- Factory Stock in Ontario
- 46 In Ontario Factory Warehouse As Of Aug 6th 202620 – Loyalty Rewards
- Factory Stock in Ontario
Definite Purpose Contactor · 2-Pole 20A 2NO 24V AC Coil · Lug Terminals with Dual Quick Connect · Noark Electrical EX9CKT20B20B7
EX9CKT20B20B7
25 In Ontario Factory Warehouse As Of Aug 6th 202620 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 2 Pole · 25A · 120V Coil · Lug Terminals with Dual QCT · Noark Electric EX9CKT25B20G7
EX9CKT25B20G7
55 In Ontario Factory Warehouse As Of Aug 6th 202622 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 30A · 120V Coil · Lug Terminals with Dual Quick Connect · Noark Electrical EX9CKT30B10G7
EX9CKT30B10G7
6 In Ontario Factory Warehouse As Of Aug 6th 202617 – Loyalty RewardsDefinite Purpose Contactor · 30A 2-Pole 2NO 120V Coil · Lug Terminals with Dual Quick Connects · Noark Electrical EX9CKT30B20G7
EX9CKT30B20G7
Available to Order | Contact Us to Verify ETA22 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 2-Pole 40A · 120V Coil, 2NO Lug Terminals · Noark Electrical EX9CKT40B20G7
EX9CKT40B20G7
270 In Ontario Factory Warehouse As Of Aug 6th 202630 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 2-Pole 40A · 24V AC Coil, Lug Terminals, 2NO · Noark Electrical EX9CKT40B20B7
EX9CKT40B20B7
216 In Ontario Factory Warehouse As Of Aug 6th 202630 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 20A 3-Pole 3NO 120V Coil · Lug Terminals · Noark Electrical EX9CKT20B30G7
EX9CKT20B30G7
68 In Ontario Factory Warehouse As Of Aug 6th 202633 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 20A · 3 Pole 3NO · 208/240V AC Coil, Lug Terminals · Noark Electrical EX9CKT20B30XU7
EX9CKT20B30XU7
21 In Ontario Factory Warehouse As Of Aug 6th 202633 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 20A · 3 Pole 3NO · 24V AC Coil Lug Terminals · Noark Electrical EX9CKT20B30B7
EX9CKT20B30B7
12 In Ontario Factory Warehouse As Of Aug 6th 202633 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 25A 3-Pole 3NO 120V Coil · Lug Terminals · Noark Electrical EX9CKT25B30G7
EX9CKT25B30G7
32 In Ontario Factory Warehouse As Of Aug 6th 202637 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 25A · 3 Pole 3NO, 208/240V Coil, Lug Dual QC · Noark Electrical EX9CKT25B30XU7
EX9CKT25B30XU7
48 In Ontario Factory Warehouse As Of Aug 6th 202637 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 25A · 3 Pole 3NO 24V Coil Lug Terminals · Noark Electrical EX9CKT25B30B7
EX9CKT25B30B7
70 In Ontario Factory Warehouse As Of Aug 6th 202637 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 3 Pole · 30A · 3NO · 120V AC Coil · Lug Terminals · Noark Electrical EX9CKT30B30G7
EX9CKT30B30G7
464 In Ontario Factory Warehouse As Of Aug 6th 202637 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 3-Pole 30A 3NO · 208/240V Coil, Lug Dual Terminals · Noark Electrical EX9CKT30B30XU7
EX9CKT30B30XU7
150 In Ontario Factory Warehouse As Of Aug 6th 202637 – Loyalty RewardsDefinite Purpose Contactor · 30A · 3 Pole 3NO · 600V Coil · Lug Terminals · Noark Electrical EX9CKT30B30Y7
EX9CKT30B30Y7
Available to Order | Contact Us to Verify ETA37 – Loyalty RewardsDefinite Purpose Contactor · 40A, 3-Pole, 3NO, 120V Coil, Screw Terminals · HVAC and Motor Control · Noark Electrical EX9CKT40A30G7
EX9CKT40A30G7
Available to Order | Contact Us to Verify ETA43 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 40A · 3 Pole 3NO · Lug Terminals, 120V Coil · Noark Electrical EX9CKT40B30G7
EX9CKT40B30G7
258 In Ontario Factory Warehouse As Of Aug 6th 202643 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 40A · 3-Pole 3NO · 208/240V 50/60 Hz Coil, Lug Terminals · Noark Electrical EX9CKT40B30XU7
EX9CKT40B30XU7
83 In Ontario Factory Warehouse As Of Aug 6th 202643 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 3 Pole 3NO 40A 24V AC Coil · Screw Terminals · Noark Electrical EX9CKT40A30B7
