Air Circuit Breaker · 1600A, 3-Pole, Drawout, Horizontal Connection, 100kA at 480VAC, 3200A Frame · UL 1066 Power Distribution Breaker · Noark Electrical A32H3DH1600
A32H3DH1600
Available For Back-Order23336 – Loyalty RewardsAir Circuit Breaker · 2000A, 3200A Frame, 3-Pole, Drawout, 100kA at 480VAC, Horizontal Connection · Noark Electrical A32H3DH2000
A32H3DH2000
Available For Back-Order24424 – Loyalty RewardsAir Circuit Breaker · 2500A, 3-Pole, 100kA @ 600Vac, Drawout, Horizontal Connection · 3200A Frame · Noark Electrical A32H3DH2500
A32H3DH2500
Available For Back-Order25514 – Loyalty RewardsAir Circuit Breaker · 800A Rated Current, 3200A Frame, 100kA at 480VAC, 3-Pole, Drawout, Vertical Connection · UL 1066/CSA Listed · Noark Electrical A32H3DV800
A32H3DV800
Available For Back-Order22244 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Drawout, Vertical Connection, 100kA at 480VAC · 3200A Frame · Noark Electrical A32H3DV1600
A32H3DV1600
Available For Back-Order23336 – Loyalty RewardsAir Circuit Breaker · 2000A, 3-Pole, Drawout, 100kA at 600VAC, Vertical Connection, 3200A Frame · UL 1066/CSA Power Distribution · Noark Electric A32H3DV2000
A32H3DV2000
Available For Back-Order24424 – Loyalty RewardsAir Circuit Breaker · 2500A, 3200A Frame, 3-Pole, Drawout, Vertical Connection, 100kA at 480VAC · UL 1066 Power Distribution · Noark Electrical A32H3DV2500
A32H3DV2500
Available For Back-Order25514 – Loyalty RewardsAir Circuit Breaker · 3200A Frame, 3P, Drawout, 100kA at 480VAC, Vertical Connection · UL 1066/CSA Power Distribution · Noark Electrical A32H3DV3200
A32H3DV3200
Available For Back-Order26606 – Loyalty RewardsAir Circuit Breaker · 800A, 3-Pole, Fixed, Horizontal Connection, 100kA at 480VAC, 3200A Frame · UL 1066 Power Distribution · Noark Electric A32H3FH800
A32H3FH800
Available For Back-Order20264 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Fixed Horizontal, 100kA Interrupting · 3200A Frame · Noark Electric A32H3FH1600
A32H3FH1600
Available For Back-Order21355 – Loyalty RewardsAir Circuit Breaker · 2000A, 3-Pole, Fixed, Horizontal Connection, 100kA at 600VAC, 3200A Frame · UL 1066/CSA Power Distribution · Noark Electrical A32H3FH2000
A32H3FH2000
Available For Back-Order22197 – Loyalty RewardsAir Circuit Breaker · 2500A, 3200A Frame, 3-Pole, Fixed, Horizontal Connection, 100kA at 600VAC · UL 1066 Power Distribution Breaker · Noark Electric A32H3FH2500
A32H3FH2500
Available For Back-Order23289 – Loyalty RewardsAir Circuit Breaker · 800A, 3-Pole, 100kA at 480VAC · Fixed Mount, Vertical Connection · Noark Electrical A32H3FV800
A32H3FV800
Available For Back-Order20264 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Fixed, Vertical Connection, 100kA at 600 Vac, 3200A Frame · UL 1066/CSA Power Distribution · Noark Electrical A32H3FV1600
A32H3FV1600
Available For Back-Order21355 – Loyalty RewardsAir Circuit Breaker · 2000A Rated Current, 3200A Frame, 100kA at 600VAC, 3-Pole Fixed Vertical Connection · Noark Electrical A32H3FV2000
A32H3FV2000
Available For Back-Order22197 – Loyalty RewardsAir Circuit Breaker · 2500A, 3-Pole, 100kA at 480VAC · Fixed Type, Vertical Connection · Noark Electrical A32H3FV2500
A32H3FV2500
Available For Back-Order23289 – Loyalty RewardsAir Circuit Breaker · 3200A 3-Pole 100kA at 480VAC · Fixed Vertical Connection · Noark Electrical A32H3FV3200
