Air Circuit Breaker · 800A, 3-Pole, Drawout, 65kA at 480VAC, Horizontal Connection · 2500A Frame · Noark Electrical A25Q3DH800
A25Q3DH800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA14913 – Loyalty RewardsAir Circuit Breaker · 1200A, 3-Pole, 65kA at 480VAC · Drawout with Horizontal Connections · Noark Electrical A25Q3DH1200
A25Q3DH1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA15652 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Drawout, 65kA @ 600VAC, Horizontal Connection · UL 1066 Power Circuit Breaker · Noark Electrical A25Q3DH1600
A25Q3DH1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA16435 – Loyalty RewardsAir Circuit Breaker · 2000A, 3-Pole, Drawout, 65kA @ 480VAC · Horizontal Connections · Noark Electrical A25Q3DH2000
A25Q3DH2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA17248 – Loyalty RewardsAir Circuit Breaker · 600A, 3-Pole, Drawout, Vertical Connection, 65kA @ 600VAC · UL 1066 / CSA C22.2 No. 31 · Noark Electrical A25Q3DV600
A25Q3DV600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA14159 – Loyalty RewardsAir Circuit Breaker · 800A, 3-Pole, Drawout, Vertical Connection, 65kA @ 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25Q3DV800
A25Q3DV800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA14913 – Loyalty RewardsAir Circuit Breaker · 1200A, 3-Pole, Drawout, Vertical Connection, 2500A Frame, 65kA at 480VAC · UL 1066 / CSA Approved · Noark Electrical A25Q3DV1200
A25Q3DV1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA15652 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Drawout, Vertical Connection, 2500A Frame · UL 1066 Power Circuit Breaker · Noark Electrical A25Q3DV1600
A25Q3DV1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA16435 – Loyalty RewardsAir Circuit Breaker · 2000A, 3-Pole, Drawout, Vertical Connection, 65kA at 480VAC · 2500A Frame · Noark Electrical A25Q3DV2000
A25Q3DV2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA17248 – Loyalty RewardsAir Circuit Breaker · 600A, 3-Pole, Fixed, Horizontal Connections, 2500A Frame, 65kA @ 600Vac · UL 1066 Power Circuit Breaker · Noark Electrical A25Q3FH600
A25Q3FH600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA12814 – Loyalty RewardsAir Circuit Breaker · 800A, 3-Pole, Fixed, Horizontal Connection, 65kA Interrupting · UL 1066 / CSA C22.2 No. 31 · Noark Electrical A25Q3FH800
A25Q3FH800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA13494 – Loyalty RewardsAir Circuit Breaker · 1200A, 3-Pole, Fixed, Horizontal Connection, 2500A Frame, 65kA at 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25Q3FH1200
A25Q3FH1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA14159 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Fixed, Horizontal Connection, 65kA @ 480VAC, 2500A Frame · UL 1066 / CSA for switchgear replacement · Noark Electrical A25Q3FH1600
A25Q3FH1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA14869 – Loyalty RewardsAir Circuit Breaker · 2000A, 3-Pole, Fixed Mount, Horizontal Connection, 65kA at 480VAC, 2500A Frame · UL 1066 Power Circuit Breaker · Noark Electrical A25Q3FH2000
A25Q3FH2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA15608 – Loyalty RewardsAir Circuit Breaker · 600A, 3-Pole, Fixed, Vertical Terminals, 65kA at 480VAC · 2500A Frame · Noark Electrical A25Q3FV600
A25Q3FV600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA12814 – Loyalty RewardsAir Circuit Breaker · 800A · 3-Pole Fixed Vertical Connection · Noark Electrical A25Q3FV800
A25Q3FV800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA13494 – Loyalty RewardsAir Circuit Breaker · 1200A, 3-Pole, Fixed Mount, Vertical Rear Connection, 65kA @ 480VAC · 2500A Frame · Noark Electrical A25Q3FV1200
A25Q3FV1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA14159 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Fixed, Vertical Connection, 65kA @ 480VAC, 2500A Frame · UL 1066/CSA Listed · Noark Electrical A25Q3FV1600
A25Q3FV1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA14869 – Loyalty RewardsAir Circuit Breaker · 2000A Rating, 2500A Frame, 3-Pole, Fixed Vertical Connection, 65kA at 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25Q3FV2000
A25Q3FV2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA15608 – Loyalty RewardsAir Circuit Breaker · 2500A, 3-Pole, Fixed, Vertical Connection, 65kA @ 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25Q3FV2500
A25Q3FV2500
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA17698 – Loyalty RewardsAir Circuit Breaker · 600A, 4-Pole, Drawout, 65kA at 480VAC · Horizontal Connection · Noark Electrical A25Q4DH600