EX9CKT40A30B7
22 In Ontario Factory Warehouse As Of Aug 6th 202643 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 40A · 3 Pole 3NO · 24VAC Coil with Lug Terminals · Noark Electrical EX9CKT40B30B7
EX9CKT40B30B7
25 In Ontario Factory Warehouse As Of Aug 6th 202643 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 50A · 3-Pole 3NO, 120V Coil, Lug Terminals · Noark Electrical EX9CK50B30G7
EX9CK50B30G7
47 In Ontario Factory Warehouse As Of Aug 6th 202677 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 50A · 3-Pole 3NO · Lug Terminals, 220V AC Coil · Noark Electrical EX9CK50B30M7
EX9CK50B30M7
120 In Ontario Factory Warehouse As Of Aug 6th 202677 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 50A · 3 Pole 3NO · 24 VAC Coil · Lug Terminals · Noark Electrical EX9CK50B30B7
EX9CK50B30B7
222 In Ontario Factory Warehouse As Of Aug 6th 202677 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 60A · 3-Pole 3NO 120V Coil Lug Terminals · Noark Electrical EX9CK60B30G7
EX9CK60B30G7
254 In Ontario Factory Warehouse As Of Aug 6th 202687 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 60A · 3-Pole 3NO, 220V 50/60 Hz Coil, Lug Terminals · Noark Electrical EX9CK60B30M7
EX9CK60B30M7
57 In Ontario Factory Warehouse As Of Aug 6th 202687 – Loyalty RewardsDefinite Purpose Contactor · 60A · 3-Pole 3NO · Lug Terminals, 240V 50/60 Hz Coil · Noark Electrical EX9CK60B30U7
EX9CK60B30U7
Available to Order | Contact Us to Verify ETA87 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 60A · 3-Pole 3NO · Lug Terminals, 24VAC Coil 50/60Hz · Noark Electrical EX9CK60B30B7
EX9CK60B30B7
15 In Ontario Factory Warehouse As Of Aug 6th 202687 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 75A · 3 Pole 3NO, Lug Terminals, 220V AC Coil · Noark Electrical EX9CK75B30M7
EX9CK75B30M7
43 In Ontario Factory Warehouse As Of Aug 6th 2026164 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 75A 3-Pole 3NO 240V Coil · Lug Terminals · Noark Electrical EX9CK75B30U7
EX9CK75B30U7
8 In Ontario Factory Warehouse As Of Aug 6th 2026164 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 75A · 3-Pole 3NO 24V AC Coil Lug Terminals · Noark Electrical EX9CK75B30B7
EX9CK75B30B7
6 In Ontario Factory Warehouse As Of Aug 6th 2026164 – Loyalty RewardsDefinite Purpose Contactor · 90A · 3 Pole 3NO, 120V AC Coil, Lug Terminals · Noark Electrical EX9CK90B30G7
EX9CK90B30G7
Available to Order | Contact Us to Verify ETA173 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 90A · 3 Pole 3NO Lug Terminals, 220V AC 50/60 Hz Coil · Noark Electrical EX9CK90B30M7
EX9CK90B30M7
170 In Ontario Factory Warehouse As Of Aug 6th 2026173 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 90A · 3-Pole 3NO, 240V 50/60 Hz Coil, Lug Terminals · Noark Electrical EX9CK90B30U7
EX9CK90B30U7
47 In Ontario Factory Warehouse As Of Aug 6th 2026173 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 90A · 3 Pole 3NO, 24V AC Coil, Lug Terminals · Noark Electrical EX9CK90B30B7
EX9CK90B30B7
13 In Ontario Factory Warehouse As Of Aug 6th 2026173 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 30A · 4 Pole 4NO · 120V AC Coil · Screw Terminals · Noark Electrical EX9CKT30A40G7
EX9CKT30A40G7
5 In Ontario Factory Warehouse As Of Aug 6th 202688 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 40A, 4-Pole, 4NO, 120V Coil, Screw Terminals · HVAC and Motor Switching · Noark Electrical EX9CKT40A40G7
EX9CKT40A40G7
22 In Ontario Factory Warehouse As Of Aug 6th 2026101 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 4 Pole 4NO 40A 120V Coil · Lug Terminals · Noark Electrical EX9CKT40B40G7
EX9CKT40B40G7
53 In Ontario Factory Warehouse As Of Aug 6th 2026101 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 40A · 4 Pole 4NO · 24V AC Coil, Lug Terminals · Noark Electrical EX9CKT40B40B7
