- Available For Back-Order23889 – Loyalty Rewards
Air Circuit Breaker · 800A, 3-Pole, Drawout, Vertical Connection, 2500A Frame, 85kA @ 480VAC · UL 1066 / CSA Approved · Noark Electrical A25R3DV800
A25R3DV800
Available For Back-Order17063 – Loyalty RewardsAir Circuit Breaker · 800A, 2500A Frame, 4-Pole, Fixed Vertical Connection, 85kA @ 480VAC · UL 1066/CSA Approved · Noark Electrical A25R4FV800
A25R4FV800
Available For Back-Order21623 – Loyalty RewardsAir Circuit Breaker · 800A, 2500A Frame, 4-Pole, Drawout, 85kA @ 480VAC · Horizontal Connection · Noark Electrical A25R4DH800
A25R4DH800
Available For Back-Order23889 – Loyalty RewardsAir Circuit Breaker · 800A, 2500A Frame, 3-Pole, Fixed Vertical Connection, 85kA at 480V · Noark Electrical A25R3FV800
A25R3FV800
Available For Back-Order15445 – Loyalty RewardsAir Circuit Breaker · 800A, 2500A Frame, 3-Pole, Drawout, Horizontal Connection, 85kA @ 480VAC · UL 1066 / CSA Approved · Noark Electrical A25R3DH800
A25R3DH800
Available For Back-Order17063 – Loyalty RewardsAir Circuit Breaker · 800A · 2500A frame, 3-pole, fixed horizontal connection, 85kA interrupting · Noark Electric A25R3FH800
A25R3FH800
Available For Back-Order15445 – Loyalty RewardsAir Circuit Breaker · 800A · 2500A Frame, 4-Pole, Fixed Horizontal Connection, 85kA at 480VAC · Noark Electrical A25R4FH800
A25R4FH800
Available For Back-Order21623 – Loyalty RewardsAir Circuit Breaker · 600A, 4-Pole, 2500A Frame · Fixed Vertical Connection, 85kA at 480VAC · Noark Electrical A25R4FV600
A25R4FV600
Available For Back-Order20547 – Loyalty RewardsAir Circuit Breaker · 600A, 3-Pole, Fixed, Vertical Connection, 2500A Frame, 85kA @ 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25R3FV600
A25R3FV600
Available For Back-Order14677 – Loyalty RewardsAir Circuit Breaker · 600A, 2500A Frame, 4-Pole, Fixed Horizontal Connection, 85kA at 480VAC · Noark Electrical A25R4FH600
A25R4FH600
Available For Back-Order20547 – Loyalty RewardsAir Circuit Breaker · 600A, 2500A Frame, 4-Pole, Drawout, Horizontal Connection, 85kA at 480VAC · UL 1066 / CSA Certified · Noark Electrical A25R4DH600
A25R4DH600
Available For Back-Order22701 – Loyalty RewardsAir Circuit Breaker · 600A, 2500A Frame, 4-Pole · Drawout Vertical Connection · Noark Electrical A25R4DV600
A25R4DV600
Available For Back-Order22701 – Loyalty RewardsAir Circuit Breaker · 600A, 2500A Frame, 3-Pole, Drawout, Vertical Connection, 85kA at 480VAC · UL 1066/CSA Approved · Noark Electrical A25R3DV600
A25R3DV600
Available For Back-Order16215 – Loyalty RewardsAir Circuit Breaker · 600A, 2500A Frame, 3-Pole · Drawout, Horizontal Connection · Noark Electrical A25R3DH600
A25R3DH600
Available For Back-Order16215 – Loyalty RewardsAir Circuit Breaker · 600A · 3-Pole Fixed Horizontal Connection · 2500A Frame 85kA at 480VAC · Noark Electrical A25R3FH600
A25R3FH600
Available For Back-Order14677 – Loyalty RewardsAir Circuit Breaker · 2500A, 4-Pole, 85kA at 480VAC · Fixed Vertical Connection · Noark Electrical A25R4FV2500
A25R4FV2500
Available For Back-Order26259 – Loyalty RewardsAir Circuit Breaker · 2500A 3-Pole 85kA at 480VAC · Fixed Type Vertical Connection · Noark Electrical A25R3FV2500
A25R3FV2500
Available For Back-Order18756 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 4-Pole, Fixed Vertical Connection, 85kA at 480VAC · Noark Electrical A25R4FV2000
A25R4FV2000
Available For Back-Order25017 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 4-Pole, Drawout, Horizontal Connection, 85kA @ 480V AC · UL 1066 Power Circuit Breaker · Noark Electrical A25R4DH2000
A25R4DH2000
Available For Back-Order27652 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 3-Pole, Fixed Vertical Connection, 85kA at 480V AC · UL 1066 Power Distribution · Noark Electrical A25R3FV2000
A25R3FV2000
Available For Back-Order17869 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 3-Pole, Fixed Horizontal, 85kA at 480VAC · Noark Electrical A25R3FH2000
A25R3FH2000
Available For Back-Order17869 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 3-Pole, Drawout, Vertical Connection, 85kA @ 480VAC · UL 1066 / CSA Approved · Noark Electric A25R3DV2000
