- Available to Order | Typically Arrives in 1 - 3 Weeks From California USA18638 – Loyalty Rewards
Air Circuit Breaker · 800A · 2500A Frame · 3-Pole Drawout Horizontal · Noark Electrical A25H3DH800
A25H3DH800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA19613 – Loyalty RewardsAir Circuit Breaker · 1200A, 3-Pole, 2500A Frame, Drawout, 100kA at 480VAC · Horizontal Connection · Noark Electrical A25H3DH1200
A25H3DH1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA20589 – Loyalty RewardsAir Circuit Breaker · 1600A, 2500A Frame, 3 Pole, Drawout, 100kA at 480VAC, Horizontal Connection · Noark Electrical A25H3DH1600
A25H3DH1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA21623 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 3-Pole, Drawout, Horizontal Connection, 100kA Interrupting · Noark Electrical A25H3DH2000
A25H3DH2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA22702 – Loyalty RewardsAir Circuit Breaker · 600A, 3 Pole, Drawout, 2500A Frame, 100kA @ 480VAC · UL 1066/CSA Power Distribution · Noark Electrical A25H3DV600
A25H3DV600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA18638 – Loyalty RewardsAir Circuit Breaker · 800A, 3 Pole, Drawout, 100kA at 480VAC, 2500A Frame · Rear Vertical Connection · Noark Electrical A25H3DV800
A25H3DV800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA19613 – Loyalty RewardsAir Circuit Breaker · 1200A, 3 Pole, Drawout, Vertical Connection, 2500A Frame, 100kA @ 480VAC · UL 1066/CSA Power Distribution · Noark Electric A25H3DV1200
A25H3DV1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA21623 – Loyalty RewardsAir Circuit Breaker · 1600A, 3 Pole, Drawout, Vertical Connection, 100kA @ 480VAC, 2500A Frame · Noark Electrical A25H3DV1600
A25H3DV1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA21623 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 3 Pole, Drawout, Vertical Connection, 100kA @ 480VAC · Noark Electrical A25H3DV2000
A25H3DV2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA22702 – Loyalty RewardsAir Circuit Breaker · 600A · 3 Pole Fixed Horizontal Connection · 2500A Frame 100kA at 480VAC · Noark Electrical A25H3FH600
A25H3FH600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA16864 – Loyalty RewardsAir Circuit Breaker · 800A, 3-Pole, 2500A Frame · Fixed Horizontal Connection, 100kA @ 600VAC · Noark Electrical A25H3FH800
A25H3FH800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA17751 – Loyalty RewardsAir Circuit Breaker · 1200A, 3 Pole, 2500A Frame, Fixed Horizontal · 100kA @ 480VAC · Noark Electrical A25H3FH1200
A25H3FH1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA18638 – Loyalty RewardsAir Circuit Breaker · 1600A, 3 Pole, 2500A Frame, Fixed Horizontal Connection, 100kA at 480VAC · Noark Electrical A25H3FH1600
A25H3FH1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA19569 – Loyalty RewardsAir Circuit Breaker · 2000A, 3 Pole, 2500A Frame · Fixed Horizontal Connection, 100kA @ 480VAC · Noark Electric A25H3FH2000
A25H3FH2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA20544 – Loyalty RewardsAir Circuit Breaker · 600A, 3 Pole, 2500A Frame, 100kA @ 480VAC, Fixed Vertical · UL 1066/CSA C22.2 No.31 · Noark Electrical A25H3FV600
A25H3FV600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA16864 – Loyalty RewardsAir Circuit Breaker · 800A, 3 Pole, 2500A Frame, Fixed Vertical Connection, 100kA at 480VAC · UL 1066 / CSA · Noark Electrical A25H3FV800
A25H3FV800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA17751 – Loyalty RewardsAir Circuit Breaker · 1200A, 3 Pole, 2500A Frame · Fixed Vertical Connection, 100kA @ 480VAC · Noark Electrical A25H3FV1200
A25H3FV1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA18638 – Loyalty RewardsAir Circuit Breaker · 1600A · 2500A Frame, 3-Pole, Fixed Vertical Connection, 100kA @ 480VAC · Noark Electrical A25H3FV1600
A25H3FV1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA19569 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 3-Pole, Fixed Vertical Connection, 100kA at 480VAC · UL 1066 / CSA Approved · Noark Electrical A25H3FV2000
A25H3FV2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA20544 – Loyalty RewardsAir Circuit Breaker · 2500A 3 Pole 100kA at 480VAC · Fixed Vertical Mounting · Noark Electrical A25H3FV2500
A25H3FV2500
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA21579 – Loyalty RewardsAir Circuit Breaker · 600A, 4-Pole, 2500A Frame, Drawout, 100kA at 480VAC · Horizontal Connection · Noark Electric A25H4DH600