EX9CKT40B40B7
24 In Ontario Factory Warehouse As Of Aug 6th 2026101 – Loyalty RewardsDefinite Purpose Contactor · 40A, 4-Pole, 4NO, 24V AC Coil, Lug Terminals · Quad Quick Connect · Noark Electrical EX9CKT40B40B7Q
EX9CKT40B40B7Q
Available to Order | Contact Us to Verify ETA101 – Loyalty RewardsAuxiliary Contact Block · 1NO+1NC · Side-Mount for 20–90A Definite Purpose Contactors · Noark Electrical AXFC11
AXFC11
Available to Order | Contact Us to Verify ETA25 – Loyalty Rewards- Factory Stock in Ontario
Surge Protective Device · 1P+N 175V AC 40kA · Signal Contact · Noark U41N40175S
U41N40175S
6 In Ontario Factory Warehouse As Of Aug 6th 2026151 – Loyalty Rewards- Factory Stock in Ontario
Auxiliary Contact Block · 2NO+2NC Microswitch · Side-Mount for Ex9CKT20-40 3P/4P · Noark AXFD22
AXFD22
200 In Ontario Factory Warehouse As Of Aug 6th 202632 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 20A 4NO 120V 50/60 Hz Coil · Screw Terminals with Dual Quick Connect · Noark EX9CKT20A40G7
EX9CKT20A40G7
6 In Ontario Factory Warehouse As Of Aug 6th 202667 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 20A 4NO 24V 50/60 Hz Coil · Screw Terminals with Dual Quick Connect · Noark Electrical EX9CKT20A40B7
EX9CKT20A40B7
4 In Ontario Factory Warehouse As Of Aug 6th 202667 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 25 A · 4NO · Lug Terminals, 120V 50/60 Hz Coil · Noark Electrical EX9CKT25B40G7
EX9CKT25B40G7
6 In Ontario Factory Warehouse As Of Aug 6th 202675 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 30A · 2-Pole 2NO · 24VAC 50/60 Hz Coil · Lug Terminals · Noark Electric EX9CKT30B20B7
EX9CKT30B20B7
1243 In Ontario Factory Warehouse As Of Aug 6th 202622 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 32A · 4NO · 120V 50/60 Hz Coil · Screw Terminals · Noark Electrical EX9CKT32A40G7
EX9CKT32A40G7
21 In Ontario Factory Warehouse As Of Aug 6th 202695 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 32A · 4NO · 24V AC 50/60 Hz Coil · Screw Terminals · Noark Electric EX9CKT32A40B7
EX9CKT32A40B7
8 In Ontario Factory Warehouse As Of Aug 6th 202695 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor · 40 A · 4NO · 24 V AC 50/60 Hz Coil · Screw Terminals · Noark Electric EX9CKT40A40B7
EX9CKT40A40B7
3 In Ontario Factory Warehouse As Of Aug 6th 2026101 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor Ex9CK Lug 50 A 3NO 240V 50/60 Hz
Ex9CK50B30U7
Out of stock77 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor Ex9CKT 20A Lug Dual2NO coil 208-240V 50/60Hz Coil
Ex9CKT20B20XU7
Out of stock20 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor Ex9CKT 30A Screw Dual 2NO 24V 50/60Hz Coil
Ex9CKT30A20B7
Out of stock22 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor Ex9CKT 30A Screw Dual 2NO 120V 50/60Hz Coil
Ex9CKT30A20G7
Out of stock22 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor Ex9CKT 30A Screw Dual 2NO 277V 50/60Hz Coil
Ex9CKT30A20N7
Out of stock22 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor Ex9CKT 30A Screw Dual 2NO 208-240V 50/60Hz Coil
Ex9CKT30A20XU7
Out of stock22 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor Ex9CKT 30A screw Dual 3NO coil 24V50/60Hz
Ex9CKT30A30B7
Out of stock37 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor Ex9CKT 30A screw Dual 3NO coil 120V50/60Hz
Ex9CKT30A30G7
Out of stock37 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor Ex9CKT 30A screw Dual 3NO coil 277V50/60Hz
Ex9CKT30A30N7
Out of stock37 – Loyalty Rewards- Factory Stock in Ontario
Definite Purpose Contactor Ex9CKT 30A screw Dual 3NO coil 208/240V50/60Hz
Ex9CKT30A30XU7
Out of stock37 – Loyalty Rewards
Quick Decision Summary
- Definite purpose contactors are commonly used in HVAC, refrigeration, compressors, unit heaters, pumps and other dedicated equipment where a compact, application-focused contactor is preferred.