A25R3DV2000
Available For Back-Order19751 – Loyalty RewardsAir Circuit Breaker · 2000A rated current, 2500A frame, 4-pole, fixed horizontal connection, 85kA at 480VAC · UL 1066 power circuit breaker · Noark Electrical A25R4FH2000
A25R4FH2000
Available For Back-Order25017 – Loyalty RewardsAir Circuit Breaker · 2000A Rating, 2500A Frame, 3-Pole, Drawout, Horizontal Connection, 85kA @ 480VAC · UL 1066 / CSA Approved · Noark Electrical A25R3DH2000
A25R3DH2000
Available For Back-Order19751 – Loyalty RewardsAir Circuit Breaker · 2000A Rated Current, 2500A Frame, 4-Pole, Drawout, Rear Vertical Connection, 85kA at 480V AC · UL 1066 / CSA C22.2 No. 31 · Noark Electrical A25R4DV2000
A25R4DV2000
Available For Back-Order27652 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Fixed Mount, 85kA Interrupting Rating, Horizontal Connection · Noark Electrical A25R3FH1600
A25R3FH1600
Available For Back-Order17027 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Drawout, 85kA @ 480VAC · Horizontal Connection · Noark Electrical A25R3DH1600
A25R3DH1600
Available For Back-Order18812 – Loyalty RewardsAir Circuit Breaker · 1600A, 2500A Frame, 4-Pole, Fixed, Vertical Connection, 85kA at 480VAC · Noark Electrical A25R4FV1600
A25R4FV1600
Available For Back-Order23838 – Loyalty RewardsAir Circuit Breaker · 1600A, 2500A Frame, 4-Pole, Fixed Horizontal Connection, 85kA at 480VAC · UL 1066 / CSA Approved · Noark Electrical A25R4FH1600
A25R4FH1600
Available For Back-Order23838 – Loyalty RewardsAir Circuit Breaker · 1600A, 2500A Frame, 4-Pole, Drawout, Vertical Connection, 85kA @ 480VAC · Noark Electrical A25R4DV1600
A25R4DV1600
Available For Back-Order26337 – Loyalty RewardsAir Circuit Breaker · 1600A, 2500A Frame, 4-Pole, Drawout, Horizontal Connection, 85kA @ 480VAC · UL 1066/CSA for switchgear · Noark Electrical A25R4DH1600
A25R4DH1600
Available For Back-Order26337 – Loyalty RewardsAir Circuit Breaker · 1600A, 2500A Frame, 3-Pole, Fixed, Vertical Connection, 85kA @ 480V AC · UL 1066 Power Distribution Breaker · Noark Electrical A25R3FV1600
A25R3FV1600
Available For Back-Order17027 – Loyalty RewardsAir Circuit Breaker · 1600A · 2500A Frame, 3-Pole, Drawout, Vertical Connection, 85kA at 480VAC · Noark Electrical A25R3DV1600
A25R3DV1600
Available For Back-Order18812 – Loyalty RewardsAir Circuit Breaker · 1200A, 4-Pole, 2500A Frame, Drawout Vertical Connection, 85kA at 480VAC · Noark Electrical A25R4DV1200
A25R4DV1200
Available For Back-Order25077 – Loyalty RewardsAir Circuit Breaker · 1200A, 3-Pole, Fixed, Vertical Connection, 2500A Frame, 85kA @ 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25R3FV1200
A25R3FV1200
Available For Back-Order16214 – Loyalty RewardsAir Circuit Breaker · 1200A, 3-Pole, 85kA @ 480VAC · Fixed Mount, Horizontal Connection · Noark Electrical A25R3FH1200
A25R3FH1200
Available For Back-Order16214 – Loyalty RewardsAir Circuit Breaker · 1200A, 2500A Frame, 85kA at 480VAC, 3-Pole Drawout Horizontal · Noark Electrical A25R3DH1200
A25R3DH1200
Available For Back-Order17912 – Loyalty RewardsAir Circuit Breaker · 1200A, 2500A Frame, 4-Pole, Fixed, Horizontal Connection, 85kA @ 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25R4FH1200
A25R4FH1200
Available For Back-Order22699 – Loyalty RewardsAir Circuit Breaker · 1200A, 2500A Frame, 4-Pole, Fixed Vertical Mount, 85kA at 480VAC · UL 1066 / CSA C22.2 No.31 · Noark Electrical A25R4FV1200
A25R4FV1200
Available For Back-Order22699 – Loyalty RewardsAir Circuit Breaker · 1200A, 2500A Frame, 4-Pole, Drawout, Horizontal Connection, 85kA @ 480VAC · UL 1066 / CSA Approved · Noark Electrical A25R4DH1200
A25R4DH1200
Available For Back-Order25077 – Loyalty RewardsAir Circuit Breaker · 1200A, 2500A Frame, 3-Pole, Drawout, Vertical Connection, 85kA at 480VAC · UL 1066 / CSA Approved · Noark Electrical A25R3DV1200
A25R3DV1200
Available For Back-Order17912 – Loyalty Rewards
Quick Decision Summary
- Choose 85kA@480VAC air circuit breakers where available fault current and coordination targets require a high interrupting rating at 480V systems.