A25H4DH600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA26093 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, 2500A Frame, Drawout, 100kA at 480VAC · Horizontal Connection · Noark Electrical A25H4DH800
A25H4DH800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA27459 – Loyalty RewardsAir Circuit Breaker · 1200A, 2500A Frame, 4-Pole, Drawout, 100kA @ 480VAC · UL 1066 Power Distribution · Noark Electrical A25H4DH1200
A25H4DH1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA28824 – Loyalty RewardsAir Circuit Breaker · 1600A, 2500A Frame, 4-Pole, Drawout, 100kA at 480VAC, Horizontal Connection · Noark Electrical A25H4DH1600
A25H4DH1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA30273 – Loyalty RewardsAir Circuit Breaker · 2000A, 4-Pole, Drawout, 2500A Frame, 100kA @ 480VAC, Horizontal Connection · Noark Electrical A25H4DH2000
A25H4DH2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA31783 – Loyalty RewardsAir Circuit Breaker · 600A, 4-Pole, Drawout, 100kA @ 480VAC, 2500A Frame · Vertical Connection · Noark Electric A25H4DV600
A25H4DV600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA26093 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, 2500A Frame, 100kA @ 480VAC · Drawout, Vertical Connection · Noark Electrical A25H4DV800
A25H4DV800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA27459 – Loyalty RewardsAir Circuit Breaker · 1200A, 2500A Frame, 4-Pole, Drawout, Vertical Connection, 100kA at 480VAC · Noark Electrical A25H4DV1200
A25H4DV1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA28824 – Loyalty RewardsAir Circuit Breaker · 1600A, 2500A Frame, 4-Pole, Drawout, Vertical Connection, 100kA @ 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25H4DV1600
A25H4DV1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA30273 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 4 Pole, Drawout, Vertical Connection, 100kA at 480VAC · UL 1066 Power Circuit Breaker · Noark Electrical A25H4DV2000
A25H4DV2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA31783 – Loyalty RewardsAir Circuit Breaker · 600A, 4-Pole, Fixed, Horizontal Connection, 2500A Frame · UL 1066 / CSA C22.2 No. 268 · Noark Electrical A25H4FH600
A25H4FH600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA23610 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, 2500A Frame, 100kA at 480VAC, Fixed Horizontal Connection · UL 1066/CSA Approved · Noark Electric A25H4FH800
A25H4FH800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA24851 – Loyalty RewardsAir Circuit Breaker · 1200A, 4-Pole, 2500A Frame, Fixed Horizontal · 100kA at 480VAC · Noark Electrical A25H4FH1200
A25H4FH1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA26093 – Loyalty RewardsAir Circuit Breaker · 1600A, 4 Pole, 2500A Frame, Fixed Horizontal · UL 1066/CSA · Noark Electrical A25H4FH1600
A25H4FH1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA27397 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 4 Pole, Fixed Horizontal Connection, 100kA at 480VAC · UL 1066/CSA Approved · Noark Electric A25H4FH2000
A25H4FH2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA28762 – Loyalty RewardsAir Circuit Breaker · 600A · 2500A Frame, 4-Pole, Fixed Vertical Connection, 100kA @ 480VAC · Noark Electrical A25H4FV600
A25H4FV600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA23610 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, 2500A Frame, Fixed Vertical Connection, 100kA @ 480VAC · UL 1066 / CSA Certified · Noark Electric A25H4FV800
A25H4FV800
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA24851 – Loyalty RewardsAir Circuit Breaker · 1200A · 4 Pole Fixed Vertical · 100kA at 480VAC · Noark Electrical A25H4FV1200
A25H4FV1200
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA26093 – Loyalty RewardsAir Circuit Breaker · 1600A, 2500A Frame, 4-Pole, Fixed Vertical Connection, 100kA at 480VAC · UL 1066/CSA · Noark Electrical A25H4FV1600
A25H4FV1600
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA27397 – Loyalty RewardsAir Circuit Breaker · 2000A, 2500A Frame, 4 Pole, Fixed Vertical · UL 1066/CSA Power Distribution · Noark Electrical A25H4FV2000
A25H4FV2000
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA28762 – Loyalty RewardsAir Circuit Breaker · 2500A, 4-Pole, Fixed Mount, Vertical Connection, 100kA at 480V · UL 1066/CSA C22.2 No. 31 · Noark Electrical A25H4FV2500
A25H4FV2500
Available to Order | Typically Arrives in 1 - 3 Weeks From California USA30211 – Loyalty Rewards
Quick Decision Summary
- 100kA@480VAC air circuit breakers are selected where available fault current is high and a standard lower interrupting rating may not be enough.