A32H3FV3200
Available For Back-Order24132 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, Drawout, 100kA @ 480VAC · 3200A Frame with Horizontal Connections · Noark Electrical A32H4DH800
A32H4DH800
Available For Back-Order31141 – Loyalty RewardsAir Circuit Breaker · 1600A, 4-Pole, Drawout, 100kA at 480VAC, Horizontal Connection · 3200A Frame · Noark Electrical A32H4DH1600
A32H4DH1600
Available For Back-Order32668 – Loyalty RewardsAir Circuit Breaker · 2000A, 4-Pole, Drawout, 100kA at 480VAC, Horizontal Connection · 3200A Frame · Noark Electrical A32H4DH2000
A32H4DH2000
Available For Back-Order34195 – Loyalty RewardsAir Circuit Breaker · 2500A, 3200A Frame, 4-Pole, Drawout, 100kA at 480VAC, Horizontal Connection · UL 1066 Power Distribution Breaker · Noark Electrical A32H4DH2500
A32H4DH2500
Available For Back-Order35722 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, 100kA at 480/600VAC · Drawout, Vertical Connection, 3200A Frame · Noark Electrical A32H4DV800
A32H4DV800
Available For Back-Order31141 – Loyalty RewardsAir Circuit Breaker · 1600A, 4-Pole, 100kA at 480VAC · Drawout, Vertical Connection, 3200A Frame · Noark Electric A32H4DV1600
A32H4DV1600
Available For Back-Order32668 – Loyalty RewardsAir Circuit Breaker · 2000A, 100kA at 480VAC, 4-Pole · Drawout, Vertical Connection · Noark Electrical A32H4DV2000
A32H4DV2000
Available For Back-Order34195 – Loyalty RewardsAir Circuit Breaker · 2500A, 4-Pole, Drawout, 100kA at 480/600VAC, Vertical Connection · 3200A Frame · Noark Electrical A32H4DV2500
A32H4DV2500
Available For Back-Order35722 – Loyalty RewardsAir Circuit Breaker · 3200A Frame, 4-Pole, Drawout, 100kA at 480VAC, Vertical Connection · UL 1066/CSA Power Distribution Breaker · Noark Electrical A32H4DV3200
A32H4DV3200
Available For Back-Order37248 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, Fixed Mount, Horizontal Connections, 100kA at 600VAC, 3200A Frame · UL 1066/CSA Listed · Noark Electrical A32H4FH800
A32H4FH800
Available For Back-Order28370 – Loyalty RewardsAir Circuit Breaker · 1600A, 4-Pole, Fixed Mount, Horizontal Connections, 100kA Interrupting Capacity · 3200A Frame · Noark Electric A32H4FH1600
A32H4FH1600
Available For Back-Order29897 – Loyalty RewardsAir Circuit Breaker · 2000A, 4-Pole, 100kA at 480VAC · Fixed Horizontal Connection · Noark Electric A32H4FH2000
A32H4FH2000
Available For Back-Order31078 – Loyalty RewardsAir Circuit Breaker · 2500A, 4-Pole, Fixed, Horizontal Connection, 100kA at 480VAC · 3200A Frame · Noark Electrical A32H4FH2500
A32H4FH2500
Available For Back-Order32606 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, 100kA at 480VAC · Fixed Mount, Vertical Connection, 3200A Frame · Noark Electrical A32H4FV800
A32H4FV800
Available For Back-Order28370 – Loyalty RewardsAir Circuit Breaker · 1600A, 4-Pole, 100kA at 600V AC, Fixed Vertical Connection, 3200A Frame · UL 1066 / CSA C22.2 No. 31 · Noark Electric A32H4FV1600
A32H4FV1600
Available For Back-Order29897 – Loyalty RewardsAir Circuit Breaker · 2000A, 4-Pole, Fixed Mount, Vertical Terminals, 100kA @ 635V AC, 3200A Frame · UL 1066/CSA Power Distribution · Noark Electrical A32H4FV2000
A32H4FV2000
Available For Back-Order31078 – Loyalty RewardsAir Circuit Breaker · 2500A, 3200A Frame, 4-Pole, Fixed, Vertical Connection, 100kA at 600VAC · UL 1066/CSA · Noark Electrical A32H4FV2500