A25Q4DH600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA19823 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, Drawout, 65kA at 480VAC, 2500A Frame · Horizontal Connection · Noark Electrical A25Q4DH800
A25Q4DH800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA20878 – Loyalty RewardsAir Circuit Breaker · 1200A, 4-Pole, Drawout, 65kA at 480VAC · Horizontal Terminals · Noark Electrical A25Q4DH1200
A25Q4DH1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA21913 – Loyalty RewardsAir Circuit Breaker · 1600A, 4-Pole, Drawout, 65kA at 480VAC · Horizontal Connections · Noark Electrical A25Q4DH1600
A25Q4DH1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA23010 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 4-Pole, Drawout, Horizontal Connection, 65kA @ 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25Q4DH2000
A25Q4DH2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA24148 – Loyalty RewardsAir Circuit Breaker · 600A, 4-Pole, Drawout, Vertical Connection, 65kA at 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25Q4DV600
A25Q4DV600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA19823 – Loyalty RewardsAir Circuit Breaker · 800A · 4-Pole Drawout with Vertical Terminals · Noark Electrical A25Q4DV800
A25Q4DV800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA20878 – Loyalty RewardsAir Circuit Breaker · 1200A, 4-Pole, Drawout, 65kA @ 480VAC, Vertical Connection · 2500A Frame · Noark Electrical A25Q4DV1200
A25Q4DV1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA21913 – Loyalty RewardsAir Circuit Breaker · 1600A, 2500A Frame, 4-Pole, Drawout, Vertical Connection, 65kA at 480VAC · UL 1066/CSA Power Distribution · Noark Electrical A25Q4DV1600
A25Q4DV1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA23010 – Loyalty RewardsAir Circuit Breaker · 2000A, 4-Pole, Drawout, 65kA at 480VAC · Vertical Connection · Noark Electrical A25Q4DV2000
A25Q4DV2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA24148 – Loyalty RewardsAir Circuit Breaker · 600A, 4-Pole, Fixed, Horizontal, 65kA Interrupting · UL 1066/CSA Power Distribution · Noark Electrical A25Q4FH600
A25Q4FH600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA17940 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, Fixed Mount, 65kA Interrupting · For Commercial and Industrial Distribution · Noark Electrical A25Q4FH800
A25Q4FH800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA18892 – Loyalty RewardsAir Circuit Breaker · 1200A, 4-Pole, Fixed, Horizontal Connection, 65kA Interrupting · UL 1066 and CSA C22.2 No. 31 Listed · Noark Electrical A25Q4FH1200
A25Q4FH1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA19823 – Loyalty RewardsAir Circuit Breaker · 1600A, 4-Pole, Fixed Mount, Horizontal Rear Connections, 65kA Interrupting Capacity · UL 1066 and CSA Certified · Noark Electric A25Q4FH1600
A25Q4FH1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA20816 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 4-Pole, Fixed, Horizontal Connection, 65kA at 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25Q4FH2000
A25Q4FH2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA21851 – Loyalty RewardsAir Circuit Breaker · 600A, 4-Pole, Fixed, Vertical Connection, 2500A Frame, 65kA @ 480VAC · UL 1066 / CSA Certified · Noark Electrical A25Q4FV600
A25Q4FV600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA17940 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, Fixed, Vertical Connection, 2500A Frame, 65kA Interrupting · UL 1066 Power Distribution Breaker · Noark Electrical A25Q4FV800
A25Q4FV800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA18892 – Loyalty RewardsAir Circuit Breaker · 1200A, 4-Pole, Fixed, Vertical Connection, 65kA at 480VAC · 2500A Frame, UL 1066/CSA · Noark Electrical A25Q4FV1200
A25Q4FV1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA19823 – Loyalty RewardsAir Circuit Breaker · 1600A, 4-Pole, Fixed, Vertical Connection, 65kA @ 480VAC · 2500A Frame · Noark Electrical A25Q4FV1600
A25Q4FV1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA20816 – Loyalty RewardsAir Circuit Breaker · 2000A · 4-Pole Fixed Vertical Connection · Noark Electrical A25Q4FV2000
A25Q4FV2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA21851 – Loyalty RewardsAir Circuit Breaker · 2500A, 4-Pole, Fixed, Vertical Connection, 65kA at 480VAC · UL 1066 / CSA for switchgear replacement · Noark Electrical A25Q4FV2500
A25Q4FV2500
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA22948 – Loyalty Rewards
Quick Decision Summary
- Choose 65kA@480VAC air circuit breakers where available fault current and coordination targets call for a 65 kA interrupting rating at 480 VAC.