- For 600A through 2500A frames, confirm not only frame size but also sensor, trip setting range, poles, mounting style, and accessory requirements.
- Replacement work should start with the existing breaker family, drawout or fixed design, bus connection pattern, and trip unit functions before comparing price.
- Noark can be a practical option for many standard industrial and commercial applications, but installed base compatibility and engineering preference may favour Eaton, ABB, Schneider, or Siemens in some facilities.
- Interrupting rating, short-time withstand, selective coordination, and available fault current should be reviewed by qualified personnel before purchase or installation.
This category covers air circuit breakers in the 85kA at 480VAC class, typically used in larger switchboards, distribution sections, generator tie-ins, main service equipment, and major feeder positions. Buyers in this range are usually balancing fault duty, coordination, maintainability, and replacement fit. For most projects, the right choice is not just the highest amp frame. It is the breaker that matches the system fault level, trip strategy, physical arrangement, and service expectations of the site.
What Are 85kA@480VAC?
In this context, 85kA@480VAC refers to air circuit breakers with an interrupting capacity rated for up to 85,000 amps of fault current at 480VAC. These breakers are generally used above the moulded case range where higher continuous current, more adjustable protection, serviceability, and drawout construction are common requirements. In the 600A through 2500A frame range, they are often selected for mains, large feeders, tie breakers, and critical distribution points where fault levels are too high for lower-rated devices or where coordination and maintenance features matter.
Where Are 85kA@480VAC Used?
These breakers are commonly used in industrial plants, commercial towers, institutional buildings, data and telecom support infrastructure, water and wastewater facilities, manufacturing lines, and larger multi-tenant electrical rooms. Typical placements include service entrance sections, main distribution boards, generator paralleling gear, motor control distribution, and large subfeeds. They are especially relevant where utility transformers are close to the service, where generator contribution increases fault current, or where the design team needs a higher interrupting margin at 480V.
How To Choose 85kA@480VAC
Start with available fault current at the point of installation and verify the breaker interrupting rating is suitable for the system. Then confirm the continuous current requirement, frame size, and trip unit adjustment range. After that, review poles, neutral requirements, fixed or drawout construction, accessory needs such as shunt trip or undervoltage release, auxiliary contacts, communication modules, and any interlocking requirements. For replacement jobs, check dimensions, cradle style, bus stab arrangement, door cutout, and control wiring. For new work, also review short-time delay, instantaneous settings, ground fault functions where required by design, and coordination with downstream breakers. A lower-priced breaker that does not fit the section, accessory scheme, or coordination study usually costs more in the field.
Trade Rules Of Thumb
As a typical rule of thumb, high interrupting ACBs are most often justified at mains and large feeders where transformer size, low impedance, or generator contribution pushes fault current upward. Another practical rule is to treat replacement ACB work as a system job, not a single-part job. Nameplate amp rating alone is not enough. Electricians and maintenance teams usually verify frame, sensor, trip logic, accessory voltage, and mechanical fit before ordering. In selective coordination work, more adjustable trip units and short-time functions can be useful, but settings must come from the project design or study rather than guesswork. These are practical buying rules only, not code requirements.
