- 4 in x 1-1/2 in PVC octagonal conduit box with 4 outlets: (2) 1/2 in and (2) 3/4 in hubs. Commonly used for conduit junctions and fixture outlet points in rigid PVC systems where corrosion resistance and wet-location suitability are important.9 – Loyalty RewardsClick the image to back order this item from the product page
PVC FSC conduit outlet box · 1-gang · 1/2 in hubs top and bottom · lug mount · Royal RFSC10
Single-gang PVC FSC conduit outlet box with 1/2 in hubs in a top-and-bottom entry layout for exposed PVC conduit runs. Commonly used where a weather-resistant, non-metallic device box is needed with rigid PVC conduit; confirm cover and device compatibility before ordering.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory9 – Loyalty RewardsClick the image to back order this item from the product page- Edmonton Stock: 40
PVC Junction Box · 4 x 4 x 2 in · Gasketed Cover, 25.4 cu in · Westlake Pipe & Fittings RJB442
4 x 4 x 2 in (101.6 x 101.6 x 50.8 mm) PVC junction box with gasketed cover, 25.4 cu in capacity, and threaded brass inserts for rigid PVC conduit systems. Suitable for indoor or outdoor installations where a non-metallic, corrosion-resistant box is required, including damp, washdown, and corrosive areas when installed with compatible fittings.
7 – Loyalty RewardsClick the image to back order this item from the product page- Edmonton Stock: 18
PVC Junction Box · 5 x 5 x 2 in · Gasketed Cover · Westlake Pipe & Fittings JB552
5 x 5 x 2 in (127 x 127 x 51 mm) PVC junction box for rigid PVC conduit systems, supplied with cover, gasket, and screws. Approximate 38.7 cu in capacity with NEMA 1, 2, 3, 3R, 4, 4X, 6P, 12 and 13 ratings, commonly used where corrosion resistance and weather protection are required.
18 – Loyalty RewardsClick the image to back order this item from the product pagePVC Junction Box · 4 x 4 x 4 in · Gasketed PVC Enclosure · Westlake Pipe & Fittings RJB444
4 x 4 x 4 in PVC junction box with gasketed cover, threaded brass inserts, and approximately 47.5 cu in internal volume for rigid PVC conduit runs. Suitable for indoor or outdoor use where a non-metallic enclosure is needed for moisture, dust, or corrosive conditions.
Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory15 – Loyalty RewardsClick the image to back order this item from the product page- Edmonton Stock: 3
PVC Junction Box · 6 x 6 x 4 in · Gasketed NEMA 4X Enclosure · Westlake Pipe & Fittings RJB664
Gasketed PVC junction box with 6 x 6 x 4 in dimensions, 139.5 cu in capacity, and threaded brass inserts for rigid PVC conduit installations. CSA and UL listed, with NEMA 1/2/3/4/4X/12/13 ratings for indoor, outdoor, wash-down, and corrosive environments.
25 – Loyalty RewardsClick the image to back order this item from the product pagePVC Junction Box · 8 x 8 x 4 in · Gasketed Cover, 258.6 cu in · Westlake Pipe & Fittings RJB884
8 x 8 x 4 in (203 x 203 x 102 mm) PVC junction box with gasketed cover for rigid PVC conduit systems. Westlake Pipe & Fittings RJB884 provides 258.6 cu in capacity and is commonly used where electricians need a non-metallic box for wet-location or corrosive-area conduit runs.
Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory43 – Loyalty RewardsClick the image to back order this item from the product pagePVC Junction Box · 12 x 12 x 4 in · Gasketed NEMA 4X Enclosure · Westlake Pipe & Fittings RJB12124
Gasketed PVC junction box for rigid PVC conduit systems, sized 12 x 12 x 4 in (305 x 305 x 102 mm) with approximately 578 cu in capacity. Commonly used where corrosion resistance and weather protection matter, including outdoor and washdown-adjacent installations; actual suitability depends on conduit entry method, sealing, and local electrical code.
Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory114 – Loyalty RewardsClick the image to back order this item from the product pagePVC Junction Box · 12 x 12 x 6 in · Gasketed NEMA 4X PVC enclosure · Westlake Pipe & Fittings RJB12126
12 x 12 x 6 in (305 x 305 x 152 mm) PVC junction box with gasketed cover for rigid PVC conduit systems. Westlake Pipe & Fittings RJB12126 provides 864.6 cu in capacity, threaded brass inserts and screws, and NEMA 1/2/3/4/4X protection for indoor or outdoor commercial, industrial, and corrosive-area installations.
Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory124 – Loyalty RewardsClick the image to back order this item from the product page- Edmonton Stock: 50
PVC FD conduit outlet box · 1-gang deep blank · no hub, lug mount · Royal RFD
1-gang deep blank FD PVC conduit outlet box for rigid PVC conduit systems, with no factory hub openings so entries can be drilled on site to suit the application. Commonly used where hub location flexibility matters; actual suitability depends on box fill, fittings, and local electrical code.11 – Loyalty RewardsClick the image to back order this item from the product page- Edmonton Stock: 5
FS Conduit Outlet Box · 1-Gang · 1/2 in Hub · PVC F Series · Royal RFS10
Single-gang PVC FS conduit outlet box for 1/2 in PVC rigid conduit runs. This F Series box provides approximately 17 cu in of wiring space and lug mounting for exposed conduit installations in commercial, residential, industrial, and institutional applications.8 – Loyalty RewardsClick the image to back order this item from the product page- Edmonton Stock: 3
FS conduit outlet box · 1-gang, 3/4 in hub · PVC lug-mount, grey · Royal RFS15
Single-gang FS PVC conduit outlet box with 3/4 in hub for exposed wiring runs using rigid PVC conduit. Commonly used where a device or splice point is needed on surface-mounted conduit, with approximately 16.3 to 17 cu in capacity depending on source listing.8 – Loyalty RewardsClick the image to back order this item from the product page- Edmonton Stock: 2
PVC FSC single-gang outlet box · 3/4 in hubs, 1 top and 1 bottom entry · lug mount, 16.3 cu in · Royal RFSC15
Single-gang PVC FSC outlet box with two 3/4 in conduit entries, configured for 1 top and 1 bottom entry. Commonly used for surface-mounted PVC conduit runs where a compact device box and corrosion-resistant non-metallic construction are required.8 – Loyalty RewardsClick the image to back order this item from the product pageFSS conduit outlet box · 1-gang, (2) 1/2 in hubs, 17.5 cu in, lug mount · PVC, CSA/UL listed · Royal RFSS10
Single-gang F Series PVC conduit outlet box with (2) 1/2 in FSS cable entries, 17.5 cu in capacity, and lug mounting for rigid PVC conduit systems. Commonly used in residential, commercial, industrial, and institutional installations where a non-metallic surface box is required.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory9 – Loyalty RewardsClick the image to back order this item from the product pageFSS PVC conduit outlet box · 1-gang, 2-hole, 3/4 in hubs · lug mount, 17.5 cu in · Royal RFSS15
Single-gang FSS PVC conduit outlet box with two 3/4 in hubs and lug mounting for rigid PVC conduit runs. Listed sources indicate approximately 17.5 cu in box capacity, gray PVC construction, and use with surface conduit installations in residential, commercial, and industrial work.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory8 – Loyalty RewardsClick the image to back order this item from the product page- Edmonton Stock: 4
PVC FD Blank Box · 2-Gang · 4-3/4 in x 4-3/4 in x 3 in · Royal RFD-2
Two-gang FD series blank PVC electrical box for surface-mount conduit installations. This Royal RFD-2 box is a non-metallic blank enclosure with no conduit entries, commonly selected where field-drilled hub locations or custom device layouts are required.18 – Loyalty RewardsClick the image to back order this item from the product page- Edmonton Stock: 10
Blank Cover Plate · 1-Gang PVC · With Gasket · Royal Pipe RBRC15-10
1-gang PVC blank cover plate with gasket for Royal Pipe F Series conduit outlet boxes and related PVC box applications. Commonly used to close an unused device opening in damp or outdoor box installations where a gasketed cover is required.3 – Loyalty RewardsClick the image to back order this item from the product pageWeatherproof 1-Gang Plunger Switch Cover · PVC · Grey · Royal RVPT15/10
Single-gang weatherproof plunger-style switch cover for rigid PVC conduit box installations. PVC construction, grey finish, and CSA/UL approval make it suitable for outdoor or damp-location box cover applications where a plunger switch cover style is required.
Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory17 – Loyalty RewardsClick the image to back order this item from the product pageWeatherproof Toggle Switch Cover · 1-Gang PVC · Red External Lever · Royal RVSC15/10
1-gang weatherproof PVC cover plate for a toggle switch, designed for use with compatible PVC device boxes in wet or damp locations. The red external lever provides switch operation through the cover while helping maintain a weather-resistant assembly when installed with the correct gasket and box.
Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory15 – Loyalty RewardsClick the image to back order this item from the product pageWeatherproof duplex receptacle cover plate · 1-gang · white PVC flip cover · Royal RWDR15/10
1-gang weatherproof PVC cover plate for a duplex receptacle in outdoor or damp-location box installations. White flip-cover design commonly used with PVC weatherproof boxes where a listed weather-resistant cover is required when the receptacle is not in use.
Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory7 – Loyalty RewardsClick the image to back order this item from the product pageWeatherproof GFCI Cover Plate · 1-Gang · PVC · Royal RWGF15/10
1-gang weatherproof PVC cover plate for GFCI/Decora-style receptacle installations on compatible Royal or Kraloy PVC boxes. Commonly used for outdoor and damp-location device protection where a gasketed weatherproof cover is required.
Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory7 – Loyalty RewardsClick the image to back order this item from the product pageWeatherproof 1-Gang Toggle Switch Cover · PVC · Grey · Royal RWTG15/10
Single-gang weatherproof toggle switch cover for PVC FS/FD-style device boxes in outdoor or damp locations. PVC construction helps resist corrosion, and gasketed weatherproof covers are commonly used where a standard indoor plate is not suitable.
Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory7 – Loyalty RewardsClick the image to back order this item from the product pageWeatherproof Blank Cover · 2-Gang Flat PVC with Gasket · Gray · Royal Pipe Systems RBRC20-2
2-gang flat weatherproof blank cover for PVC box installations, supplied with gasket and intended for outdoor or damp-location box closures where no device opening is required. Commonly used to seal unused box faces on rigid PVC conduit systems in residential, commercial, and industrial installations.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory5 – Loyalty RewardsClick the image to back order this item from the product pageWeatherproof double-toggle cover · 2-gang PVC · threaded mount with gasket · Royal Pipe RVSC20-2
2-gang weatherproof PVC cover for two toggle switches, typically used on outdoor or damp-location PVC box installations. Threaded screw-on style with gasket; commonly selected where corrosion resistance and a non-metallic cover are preferred.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory23 – Loyalty RewardsClick the image to back order this item from the product pageWeatherproof PVC Cover Plate · 2-Gang · 1 Plunger Switch + 1 Decora/GFCI Flip Lid · Royal RVSRC20-2
2-gang weatherproof PVC cover plate for one plunger-style switch opening and one Decora/GFCI opening with flip lid. Commonly used on exterior PVC box installations in residential, commercial, and institutional work where a weatherproof device cover is required.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory28 – Loyalty RewardsClick the image to back order this item from the product pagePVC double-gang cover plate · 2 toggle switch openings · F Series flat cover · Royal Pipe Systems RTSC20-2
Non-metallic F Series double-gang flat cover plate with two toggle switch openings for Royal Pipe Systems PVC box installations. Commonly used where a 2-gang PVC box needs two standard toggle devices in corrosive or non-metallic conduit systems.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory3 – Loyalty RewardsClick the image to back order this item from the product page2-Gang PVC Cover Plate · Double Duplex Receptacle · Flat F Series Style · Royal RDRC20-2
2-gang PVC flat cover plate for double duplex receptacle layouts in Royal rigid PVC box and fitting systems. Commonly used where a non-metallic cover is preferred for corrosion resistance in damp or outdoor-adjacent installations; verify box, gasket and device compatibility before ordering.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory3 – Loyalty RewardsClick the image to back order this item from the product pageWeatherproof Blank Cover · 3-Gang PVC Plate with Gasket · For F-Series Box Applications · Royal Pipe RBRC20-3
3-gang PVC blank cover for F-Series weatherproof box applications, supplied with gasket for closing unused device openings in outdoor or damp-location box assemblies. Commonly used where a triple-gang PVC box needs a sealed blank face; verify box series and cover compatibility before ordering.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory6 – Loyalty RewardsClick the image to back order this item from the product pagePVC Cover Plate · 3-Gang · 3 Toggle Openings · Royal RTSC20-3
3-gang PVC cover plate with three toggle switch openings for compatible Royal rigid PVC conduit device boxes. Commonly used where corrosion resistance and non-metallic box systems are required in commercial, industrial, and washdown-adjacent installations.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory7 – Loyalty RewardsClick the image to back order this item from the product pagePVC device cover · 3-gang · 1 toggle and 2 duplex openings · Royal RTSDC20-3
3-gang PVC device cover with 1 toggle switch opening and 2 duplex receptacle openings for PVC box installations. Commonly used where a non-metallic, corrosion-resistant cover is needed on compatible PVC device boxes in residential, commercial, or industrial environments.Available to Order | Typically Arrives in 1 - 3 Weeks Ships from Abbotsford BC Factory7 – Loyalty RewardsClick the image to back order this item from the product page
Quick Decision Summary
- Choose PVC electrical boxes where corrosion resistance, non-metallic construction, and compatibility with PVC conduit systems matter.