A32H4FV2500
Available For Back-Order32606 – Loyalty RewardsAir Circuit Breaker · 3200A 4-Pole 100kA at 480VAC · Fixed Vertical Connection · Noark Electrical A32H4FV3200
A32H4FV3200
Available For Back-Order33787 – Loyalty RewardsAir Circuit Breaker · 800A, 3-Pole, Drawout, 65kA at 480VAC, Horizontal Connection · 3200A Frame · Noark Electrical A32Q3DH800
A32Q3DH800
Available For Back-Order16819 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Drawout, 65kA @ 600VAC, Horizontal Connection · 3200A Frame · Noark Electrical A32Q3DH1600
A32Q3DH1600
Available For Back-Order17644 – Loyalty RewardsAir Circuit Breaker · 2000A, 3200A Frame, 3-Pole, Drawout, Horizontal Connection, 65kA at 600VAC · UL 1066/CSA Power Circuit Breaker · Noark Electric A32Q3DH2000
A32Q3DH2000
Available For Back-Order18468 – Loyalty RewardsAir Circuit Breaker · 2500A, 3200A Frame, 65kA at 600VAC, 3-Pole, Drawout, Horizontal · UL 1066 Power Circuit Breaker · Noark Electrical A32Q3DH2500
A32Q3DH2500
Available For Back-Order19293 – Loyalty RewardsAir Circuit Breaker · 800A, 3-Pole, 65kA @ 480VAC · Drawout, Vertical Connection, 3200A Frame · Noark Electrical A32Q3DV800
A32Q3DV800
Available For Back-Order16819 – Loyalty RewardsAir Circuit Breaker · 1600A, 3200A Frame, 65kA at 480VAC, 3-Pole, Drawout, Vertical Connection · UL 1066 Power Distribution Breaker · Noark Electrical A32Q3DV1600
A32Q3DV1600
Available For Back-Order17644 – Loyalty RewardsAir Circuit Breaker · 2000A Rated Current, 3200A Frame, 65kA at 480VAC, 3-Pole Drawout, Vertical Connection · UL 1066 Power Distribution Breaker · Noark Electrical A32Q3DV2000
A32Q3DV2000
Available For Back-Order18468 – Loyalty RewardsAir Circuit Breaker · 2500A, 3200A Frame, 65kA at 600VAC, 3-Pole, Drawout, Vertical Connection · UL 1066 Power Circuit Breaker · Noark Electrical A32Q3DV2500
A32Q3DV2500
Available For Back-Order19293 – Loyalty RewardsAir Circuit Breaker · 3200A, 3-Pole, Drawout, 65kA Interrupting · Vertical Connection · Noark Electrical A32Q3DV3200
A32Q3DV3200
Available For Back-Order20119 – Loyalty RewardsAir Circuit Breaker · 800A, 3-Pole, 3200A Frame, 65kA at 600VAC · Fixed Horizontal Connection · Noark Electric A32Q3FH800
A32Q3FH800
Available For Back-Order14840 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, 65kA at 480VAC · Fixed Horizontal Connection, 3200A Frame · Noark Electric A32Q3FH1600
A32Q3FH1600
Available For Back-Order15666 – Loyalty RewardsAir Circuit Breaker · 2000A Rated Current, 3200A Frame, 65kA at 600VAC, 3-Pole, Fixed Horizontal · UL 1066 / CSA Certified · Noark Electrical A32Q3FH2000
A32Q3FH2000
Available For Back-Order16242 – Loyalty RewardsAir Circuit Breaker · 2500A, 3-Pole, 65kA at 600VAC · Fixed Horizontal Connection · Noark Electrical A32Q3FH2500
A32Q3FH2500
Available For Back-Order17065 – Loyalty RewardsAir Circuit Breaker · 800A, 3-Pole, 65kA at 480VAC · Fixed Vertical Connection · Noark Electrical A32Q3FV800
A32Q3FV800
Available For Back-Order14840 – Loyalty RewardsAir Circuit Breaker · 1600A, 3-Pole, Fixed, Vertical Connection, 65kA at 480VAC · 3200A Frame · Noark Electrical A32Q3FV1600
A32Q3FV1600
Available For Back-Order15666 – Loyalty RewardsAir Circuit Breaker · 2000A Trip on 3200A Frame, 65kA at 600VAC, 3-Pole, Fixed Vertical Connection · UL 1066 Power Distribution Breaker · Noark Electrical A32Q3FV2000