- In this range, buyers usually need to confirm frame size, sensor or trip setting range, fixed or drawout construction, pole count, and accessory requirements before ordering.
- For switchboards, main distribution, generators, large MCC lineups, and critical facility distribution, interrupting rating must be coordinated with the calculated or engineered fault level at the point of installation.
- Noark is a practical option for many standard low-voltage power distribution applications, but matching an existing Eaton, ABB, Schneider, or Siemens lineup may still be the right choice when retrofit fit, accessory commonality, or service familiarity matters.
- Breaker selection and settings should be reviewed against the applicable Canadian Electrical Code, equipment short-circuit ratings, and the project coordination study.
This category covers air circuit breakers rated 100kA at 480VAC within larger 600A through 2500A frame distribution applications. These breakers are typically used as mains, tie breakers, feeder breakers, or generator breakers where high available fault current and adjustable protection are both important. For most buyers, the interrupting rating is only one part of the decision. You also need to confirm the frame and sensor range, trip unit functions, mounting style, accessory package, and whether the breaker must coordinate with upstream and downstream protective devices. In Canadian commercial and industrial work, these products are commonly specified for service equipment, large panel and switchboard sections, process plants, institutional buildings, and facilities with substantial transformer capacity.
What Are 100kA@480VAC?
In this context, 100kA@480VAC refers to air circuit breakers with an interrupting capacity of 100,000 amperes at 480 volts AC. That rating indicates the maximum prospective short-circuit current the breaker can safely interrupt under its tested conditions. Air circuit breakers in the 600A to 2500A frame range are generally used in low-voltage power distribution where moulded case breakers may not provide the same combination of current range, adjustability, serviceability, and accessory options. Many are supplied with electronic trip units that allow long-time, short-time, instantaneous, and ground fault functions, depending on model and application.
Where Are 100kA@480VAC Used?
These breakers are commonly used in main switchboards, distribution sections, generator paralleling gear, large mechanical service distribution, industrial process power, institutional buildings, data-related infrastructure, and facilities with large transformers or utility services that can produce high available fault current. A 100kA interrupting rating is often considered where the service entrance or major distribution point is close to a transformer, where multiple sources can contribute fault current, or where future system expansion may push fault levels above lower-rated devices. They are also used where selective coordination and adjustable protection are important for uptime and fault isolation.
How To Choose 100kA@480VAC
Start with the system voltage and the calculated available fault current at the exact installation point. Then confirm the required continuous current rating, frame size, and trip sensor range. After that, review whether you need fixed or drawout construction, 3-pole or 4-pole configuration, and which trip functions are required for coordination and ground fault protection. Accessory needs can be just as important as the breaker itself. Common requirements include shunt trip, undervoltage release, auxiliary contacts, bell alarms, motor operators, interlocks, and communication modules. For replacement work, verify physical fit, bus connection style, cradle requirements, control voltage, and whether the existing gear manufacturer approves or supports the intended substitution. A high interrupting rating does not guarantee retrofit compatibility.
Trade Rules Of Thumb
As a typical rule of thumb, the closer a breaker is to a large transformer or service source, the more carefully the available fault current needs to be checked. Another practical rule is that mains and ties in larger gear often need more trip flexibility than standard feeders because coordination and nuisance trip avoidance matter more. In retrofit projects, if the installed switchboard was built around a specific breaker family, matching the original platform or using an engineered retrofit kit is often safer than assuming another 100kA breaker will drop in. For future-proofing, some buyers choose a higher interrupting rating than the present calculation requires, but that should still be reviewed against cost, lead time, and the actual system study. These are practical buying rules only, not code rules.
Sizing Guidelines
Breaker sizing starts with the load and the equipment design, but in this category the more critical sizing questions are usually frame size, sensor range, and protection settings rather than only the nameplate ampere value. A 600A through 2500A frame may cover several sensor or rating plug options depending on the breaker family. For mains and large feeders, confirm the continuous load, ambient assumptions, enclosure conditions, and whether 100 percent rated equipment is required by design. For protection, long-time pickup and delay, short-time pickup and delay, instantaneous pickup, and ground fault settings should be based on the coordination study and equipment protection objectives. Do not use generic setting values as a substitute for engineering review. Interrupting rating, withstand rating, and short-time performance should also be checked where the application depends on selective coordination or downstream fault clearing.
