fault current at the point where the breaker will be installed. The breaker interrupting rating must be adequate for that location. This is a critical safety and compliance check on commercial and industrial jobs.
Are M2 Series breakers suitable for motor loads?
They may be, depending on the exact breaker type, trip characteristics, and the motor application. Motor circuits often need careful review of starting current, overload protection method, and equipment manufacturer requirements before the breaker is selected.
What should I confirm before ordering a replacement MCCB?
Confirm the full breaker catalogue reference, ampere rating, poles, voltage, interrupting rating, trip unit type, accessory requirements, terminal details, and the exact equipment it will be installed in. For replacement work, compatibility and approval matter as much as the electrical rating.