A32Q3FV2000
Available For Back-Order16242 – Loyalty RewardsAir Circuit Breaker · 2500A, 3-Pole, Fixed Mount, 65kA at 480VAC, Vertical Connections · UL 1066 Power Distribution Breaker · Noark Electrical A32Q3FV2500
A32Q3FV2500
Available For Back-Order17065 – Loyalty RewardsAir Circuit Breaker · 3200A, 3P, 65kA at 600VAC, Fixed Vertical Connection · UL 1066/CSA C22.2 No. 31 · Noark Electrical A32Q3FV3200
A32Q3FV3200
Available For Back-Order17645 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, 65kA at 480VAC · Drawout, Horizontal Connection · Noark Electrical A32Q4DH800
A32Q4DH800
Available For Back-Order23548 – Loyalty RewardsAir Circuit Breaker · 1600A Rated Current, 3200A Frame, 4-Pole, Drawout, 65kA at 480VAC, Horizontal Connection · Noark Electrical A32Q4DH1600
A32Q4DH1600
Available For Back-Order24702 – Loyalty RewardsAir Circuit Breaker · 2000A, 3200A Frame, 65kA at 480VAC, 4-Pole, Drawout, Horizontal Connection · UL 1066/CSA Power Distribution · Noark Electrical A32Q4DH2000
A32Q4DH2000
Available For Back-Order25857 – Loyalty RewardsAir Circuit Breaker · 2500A, 3200A Frame, 65kA at 480VAC, 4-Pole, Drawout, Horizontal Connection · UL 1066/CSA Approved · Noark Electrical A32Q4DH2500
A32Q4DH2500
Available For Back-Order27011 – Loyalty RewardsAir Circuit Breaker · 800A, 4-Pole, Drawout, 65kA at 480VAC, 3200A Frame, Vertical Connection · UL 1066/CSA Power Distribution · Noark Electrical A32Q4DV800
A32Q4DV800
Available For Back-Order23548 – Loyalty RewardsAir Circuit Breaker · 1600A, 4-Pole, Drawout, 65kA at 480V AC, Vertical Connection · 3200A Frame · Noark Electrical A32Q4DV1600
A32Q4DV1600
Available For Back-Order24702 – Loyalty Rewards
Quick Decision Summary
- 800A through 3200A frame air circuit breakers are typically used as mains, tie breakers, large feeder breakers, and generator or distribution breakers in low-voltage switchgear.
- Do not choose by amp rating alone. Confirm frame size, sensor or trip range, interrupting rating, poles, mounting style, accessory requirements, and retrofit constraints.
- For replacement work, the installed switchgear lineup often matters as much as the breaker nameplate. Physical fit, bus connection geometry, cradle style, and control wiring can decide whether a breaker is a practical option.
- Noark can be a practical choice for many standard applications, but matching Eaton, ABB, Schneider, or Siemens may still be the right move where installed infrastructure, approvals, or maintenance standardisation drive the project.
- Trip unit settings, coordination, and short-circuit performance should be reviewed by qualified personnel and verified against the equipment documentation and applicable Canadian code requirements.
800A through 3200A frame air circuit breakers sit in the heavy end of low-voltage power distribution. These breakers are commonly specified for service entrances, main distribution sections, generator paralleling gear, large MCC feeds, and critical facility switchboards where high continuous current, selective coordination, and maintainability matter. For buyers and contractors, the main challenge is not simply finding a breaker with the right amp number. The real job is matching frame, trip capability, fault duty, accessory package, and mechanical compatibility to the switchgear and the operating philosophy of the site.