- For this range, buyers usually confirm frame size, sensor or trip unit range, fixed or drawout construction, pole count, and accessory requirements before ordering.
- In 600A through 2500A frame applications, air circuit breakers are commonly used as main breakers, tie breakers, generator breakers, and large feeder breakers in low-voltage distribution equipment.
- Noark can be a practical option for many standard commercial and industrial applications, but retrofit, spec-driven, or installed-base projects may still favour Eaton, ABB, Schneider, or Siemens when matching existing gear matters.
- Interrupting rating, short-time withstand, selective coordination, and physical fit in the switchboard or switchgear lineup should all be verified against the equipment design and available fault study.
65kA@480VAC air circuit breakers in the 600A through 2500A frame range are selected for larger low-voltage power distribution systems where service size, feeder capacity, and fault duty exceed the practical range of smaller branch or moulded case devices. For Canadian commercial, institutional, utility support, and industrial projects, the buying decision is usually less about the breaker alone and more about interrupting capacity, trip functionality, coordination, mounting style, and compatibility with the equipment it will be installed into. This category is most relevant for buyers replacing or specifying low-voltage main and feeder protection where 480 VAC system duty requires a 65 kA rating.
What Are 65kA@480VAC?
In this category, 65kA@480VAC refers to air circuit breakers rated to interrupt up to 65,000 amps of prospective short-circuit current at 480 VAC, within the broader 600A through 2500A frame class. Air circuit breakers, often called ACBs, are low-voltage power breakers used in larger distribution assemblies where adjustable protection, maintainability, and coordination are important. Compared with smaller breakers, they typically offer more advanced trip settings, accessory options, status indication, and in many cases drawout construction for serviceability. The 65 kA rating is not a sizing number for normal load current. It is a fault-duty rating that must be suitable for the available short-circuit current at the point of installation.
Where Are 65kA@480VAC Used?
These breakers are commonly used in main distribution sections, switchboards, switchgear lineups, generator paralleling gear, large MCC feeds, and major feeder positions in commercial and industrial facilities. Typical applications include manufacturing plants, data-support infrastructure, institutional buildings, water and wastewater facilities, large multi-tenant buildings, and facilities with substantial motor or transformer loads. A 65 kA at 480 VAC breaker is often chosen where the available fault current is too high for lower-rated devices, or where the engineer wants a stronger coordination and withstand platform than a smaller frame breaker can provide.
How To Choose 65kA@480VAC
Start with the system one-line and fault study. Confirm the breaker interrupting rating is adequate at the actual system voltage and installation point. Then confirm the continuous current requirement and choose the correct frame and sensor or rating plug range. After that, review the trip unit functions needed, such as long-time, short-time, instantaneous, and ground fault protection where applicable. Buyers should also verify fixed or drawout style, number of poles, terminal orientation, accessory needs, shunt trip, undervoltage release, auxiliary contacts, motor operator, and communication options. For replacement work, physical fit, bus connection geometry, cradle details, and control voltage are often as important as the amp rating. If the breaker is part of a coordinated system, do not choose on interrupting rating alone. Short-time delay capability and the trip curve shape can materially affect downstream selectivity.
Trade Rules Of Thumb
As a practical rule of thumb, main and tie breaker selections in this class should always be checked against a current fault calculation rather than estimated from service size alone. Another common trade rule is to leave room for future load growth and accessory needs, especially on mains and generator breakers, because replacing a large ACB later can be more disruptive than upsizing during the original build. For coordination, many designers prefer an ACB platform when they need adjustable short-time delay and better discrimination with downstream breakers. For retrofit jobs, matching the existing gear family is often the lowest-risk path when the original switchgear was built around a specific breaker envelope and cradle system. These are typical buying practices, not code rules, and final selection should follow the equipment design, manufacturer data, and the applicable Canadian electrical requirements.
Sizing Guidelines
Breaker sizing in this category has two separate parts: continuous current sizing and fault-duty verification. For continuous current, the breaker frame and trip settings must suit the calculated load, conductor ampacity, equipment rating, ambient assumptions, and any continuous-load treatment required by the design. For fault duty, the 65 kA at 480 VAC interrupting rating must meet or exceed the available short-circuit current at the line terminals. In many projects, engineers also review short-time withstand and coordination performance, not just the interrupting number. As an approximate buying guide, 600A to 1200A frames are often seen on larger feeders and smaller mains, while 1600A to 2500A frames are more common on service mains, ties, and major distribution sections. Exact sizing must be based on the one-line, load calculations, and the equipment manufacturer's ratings. Do not use a rule of thumb in place of a fault study or engineered coordination review.