Sizing Guidelines
For sizing, first determine the actual load current, duty cycle, ambient conditions, and future expansion allowance. Then select a frame and sensor combination that covers the required continuous current without forcing the trip settings to the edge of their range. In this category, common buying decisions involve whether a 600A, 800A, 1200A, 1600A, 2000A, or 2500A frame is the better fit for the switchboard section and protection scheme. Interrupting capacity must meet or exceed the available fault current at 480VAC. If the breaker is part of a coordinated system, short-time withstand and trip curve flexibility may matter as much as the amp rating. Final sizing and settings should be confirmed by the engineer of record or other qualified person using the applicable Canadian codes, equipment documentation, and study data.
Common Installation Practices
On new installations, common practice is to verify section dimensions, bus alignment, control power, and accessory operation before energization. On drawout units, technicians typically check racking operation, cell interlocks, secondary disconnect engagement, and position indication. On fixed-mounted units, bus terminations, torque values, phase spacing, and cable bending space are key checks. Functional testing often includes open and close operation, trip unit setup review, accessory verification, and where required, secondary injection or other commissioning procedures. Because these breakers are usually installed in critical distribution equipment, lockout, arc flash precautions, and manufacturer procedures are especially important.
Common Mistakes
One common mistake is assuming any 85kA breaker in the same amp range will interchange with an existing unit. In practice, cradle design, bus connection geometry, door hardware, and accessory wiring can differ significantly by family. Another mistake is focusing only on frame amperage while overlooking trip unit type, long-time and short-time adjustment range, or accessory voltage. Buyers also sometimes miss the difference between interrupting rating and coordination performance. In retrofit work, failing to confirm drawout cell compatibility can create expensive delays. In design work, selecting a breaker without checking available fault current, study assumptions, or downstream coordination can lead to rework.
Brand Comparisons
Noark is often considered where buyers want a practical alternative for standard commercial and industrial distribution projects, especially when value and current product availability are important. Eaton, ABB, Schneider, and Siemens have strong installed bases across Canada and are frequently preferred where an existing lineup already uses those platforms, where facility standards specify them, or where direct replacement familiarity matters to maintenance staff. Matching the installed brand can be the right choice when interchangeability, service history, training, or spare parts strategy is the priority. Noark may be a suitable option for many new applications or planned equipment packages where the design team is open to an alternative and the breaker family meets the project requirements. The right comparison is usually based on fit, trip features, accessory support, lead time, and service strategy rather than brand name alone.
Related Products
Related products often include breaker accessories such as shunt trips, undervoltage releases, auxiliary contacts, alarm contacts, motor operators, interlocks, communication modules, drawout cradles, and replacement trip units where supported by the breaker family. Buyers in this category may also need switchboard components, control power transformers, metering, surge protection, lugs and connectors, bus hardware, and labelling for maintenance and commissioning work. For replacement projects, it is also common to review the surrounding section hardware, door escutcheons, and control wiring components at the same time.
Frequently Asked Questions
What does 85kA@480VAC mean on an air circuit breaker?
It refers to the breaker interrupting capacity at 480VAC. In simple terms, it indicates the maximum fault current the breaker is rated to interrupt safely under its listing and test conditions.
Is a 2500A frame always set to trip at 2500A?
No. The frame size, sensor rating, and trip unit settings are not always the same thing. Many breakers have adjustable protection settings within the limits of the breaker and trip system.
Can I replace an existing Eaton, ABB, Schneider, or Siemens breaker with Noark just by matching amperage and kA rating?
Usually not without further checks. You also need to confirm physical fit, mounting or drawout compatibility, accessory scheme, control voltage, trip functions, and any project or facility approval requirements.
When is an 85kA breaker necessary instead of a lower interrupting rating?
It is typically necessary when the available fault current at the installation point exceeds the rating of lower-kA options or when the design requires additional margin. This should be confirmed from a fault study or other qualified engineering review.
Are these breakers mainly for mains, or can they be used on feeders too?
They can be used for either, depending on the system design. They are common on mains and tie breakers, but large feeders in high-fault-current systems may also require this class of breaker.
What should I verify before ordering a replacement air circuit breaker?
Verify the existing breaker family, frame size, poles, trip unit type, accessory list, control voltage, mounting style, drawout or fixed construction, and the physical dimensions of the section. Photos and nameplate details are often helpful.