What Are 800A Through 3200A Frame?
In this category, the frame refers to the physical breaker platform and its maximum design envelope, not necessarily the exact continuous current setting in service. An air circuit breaker, or ACB, uses air as the insulating and arc-extinguishing medium and is generally built for low-voltage distribution systems where larger current ratings, adjustable protection, and serviceable accessories are required. Within an 800A through 3200A frame range, the same breaker family may support different sensor ratings, trip unit options, and accessory combinations. That is why a 1600A frame breaker, for example, may be supplied with a lower long-time pickup setting depending on the application. For purchasing, frame size helps narrow the mechanical platform, but the final selection still depends on the trip unit, interrupting rating, poles, and installation details.
Where Are 800A Through 3200A Frame Used?
These breakers are commonly used in commercial towers, institutional buildings, industrial plants, data centres, healthcare facilities, water and wastewater sites, and large multi-tenant distribution systems. Typical placements include service mains, main-tie-main arrangements, generator breakers, capacitor bank protection, large mechanical distribution sections, and high-capacity feeder positions. They are also common in retrofit projects where an aging low-voltage power breaker must be replaced to restore reliability, improve protection adjustability, or support maintenance planning. In facilities with critical uptime requirements, buyers often prefer ACB platforms because accessories such as shunt trips, undervoltage releases, motor operators, auxiliary contacts, and communication modules can be integrated into a coordinated protection scheme.
How To Choose 800A Through 3200A Frame
Start with the electrical basics: system voltage, continuous load, available fault current, required interrupting rating, and whether the breaker serves as a main, tie, or feeder. Then confirm the protection functions needed, such as long-time, short-time, instantaneous, and ground fault. After that, review the mechanical side carefully. For drawout applications, verify cradle compatibility, primary disconnect arrangement, secondary disconnects, cell dimensions, and shutter or interlock requirements. For fixed-mounted applications, check bus landing orientation, terminal spacing, and enclosure constraints. Also confirm the number of poles, neutral requirements, control voltage for accessories, and whether remote operation or communications are needed. In retrofit work, photos, nameplates, switchgear drawings, and field measurements can save major delays. A breaker that is electrically suitable but mechanically incompatible can turn a simple replacement into a custom project.
Trade Rules Of Thumb
As a typical rule of thumb, do not size a main or feeder breaker exactly at the expected continuous operating current. Leave practical headroom for real operating conditions, ambient effects, future load growth, and coordination adjustments where the design allows. For larger distribution systems, selective coordination usually becomes more important as the cost of nuisance tripping rises. Another practical rule is that replacement ACB projects should be treated as switchgear projects, not just breaker purchases. Field crews usually need to confirm more than amp rating and frame label. They should verify cell style, bus stabs, control plug arrangement, interlocks, and trip unit functionality. Where generator systems or high inrush loads are involved, short-time and instantaneous settings need special attention because a breaker that looks correct on paper may still trip poorly in service. These are practical guidelines only and must not replace engineering review, manufacturer data, or applicable code requirements.
Sizing Guidelines
For buying purposes, separate frame size from trip setting. The frame establishes the breaker platform range, while the trip unit and sensor determine how the breaker is actually set up for the load. Confirm the continuous current requirement first, then verify that the selected breaker and trip unit can be adjusted appropriately within that frame family. Next, check the available short-circuit current at the point of installation and make sure the breaker interrupting rating is suitable for the system. If ground fault protection is required, confirm that the trip unit supports it and that the scheme aligns with the rest of the distribution system. In main-tie-main and generator applications, review time-current coordination across upstream and downstream devices rather than selecting each breaker in isolation. For service entrance and critical distribution work, final sizing and settings should be based on project drawings, short-circuit and coordination studies, and the equipment manufacturer documentation.
Common Installation Practices
On new work, installers typically verify breaker condition, accessory operation, trip unit programming, and mechanical racking before energisation. Drawout breakers are commonly checked for smooth insertion, test position operation, connected position engagement, and proper secondary disconnect alignment. Control wiring for shunt trip, closing coils, motor charging, and auxiliary contacts should be identified and tested against the schematic, not assumed from colour alone. On retrofit jobs, crews often document the existing breaker cell, bus arrangement, and door interlock details before ordering. It is also common practice to inspect for heat damage, worn shutters, loose secondary contacts, and evidence of prior field modification in the switchgear compartment. Commissioning should include functional testing appropriate to the project scope and site procedures. Installation and energisation should be carried out by qualified personnel following lockout, arc flash, and manufacturer safety procedures.