- Match the box style to the job - device boxes for switches and receptacles, junction boxes for splices, and weather-exposed enclosures only where the product is listed for that environment.
- Check box volume, conductor count, fitting entry size, cover style, and mounting method before ordering.
- PVC boxes are common in residential, light commercial, agricultural, and damp or corrosive areas, but they are not a universal substitute for steel boxes.
- For Canadian work, always confirm the selected box, fittings, support method, and installation details meet the applicable code and local inspection requirements.
PVC electrical boxes are used where electricians want a non-metallic box that resists moisture, many chemicals, and rust while pairing cleanly with PVC conduit or other approved non-metallic wiring methods. In practice, the right choice depends less on the word PVC and more on the actual job conditions: indoor or outdoor exposure, conduit or cable entry, number of conductors, device depth, cover requirements, and whether the box will be surface mounted, cast into concrete, or concealed in finished construction. For trade buyers, the main buying mistake is ordering by rough appearance instead of by box function and entry configuration.
What Are PVC Electrical Boxes?
PVC electrical boxes are non-metallic outlet, device, junction, and enclosure boxes made for containing splices, supporting wiring devices, and providing termination space in electrical systems. They are commonly used with PVC conduit systems and in some cases with non-metallic sheathed cable where the box design is intended for that wiring method. Compared with steel boxes, PVC boxes do not rust and do not require bonding in the same way a metal box does, but they must still be selected and installed correctly for conductor fill, support, environmental exposure, and mechanical protection. The exact style matters: a one-gang device box, a FS or FD style weather box, and a plain junction box solve different problems.
Where Are PVC Electrical Boxes Used?
PVC electrical boxes are widely used in residential basements, garages, utility spaces, agricultural buildings, car washes, food-related washdown-adjacent areas where the specific enclosure is suitable, and outdoor conduit runs where corrosion resistance is important. They are also common anywhere PVC conduit is already the standard raceway, such as slab work, masonry walls, and many service yard or site installations. In finished indoor spaces, electricians may use non-metallic device boxes for switches and receptacles where permitted and appropriate. In exposed industrial areas with high impact risk, high heat, or where metal raceway systems are standard, steel or other enclosure types may still be the better fit.
How To Choose PVC Electrical Boxes
Start with the wiring method. If the installation is PVC conduit, choose a box with the right hub or knockout arrangement and enough room for conductors and fittings. If the installation is for switches or receptacles in framed walls, confirm the box is intended for that device application and wall construction. Next, check box size and depth. Shallow boxes can create crowding once larger conductors, device yokes, pigtails, and connectors are added. Then review environment: dry location, damp location, wet location, direct sunlight, washdown, or corrosive exposure. Also verify cover style, gasket needs, mounting ears or brackets, and whether the box must support a device, luminaire, or only splices. If the job involves larger conduit entries or multiple bends, a larger junction box often saves labour compared with trying to force pulls and splices into a tight enclosure.
Trade Rules Of Thumb
As a practical rule, size up the box when you expect more than a simple pass-through or one device with minimal splicing. Electricians usually regret boxes that are too small far more often than boxes that are one size larger. For conduit systems, leave enough working room for conductors to enter without sharp crowding at hubs or connectors. For device boxes, deeper boxes generally make terminations easier when using GFCI devices, dimmers, smart controls, or heavier gauge conductors. For outdoor work, treat cover selection as part of the box selection, not an afterthought. For corrosive or wet areas, use a complete system approach: box, cover, gasket, hubs, conduit, and fittings should all suit the environment. These are practical rules of thumb only and do not replace code calculations or product listing requirements.