- Start with the load type and nameplate data: poles, coil voltage, full load current, locked rotor or motor duty, and any resistive or non-motor load requirements.
- Do not choose by amp rating alone. Motor HP rating, utilization category, duty cycle, enclosure conditions and control voltage all matter.
- For replacement work, matching pole configuration, coil voltage, terminal layout and mounting pattern can save panel modification time.
- Noark and Techspan can be practical options for many standard applications, while matching an installed brand may still be the right choice where fit, approvals or maintenance standardisation matter.
Definite purpose contactors are built for recurring switching duties in equipment such as air conditioners, condensers, refrigeration racks, heat pumps, fans and small motor-driven systems. Compared with larger general-purpose motor control contactors, they are usually selected for a narrower range of applications, with compact footprints and straightforward rating structures that suit OEM panels and service replacement work. For Canadian buyers, the practical selection points are usually coil voltage, number of poles, current and HP rating, terminal style, enclosure conditions and whether the contactor is switching a motor, a resistive heater load or both. Final selection and installation should always follow the equipment nameplate, manufacturer documentation and applicable Canadian Electrical Code requirements.
What Are Definite Purpose Contactors?
Definite purpose contactors are electrically operated switches designed for specific equipment duties rather than broad industrial motor control systems. In practice, they are often found in HVAC and refrigeration equipment where the contactor repeatedly starts and stops compressors, condenser fans, blower motors or electric heat stages. They are typically more compact than many IEC or NEMA contactors and are often chosen where panel space, cost and straightforward replacement are important. Many buyers look first at the amp rating, but a proper selection also considers motor horsepower, inrush characteristics, coil voltage, number of poles, contact arrangement and whether the load is inductive, resistive or mixed.
Where Are Definite Purpose Contactors Used?
These contactors are widely used in rooftop units, condensing units, heat pumps, refrigeration equipment, ice machines, vending equipment, unit heaters, air handlers, pumps, dust collection packages and other OEM assemblies. They are also common in service vans and maintenance stock because many failures in HVAC equipment are resolved by replacing a worn or welded contactor. In commercial buildings, they may appear in packaged mechanical systems, exhaust equipment and electric heating sections. They are less commonly the right choice for heavy industrial motor control centres, frequent reversing duty, complex interlocking or applications that require a broader accessory ecosystem.
How To Choose Definite Purpose Contactors
Start with the equipment nameplate and the old contactor if this is a replacement. Confirm the number of poles required, whether any poles are normally open or normally closed, and the control coil voltage. Then verify the load rating. For motor loads, check the contactor's motor duty or HP rating at the system voltage, not just the listed current. For electric heat or other non-motor loads, confirm the resistive rating. If the application involves a compressor, pay attention to locked rotor conditions and cycling frequency. Also review terminal style, quick-connect versus box lug, mounting dimensions, ambient temperature, enclosure cleanliness and whether the device will be exposed to vibration or moisture. If the contactor is installed in a packaged unit, physical fit and wire routing can be just as important as the electrical rating.
Trade Rules Of Thumb
As a practical rule of thumb, replacement contactors should match the original pole count and coil voltage exactly unless the equipment design is being intentionally revised by a qualified person. Another common trade practice is to leave margin above normal running current where cycling is frequent or ambient temperature is elevated, but that margin does not replace proper rating review. For compressor and fan circuits, technicians often compare both full load current and the equipment's starting behaviour before choosing a substitute. In service work, a physically compatible contactor with equal or better appropriate ratings can reduce downtime, but terminal orientation and cabinet clearance should be checked before ordering. These are practical guidelines only, not code rules.
Sizing Guidelines
Typical sizing starts with the load nameplate. For a motor circuit, identify voltage, phase, full load current and horsepower, then choose a contactor with suitable motor ratings for that duty. For a resistive heater bank, use the resistive current at the operating voltage and confirm the contactor is rated for that non-inductive load. If one contactor is switching both compressor and fan loads, use the combined duty as intended by the equipment design. Coil voltage must match the control circuit exactly, such as 24 V, 120 V or other common control voltages. Where exact replacement data is unclear, do not rely on visual similarity alone. Review the equipment wiring diagram and manufacturer literature. Overcurrent protection, overload protection and conductor sizing must be coordinated separately under the applicable design and code requirements.