Common Installation Practices
Common installation practice is to verify the breaker catalog number against the switchboard or switchgear bill of material before the equipment is energized. Installers typically confirm pole count, trip unit type, rating plug or sensor setting, control voltage, accessory wiring, and mechanical interlocks before insertion or bolting. On drawout units, checking cradle alignment, racking operation, secondary disconnect engagement, and position indication is standard practice. On fixed-mounted units, torque values, bus connection cleanliness, and phase spacing are critical. Functional testing often includes open and close operation, accessory checks, and trip unit setup review. Commissioning should be carried out by qualified personnel using the manufacturer's instructions and the project test procedure. Large power breakers can store significant mechanical and electrical energy, so lockout, arc-flash planning, and proper PPE remain essential.
Common Mistakes
One common mistake is assuming 65 kA at 480 VAC is automatically acceptable at every installation point in a 480 V system without checking the actual available fault current. Another is ordering by amp rating only and overlooking drawout versus fixed construction, trip unit functions, accessory voltage, or mounting compatibility. Buyers also run into trouble when replacing an existing breaker and assuming another brand will be a direct drop-in. In many cases it will not be. Coordination problems can also arise when a breaker with the right interrupting rating lacks the short-time or ground-fault features needed by the design. On retrofit work, missing details such as cradle type, terminal arrangement, or communication module requirements can delay startup. For generator and emergency systems, failing to verify control logic and shunt or undervoltage functions can create commissioning issues.
Brand Comparisons
Noark is commonly considered by buyers looking for a practical alternative in standard low-voltage distribution applications, especially where a new build or non-proprietary specification allows flexibility. It may be a sensible choice when the priority is obtaining a modern ACB platform with the required ratings and accessories without being locked into a legacy installed base. Eaton, ABB, Schneider, and Siemens remain heavily represented in existing Canadian commercial and industrial equipment, so they are often preferred where the project involves matching an installed lineup, maintaining standardisation across a facility, or satisfying an engineer's basis-of-design specification. None of these brands should be treated as universally interchangeable. The right choice depends on fit in the gear, support expectations, trip unit familiarity, accessory ecosystem, and whether the job is a new assembly, engineered retrofit, or direct replacement. If the existing switchgear was built around one of the major legacy platforms, staying with that family may reduce field risk. If the project is a fresh build and the specification allows alternatives, Noark may be cross-shopped as a value-oriented option for many standard applications.
Related Products
Buyers shopping this category often also review trip units, rating plugs, auxiliary contacts, shunt trips, undervoltage releases, motor operators, interlocks, drawout cradles, breaker position switches, and communication modules. At the equipment level, related products may include switchboards, switchgear sections, busway feeds, metering packages, surge protection, control power transformers, and downstream feeder breakers. For replacement projects, it is also common to confirm compatible lugs, terminal kits, door escutcheons, and retrofit mounting hardware before placing the order.
Frequently Asked Questions
What does 65kA@480VAC mean on an air circuit breaker?
It refers to the breaker interrupting rating at 480 VAC. In practical terms, it means the breaker is rated to safely interrupt up to 65,000 amps of prospective short-circuit current under its listed conditions. It does not mean the breaker carries 65,000 amps in normal service.
Is a 65 kA breaker always enough for a 480 V system?
No. The available fault current at the installation point must be calculated or confirmed from the project study. Some systems are below 65 kA and some are above it. The breaker interrupting rating must meet or exceed the available fault current where it is installed.
Can I replace an Eaton, ABB, Schneider, or Siemens air circuit breaker with Noark?
Not by assumption. Even if current and interrupting ratings appear similar, physical fit, cradle design, bus connections, control wiring, trip functions, and certification details may differ. Replacement suitability should be confirmed against the equipment design and manufacturer information.
What is the difference between frame size and trip rating?
Frame size is the breaker's physical and thermal platform range, such as a 1600A or 2500A frame. The trip rating or sensor setting determines the actual protection level used within that frame. A larger frame does not automatically mean the breaker is set to its maximum current value.
When is a drawout air circuit breaker preferred over a fixed breaker?
Drawout construction is often preferred where maintainability, faster replacement, isolation positions, or testing convenience matter. Fixed breakers can still be suitable in some applications, but drawout designs are common in larger switchgear and critical distribution systems.
Do I need ground fault protection on a breaker in this category?
That depends on the system design, service arrangement, and applicable code and engineering requirements. Some mains and distribution points require or benefit from ground fault functions, while others do not. The trip unit should be selected to match the project protection scheme.