Sizing Guidelines
Box sizing should be based on conductor count, conductor size, internal devices, fittings, and splice space, not just on whether the conductors can physically be pushed inside. A typical buying approach is to first identify the number of insulated conductors entering the box, then account for device yokes, internal clamps if present, bonding conductors where applicable, and any special terminations. Junction boxes used as pull or splice points should also be sized with conductor bending space in mind, especially as conductor size increases. For conduit boxes, confirm hub trade size and the number of entries needed. If the installation may expand later, a slightly larger box can reduce rework. Final sizing should always follow the applicable Canadian Electrical Code requirements, manufacturer instructions, and local authority interpretation.
Common Installation Practices
Common practice is to mount PVC boxes square and solid so conduit entries line up without stress on hubs or adapters. Installers typically dry-fit conduit runs before final solvent cementing to avoid misalignment. Where boxes are exposed outdoors, covers and gaskets are selected together and fasteners are tightened evenly to maintain the seal without cracking the enclosure. In framed wall work, non-metallic device boxes are usually positioned to suit finished wall depth and device alignment. In masonry or concrete work, electricians often choose box styles designed for that construction method rather than adapting a general-purpose box. It is also common to leave enough conductor length for clean terminations while avoiding excessive stuffing that makes device installation difficult.
Common Mistakes
The most common mistake is underestimating box fill. A box that looks acceptable during rough-in can become a problem once splices, larger devices, and covers are added. Another frequent issue is using an indoor box or cover in a damp or wet location. Electricians also run into trouble when mixing box styles and fittings that do not properly match the conduit system. Over-tightening screws into plastic bodies can crack ears, covers, or mounting points. In outdoor work, poor support or conduit strain can distort the box over time. Another avoidable problem is assuming all plastic boxes are interchangeable; in reality, gang style, depth, mounting method, entry pattern, and environmental listing all matter.
Brand Comparisons
In the Canadian market, Ipex, Royal, and Carlon are commonly recognized names in non-metallic boxes and PVC raceway-related products. Royal Pipe, now associated with WestLake branding in many channels, is a practical choice for standard PVC system work and is often selected where buyers want a familiar Canadian-market option for conduit and box compatibility. Ipex is widely specified and commonly encountered on projects where matching an existing installed system is important. Carlon is also well known, especially where contractors are cross-shopping non-metallic box and conduit accessories. In many standard applications, these brands are compared on availability, system compatibility, box style selection, and contractor preference more than on dramatic performance differences. If a site already uses one system heavily, matching that installed brand family may simplify fittings, appearance, and procurement. Where Royal Pipe products meet the job requirements, they are a sensible alternative for many everyday applications.
Related Products
PVC electrical boxes are commonly purchased with PVC conduit, male adapters, couplings, terminal adapters, locknuts, bushings, weatherproof covers, device covers, gaskets, solvent cement, straps, and support hardware. Depending on the application, buyers may also need switches, receptacles, GFCI devices, blank covers, extension rings where available for the box family, and approved connectors for cable-entry styles. For outdoor or washdown-adjacent work, it is worth reviewing the full enclosure assembly rather than ordering the box alone.
Frequently Asked Questions
Are PVC electrical boxes suitable for outdoor use?
Many are, but not all. Outdoor suitability depends on the specific box, cover, gasket, and listing for wet or damp locations. A plastic box by itself does not automatically mean it is ready for exposed outdoor service.
Can PVC electrical boxes be used with metal conduit?
They can be in some applications if the fittings and installation method are appropriate, but electricians should review bonding, mechanical protection, and system compatibility carefully. In many jobs, PVC boxes are most straightforward when used as part of a non-metallic conduit system.
Do PVC boxes need bonding?
The box itself is non-metallic, so it is treated differently from a metal box, but circuit bonding requirements still depend on the wiring method and equipment served. Always follow the applicable code rules for the full circuit, not just the box material.
How do I know if a box is large enough?
Count conductors, devices, fittings, and splice space requirements, then verify the box volume and layout are suitable. If the box will contain larger devices such as GFCIs, dimmers, or smart controls, extra depth is often helpful.
When should I choose a steel box instead of PVC?
Steel is often preferred where the installation needs greater mechanical strength, where metal raceway is standard, where grounding and bonding practices favour metal enclosures, or where the environment involves heat or abuse that makes plastic less suitable.
Is one PVC box brand always better than another?
Not usually. For many standard jobs, the better choice is the brand that matches the installed system, has the right box style and fittings, and is available when you need it. Product family compatibility and jobsite preference often matter more than brand reputation alone.