Common Installation Practices
In the field, installers usually verify line and load orientation, torque terminals to the manufacturer's values, inspect for overheated conductors and replace damaged push-on terminals when changing a contactor. It is also common practice to inspect the control transformer, thermostat circuit, pressure switches and capacitor condition when a contactor has failed, because the contactor may be a symptom rather than the root cause. In packaged equipment, keeping conductors neatly routed away from moving parts and hot surfaces helps reduce nuisance failures. Before energising, confirm the armature moves freely, the coil is correct for the control circuit and the enclosure is suitable for the environment. Lockout, verification of absence of voltage and safe work procedures are essential.
Common Mistakes
One of the most common mistakes is replacing a contactor based only on the printed amp number without checking horsepower or load type. Another is installing the wrong coil voltage, especially when 24 V control circuits are confused with line-voltage coils. Buyers also run into trouble when they overlook terminal style, mounting footprint or cabinet depth, turning a quick replacement into a panel modification job. In HVAC service, reusing heat-damaged female quick-connects can lead to repeat failures. It is also a mistake to assume every definite purpose contactor is interchangeable across brands. Even when ratings look similar, approvals, dimensions, auxiliary contact options and expected service life can differ.
Brand Comparisons
Noark and Techspan are practical brands to consider for many standard definite purpose contactor applications, especially where buyers want straightforward replacement options and value-conscious stocking for service work or OEM builds. Noark is commonly cross-shopped where buyers want a recognised alternative in control gear with broad everyday applicability. Techspan can be a sensible option where the priority is a functional replacement for common HVAC and equipment duties. In the wider market, Square D, Telemecanique, ABB, Schneider Electric, Eaton and Lovato are familiar names, and matching an installed brand may be the right move when mounting, accessory compatibility, engineering standards or maintenance preferences are already established. Brand choice should be based on fit, ratings, approvals, support and consistency with the equipment being serviced, not only on name recognition.
Related Products
Buyers looking at definite purpose contactors often also need overload relays where applicable, control transformers, terminal blocks, time delay relays, motor run capacitors, disconnect switches, fuses, supplementary protectors, enclosure heaters, DIN rail components and replacement wire terminals. For HVAC and refrigeration service, common companion items include pressure controls, fan relays, crankcase heater controls and service disconnects. If the application is moving beyond simple switching duty, it may be worth comparing IEC contactors, manual motor starters or enclosed starters instead of forcing a definite purpose contactor into a job it was not intended to handle.
Frequently Asked Questions
What is the difference between a definite purpose contactor and an IEC contactor?
A definite purpose contactor is usually selected for a narrower set of equipment duties, often in HVAC or OEM equipment, with compact construction and simpler option sets. An IEC contactor is generally part of a broader motor control system with more accessory and coordination options. The right choice depends on the application, not just the physical size.
Can I replace any HVAC contactor with one that has the same amp rating?
No. You should also match coil voltage, pole count, motor or resistive duty rating, mounting arrangement and terminal style. A contactor with the same amp number may still be unsuitable if the horsepower rating, control voltage or physical fit is wrong.
Are 2-pole and 3-pole definite purpose contactors interchangeable?
Not as a general rule. The number of poles must suit the circuit design and the equipment wiring diagram. Some equipment uses only two switched poles, while other systems require three. Substituting a different pole arrangement without proper design review can create unsafe or non-compliant operation.
What coil voltage should I choose?
Choose the coil voltage that matches the control circuit exactly. Common examples include 24 V and 120 V, but other values are also used. Always verify from the schematic, nameplate or existing component markings before ordering.
When should I match the existing brand instead of cross-referencing to another brand?
Matching the existing brand is often sensible when space is tight, mounting holes are fixed, approvals matter to the equipment package, or the maintenance team wants standardisation across a site. A cross-reference can still be a good option when the replacement has the correct ratings, fit and approvals for the job.
Do definite purpose contactors include overload protection?
Usually no. A contactor is primarily a switching device. Overload protection, short-circuit protection and branch circuit protection are separate design considerations and must be selected to suit the equipment and applicable code requirements.





















