Common Mistakes
One common mistake is assuming that a breaker with the same amp rating is automatically a suitable replacement. In this size range, physical compatibility and accessory matching are often the real problem. Another mistake is confusing frame rating with actual trip setting, which can lead to overbuying or misapplying the breaker. Buyers also sometimes overlook control voltage for accessories such as shunt trips, motor operators, and undervoltage releases. In retrofit work, failing to confirm drawout cell details, interlocks, and secondary disconnects can delay a shutdown window. On the protection side, a frequent issue is ordering a breaker without fully reviewing coordination and ground fault requirements, especially where the breaker is part of a selective system or generator-backed distribution. Finally, some projects focus only on the breaker and ignore the condition of the surrounding switchgear, even though worn compartments, damaged bus insulation, or obsolete controls may be the larger reliability risk.
Brand Comparisons
Noark is commonly considered where buyers want a current production alternative for standard low-voltage power distribution applications and want to evaluate value alongside feature set. Eaton, ABB, Schneider, and Siemens remain major reference brands in many installed bases, especially where the site already standardises on one platform, spare parts are stocked around that brand, or consultants have written around a familiar family of breakers. In those cases, matching the installed brand may be the most practical path for maintenance consistency, retrofit simplicity, and documentation continuity. Noark may be a sensible option when the project is new construction, a planned standardisation change, or a straightforward application where the available breaker family meets the electrical and mechanical requirements. The right choice depends less on brand reputation alone and more on fit with the switchgear, support expectations, accessory needs, and the owner's maintenance strategy. For many buyers, the most useful comparison is not which brand is universally better, but which one is the better fit for this specific lineup and operating environment.
Related Products
Projects involving 800A through 3200A frame air circuit breakers often also require breaker accessories, shunt trips, undervoltage releases, auxiliary contacts, motor operators, closing coils, trip signalling components, control power transformers, metering, and switchgear replacement parts. Depending on the job, buyers may also need lugs, bus connection hardware, door interlock components, racking tools, test kits, and protective relays or monitoring devices. For retrofit and maintenance work, it is also common to review related switchgear items such as compartment hardware, shutters, secondary disconnect assemblies, and control wiring components so the breaker replacement does not stall on a small missing part.
Frequently Asked Questions
What does frame size mean on an air circuit breaker?
Frame size refers to the breaker platform and its maximum design range, not always the exact current setting in service. The actual application depends on the trip unit, sensor rating, and adjustment range supplied with that breaker.
Can I replace an existing Eaton, ABB, Schneider, or Siemens breaker with Noark?
Sometimes, but it is not automatic. You need to confirm electrical suitability, physical fit, accessory compatibility, and any retrofit requirements in the existing switchgear. In many replacement jobs, matching the installed platform is still the simplest path.
Are 800A through 3200A frame breakers usually drawout or fixed?
Many breakers in this range are used in drawout switchgear, but fixed-mounted versions also exist. The correct choice depends on the equipment design, maintenance approach, and whether the project is new construction, replacement, or retrofit.
What information should I gather before ordering a replacement ACB?
Collect the breaker nameplate data, trip unit details, voltage, poles, interrupting rating, accessory list, control voltage, switchgear model information, and clear photos of the breaker and compartment. Field dimensions and bus connection details are also very helpful.
Do I need a coordination study when changing a large air circuit breaker?
In many larger systems, yes, or at minimum a review of the existing protection scheme. Changing trip units or settings without checking upstream and downstream devices can affect selective coordination, generator performance, and fault clearing behaviour.
Can I size the breaker only from the connected load?
No. Connected load is only part of the picture. You also need to consider continuous loading, available fault current, equipment ratings, protection functions, and the operating role of the breaker in the distribution system. Final selection should be verified by qualified personnel.