Common Installation Practices
Typical installation practice includes verifying bus alignment, line and load orientation, torque values, control wiring, accessory operation, and trip unit programming before energization. Drawout breakers are commonly used where maintenance isolation and faster replacement are important, while fixed-mounted breakers may be suitable where simplicity and lower installed cost are preferred. On larger projects, contractors usually confirm secondary disconnects, cradle interlocks, racking access, and door cutout compatibility early in the submittal stage. Commissioning often includes primary or secondary injection testing, trip function verification, and confirmation that the breaker settings match the approved coordination documents. Installation and testing should be completed by qualified personnel and in accordance with the equipment manufacturer instructions and project engineering documents.
Common Mistakes
One common mistake is treating 100kA@480VAC as the only specification that matters. Buyers sometimes overlook frame dimensions, mounting style, cradle requirements, accessory voltage, or communication compatibility. Another frequent issue is assuming a breaker with the same ampere rating can replace an existing unit from another manufacturer without mechanical or electrical changes. It is also easy to miss the difference between interrupting rating and coordination performance. A breaker may safely clear a fault but still not deliver the selective coordination expected in the design. On service and generator applications, incorrect trip settings can cause nuisance tripping or poor downstream protection. Finally, some projects fail because the available fault current was estimated too loosely instead of being confirmed from the latest utility and system data.
Brand Comparisons
Noark is often considered by buyers looking for a practical alternative in standard low-voltage distribution projects, especially where a new lineup or a non-proprietary specification allows flexibility. Eaton, ABB, Schneider, and Siemens remain widely recognized in large power distribution because of their installed base, engineering support, retrofit pathways, and familiarity among consultants and service teams. If a facility already uses one of those platforms, staying with the same family may simplify spare parts, training, maintenance procedures, and approvals. Noark may be a suitable choice when the application is a straightforward new installation and the required ratings, trip functions, and accessory options align with the project scope. The right choice depends less on brand reputation alone and more on fit with the gear, support expectations, and whether the project is new construction, expansion, or retrofit.
Related Products
Related products often include switchboard sections, breaker cradles, trip units, rating plugs where applicable, shunt trips, undervoltage releases, auxiliary and alarm contacts, motor operators, mechanical interlocks, door escutcheons, control power transformers, metering packages, and communication accessories. Buyers working on complete distribution assemblies may also need surge protection, feeder breakers, busway connections, panel instrumentation, and replacement parts for existing gear. If the breaker is being used in a generator or transfer application, review the associated control scheme and any required interlocking or signalling hardware before ordering.
Frequently Asked Questions
What does 100kA@480VAC actually mean on an air circuit breaker?
It means the breaker has been rated to interrupt up to 100,000 amperes of fault current at 480VAC under its tested conditions. It does not mean the breaker is automatically suitable for every 480V application. The full application still depends on system fault current, equipment ratings, and the manufacturer data.
Is a 100kA breaker always better than a lower-rated breaker?
Not always. A higher interrupting rating can provide margin where fault current is high, but it may also increase cost and narrow the list of compatible breaker families. The correct rating is the one that meets or exceeds the calculated available fault current and fits the equipment design.
Can I replace an Eaton, ABB, Schneider, or Siemens air circuit breaker with a Noark unit?
Sometimes, but not as a simple assumption. You need to verify mechanical fit, bus connection details, cradle or drawout compatibility, control wiring, accessory functions, approvals, and any engineered retrofit requirements. In many retrofit jobs, matching the installed platform is still the most practical route.
When is drawout construction worth choosing over fixed mounting?
Drawout construction is often preferred where maintenance access, testing, isolation, and faster replacement are important, such as critical facilities or larger switchboards. Fixed-mounted breakers can be a sound choice where the design is simpler and lower installed cost is a priority.
Do I need an electronic trip unit on a breaker in this range?
In many 600A to 2500A air circuit breaker applications, an electronic trip unit is standard or strongly preferred because it allows adjustable protection and better coordination. The exact trip functions required depend on the system design, the coordination study, and whether ground fault protection is needed.
How should breaker settings be selected?
Settings should be selected from the project coordination study, equipment protection requirements, and manufacturer guidance. Long-time, short-time, instantaneous, and ground fault functions should not be set by guesswork. Final settings should be reviewed by qualified personnel familiar with the system.